DELTA FAUCET 14478-RBSHL

Leland 1400 Single Lever Tub and Shower Faucet

Pukapuka Tohutohu

1. Kupu Whakataki

This manual provides detailed instructions for the installation, operation, and maintenance of your DELTA FAUCET Leland 1400 Single Lever Tub and Shower Faucet. Please read all instructions carefully before beginning installation or use to ensure proper function and safety.

The Leland 1400 series features a single lever design for temperature and flow control, a Monitor Scald-Guard valve to maintain water temperature, and a Touch-Clean showerhead for easy maintenance. This product is constructed from solid brass for durability and reliability.

2. Nga korero haumaru

  • Whakawetohia i nga wa katoa te puna wai matua i mua i te whakauru, te mahi ranei i te korere.
  • Me mau ngā taputapu tiaki whaiaro e tika ana, pērā i ngā mōhiti haumaru, i te wā e tāuta ana.
  • Mena kaore koe i te tino mohio mo tetahi waahanga o te mahi whakaurunga, me toro atu ki tetahi tohunga paipa.
  • Me whakarite kia mau nga hononga katoa kia kore ai e pakaru.
  • Do not use harsh chemicals or abrasive cleaners on the faucet finish, as this may damage the product and void the warranty.

3. Ihirangi mokete

Verify that all components are present before beginning installation. The package should contain:

  • Single lever tub and shower faucet trim
  • Showerhead with Touch-Clean nozzles
  • Tub spout with pull-up diverter
  • Ngā taputapu whakairi me ngā hiri
  • Nga tohutohu whakaurunga

Note: The rough-in valve (Monitor Scald-Guard) is typically sold separately and must be installed according to its specific instructions.

4. Tatūnga me te Tāuta

This section outlines the general steps for installing the Leland 1400 tub and shower faucet trim. Refer to the rough-in valve's specific instructions for valve body installation.

  1. Whakapaia te Rohe Tāuta: Ensure the rough-in valve is securely installed in the wall and the water supply is turned off. Clear any debris from the pipes.
  2. Install the Showerhead: Apply plumber's tape to the threaded end of the shower arm extending from the wall. Thread the showerhead onto the shower arm and hand-tighten. Use a wrench to tighten an additional 1/4 to 1/2 turn. Do not overtighten.
  3. Tāutahia te Puku o te Tāpu: The tub spout is a pull-up diverter type. Depending on your rough-in plumbing, it will either thread directly onto a pipe extending from the wall or secure with a set screw onto a smooth copper pipe. Ensure the spout is flush against the wall and sealed properly.
  4. Install the Faucet Handle Trim: Follow the instructions provided with your specific rough-in valve for installing the escutcheon (wall plate) and the single lever handle. This typically involves securing the escutcheon to the valve body and then attaching the handle.
  5. Whakamātautau mō ngā turuturu: Once all components are installed, slowly turn on the main water supply. Check all connections for leaks. If leaks are present, turn off the water, tighten the connections, and retest.
Leland 1400 Single Lever Tub and Shower Faucet installed

Image 1: The Leland 1400 Single Lever Tub and Shower Faucet, showcasing its design and components. This image illustrates the installed faucet, including the showerhead, single lever handle, and tub spout.

5. Nga Tohutohu Whakahaere

The Leland 1400 faucet features a single lever for controlling both water temperature and flow.

  • Turning On/Off and Adjusting Flow: Lift the single lever handle to turn on the water and increase flow. Push the lever down to decrease flow and turn off the water.
  • Te Whakarereke i te Mamahana: Rotate the single lever handle left (counter-clockwise) for hotter water and right (clockwise) for colder water. The Monitor Scald-Guard valve will help maintain a consistent temperature within +/-3 degrees Fahrenheit, preventing sudden temperature changes.
  • Diverting Water to Shower: To divert water from the tub spout to the showerhead, pull up the knob on the top of the tub spout. Push the knob down to return water flow to the tub spout.

6. Tiaki

Mā te horoi me te tiaki i ia wā ka roa te ora me te mahi tino pai o tō taputapu.

  • Cleaning the Faucet Finish: Horoia te kōrere ki te ngohengohe, damp cloth. For stubborn spots, use a mild soap and water solution. Rinse thoroughly and dry with a soft cloth. Avoid abrasive cleaners, harsh chemicals, or polishes, as these can damage the finish.
  • Cleaning the Touch-Clean Showerhead: The showerhead features Touch-Clean nozzles. To remove mineral buildup, simply rub the rubber nozzles with your finger or a soft brush. This helps maintain spray performance.
  • Te Tiaki i te Kāri: If you experience consistent drips or significant changes in water flow/temperature control, the pressure balance cartridge may need servicing or replacement. Refer to the rough-in valve's manual or contact customer support for guidance.

7. Te Raru

If you encounter issues with your Leland 1400 faucet, refer to the following common solutions:

Raruraru Take pea Rongoā
Low water flow from showerhead or tub spout Mineral buildup in showerhead nozzles; partially closed shut-off valves; debris in cartridge. Clean Touch-Clean nozzles; ensure shut-off valves are fully open; clean or replace cartridge.
He wera rawa, he makariri rawa rānei te pāmahana wai Temperature limit stop incorrectly set on valve cartridge; issues with water heater. Adjust the temperature limit stop on the valve cartridge (refer to valve manual); check water heater settings.
Faucet drips or leaks Kāritere kua tawhito; hononga koretake. Replace the cartridge; tighten connections.
Diverter not working properly He para i roto i te pūnaha whakawhiti; kua pakaru te hiri whakawhiti. Clean or replace the diverter mechanism in the tub spout.

If these solutions do not resolve the issue, contact DELTA FAUCET customer support or a qualified plumber.

8. Whakatakotoranga

Āhuahira Whakatakotoranga
Waitohu DELTA FAUCET
Tau tauira 14478-RBSHL-PARENT
Rauemi Parahi
Rauemi Kakau Parahi
Momo Whakaeke Maunga Taiepa
Nga Waahanga kei roto Pupu kohu
Momo Pataata Single function pressure balance cartridge (Monitor Scald-Guard)
Tautukunga ADA ture

9. Pūtāhui me te Tautoko

This DELTA FAUCET product is backed by a Lifetime Limited Warranty on the faucet and finish. This warranty covers defects in material and manufacturing for as long as the original consumer purchaser owns the home in which the faucet was first installed.

For warranty claims, technical assistance, or to purchase replacement parts, please contact DELTA FAUCET customer support. Keep your proof of purchase for warranty validation.

For more information, visit the official DELTA FAUCET webpaetukutuku, tirohia rānei ngā tuhinga pūtāhui kei roto i tō hua.

© 2026 DELTA FAUCET. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.