AIDA Imaging HD-NDI-CUBE

AIDA HD-NDI-Cube Full HD NDI|HX IP POV Camera User Manual

Comprehensive instructions for the setup, operation, and maintenance of your AIDA HD-NDI-Cube camera.

Nga Korero Haumaru Nui

  • Me ata panui nga tohutohu katoa i mua i te whakahaere i te taputapu.
  • Puritia tenei pukapuka hei tohutoro a meake nei.
  • Do not expose the camera to moisture or extreme temperatures.
  • Whakamahia anake te urutau hiko kua tohua mō tēnei pūrere.
  • Kaua e ngana ki te wetewete, ki te whakarereke ranei i te kamera. Tukuna atu nga ratonga katoa ki nga kaimahi whai tohu.
  • Ensure proper ventilation around the camera during operation.

Ihirangi mokete

Manatokona kei roto katoa nga mea kei roto i te kete:

  • AIDA HD-NDI-Cube Camera
  • Power Adapter (typically included for operation)
  • Tuhinga (tenei pukapuka)
  • Note: The product listing generically mentions "item" for 'whats_in_the_box'. This manual assumes the camera unit and necessary power supply are included.

Tatūnga

1. Tāutanga Tinana

The AIDA HD-NDI-Cube camera features versatile mounting options for various applications.

  • Identify a suitable location for the camera, ensuring it is stable and has clear line of sight for its intended use.
  • Utilize the top and bottom tripod mounts for secure attachment to tripods, stands, or other mounting hardware.
  • Ensure adequate space for cable connections and ventilation.
AIDA HD-NDI-Cube camera side view

Whakaahua 1: Taha view of the AIDA HD-NDI-Cube camera, showing its compact form factor.

2. Hononga

Connect the camera to power and network for operation.

  1. Hononga Hiko: Connect the provided 12V DC power adapter to the "12VDC" port on the rear of the camera. Plug the adapter into a suitable power outlet. The power indicator LED should illuminate.
  2. Hononga Whatunga: Connect an Ethernet cable from your network switch or router to the "IP/NDI|HX" Ethernet port on the rear of the camera. This connection is essential for NDI|HX video streaming and IP control.
  3. Tāuta Arotahi: If a C/CS mount lens is not pre-installed, carefully attach your desired C/CS mount lens to the camera body. Ensure it is securely fastened.
AIDA HD-NDI-Cube camera rear panel with ports

Figure 2: Rear panel of the AIDA HD-NDI-Cube, showing the IP/NDI|HX Ethernet port and 12VDC power input.

AIDA HD-NDI-Cube camera front and side view me te arotahi

Whakaahua 3: Mua me te taha view of the AIDA HD-NDI-Cube camera, highlighting the C/CS lens mount and SVC port.

Nga Tohutohu Whakahaere

1. Hia Tuatahi

Once connected to power and network, the camera will initiate its startup sequence. The power indicator LED will confirm the device is on.

2. Te uru atu ki te Web UI

The camera features an accessible web user interface (UI) for configuration and control.

  1. Me whakarite kei runga tō rorohiko i te whatunga kotahi me te kāmera.
  2. Use a network scanner tool (e.g., NewTek NDI Tools) to discover the camera's IP address on your network.
  3. Tuwhera a web browser and enter the camera's IP address into the address bar.
  4. Log in using the default credentials (refer to the camera's specific documentation for default username/password, typically "admin" / "admin" or similar).
  5. Mai i te web UI, you can adjust image parameters, network settings, and stream directly to social media platforms.

3. NDI|HX Video Streaming

The AIDA HD-NDI-Cube outputs Full HD 1080p60 NDI|HX video, compatible with NDI-enabled software and hardware.

  • Once the camera is connected to the network, it should be discoverable by NDI-compatible applications (e.g., OBS Studio, vMix, TriCaster).
  • In your NDI receiving software, select the AIDA HD-NDI-Cube as an NDI source.
  • Adjust video settings within your software or the camera's web UI as needed for optimal performance.

Te tiaki

1. Te horoi

  • Ensure the camera is powered off and disconnected from all sources before cleaning.
  • Use a soft, dry cloth to wipe the camera body. Do not use liquid cleaners or aerosols.
  • Mo te arotahi, whakamahia he kakahu horoi mo te arotahi motuhake me te otinga kia kore e pakaru.

2. Whakahoutanga Firmware

Periodically check the AIDA Imaging official website for available firmware updates. Firmware updates can improve performance, add features, and resolve issues.

  • Download the latest firmware from the manufacturer's support page.
  • Follow the specific instructions provided with the firmware update package for installation via the camera's web UI.
  • Tupato: Do not power off the camera during a firmware update, as this may cause irreversible damage.

Raparongoā

No NDI Signal Detected

  • Hononga Whatunga: Ensure the Ethernet cable is securely connected to both the camera and the network switch/router. Verify network activity lights on the camera's Ethernet port.
  • Wāhitau IP: Confirm that the camera and the receiving computer are on the same IP subnet. Incorrect subnet masks can prevent NDI discovery. Access the camera's web UI to verify or adjust network settings. A firmware update may be required to resolve specific IP addressing issues.
  • Software Permissions: If using software like OBS Studio on Windows, ensure the application is run with administrator privileges. Some NDI implementations require elevated permissions to access network streams.
  • Tautuhinga Pātūahi: Check firewall settings on your computer and network to ensure NDI traffic is not being blocked.

Intermittent Signal Loss

  • Pūmautanga Whatunga: Verify the stability and bandwidth of your network. NDI|HX requires a stable network connection.
  • Tikanga taura: Inspect Ethernet cables for damage. Try replacing cables if issues persist.
  • Pūmanawa: Ensure the camera's firmware is up to date. Older firmware versions may have known stability issues.

Kounga Atahanga Kino

  • Lens Focus: Adjust the focus of the C/CS mount lens.
  • Nga Tikanga Rama: Ensure adequate and appropriate lighting for your scene.
  • Web Tautuhinga UI: Uru ki te kamera web UI to adjust image parameters such as exposure, white balance, and color temperature.
  • Topa Mamati: Avoid excessive digital zoom, as it can degrade image quality on 1080p cameras. Consider variable focus lens replacements for optical zoom capabilities.

Whakatakotoranga Hangarau

ĀhuahiraWhakatakotoranga
WaitohuAIDA Whakaahua
Tau tauiraHD-NDI-CUBE
Momo Pūoko1/3'' Progressive Scan CMOS
Whakataunga Hopu Ataata1080p (Katoa HD)
Whakatau Ataata Whaihua2.07 MP
Hangarau HonongaEthernet (NDI|HX)
Maunga ArotahiMaunga C/CS
Te Roa Arotahi Morahi1 Millimeter (Lens dependent)
Roa Arotahi Morahi4 Millimeters (Lens dependent)
Aperture Morahi3 f (Lens dependent)
Momo ArotahiFixed Focus (Lens dependent)
Tauwehe PukaKiato
TaePango
Ngā āhuatangaLow Light Capability
Whakapumau AtahangaKao
Taumata Atete WaiEhara i te wai ātete
Hōputu Ororongo TautokohiaPCM, MP3, AAC
Hōputu Hopu AtaataASF
Hōputu Atahanga TautokoJPEG
Ahuatanga Atahanga16:9
Tautuhinga White BalanceAunoa
Momo Mana WhakaaturangaPapatono (P)
Aratau WhakapupuriManual, Automatic, Program (P)
Pūrere HototahiPC Mac ranei
UPC686091739809

Pūtāhui me te Tautoko

Nga korero Whakaputanga

AIDA Imaging products are typically covered by a manufacturer's warranty. For specific warranty terms and conditions, including duration and coverage details, please refer to the warranty card included with your product or visit the official AIDA Imaging webpae.

Puritia to tohu hoko mo nga kereme whakamana.

Tautoko Kiritaki

For technical assistance, troubleshooting beyond this manual, or service inquiries, please contact AIDA Imaging customer support.

  • Visit the official AIDA Imaging webpae mo nga rauemi tautoko, FAQ, me nga korero whakapā.
  • Have your product model number (HD-NDI-CUBE) and serial number ready when contacting support.