VEVOR SS-003

VEVOR Under Sink RO System SS-003 Instruction Manual

Brand: VEVOR | Model: SS-003

1. Hua Neke Atuview

The VEVOR Under Sink RO System (Model SS-003) is a tankless reverse osmosis water filtration system designed to provide purified water directly from your faucet. This system features an 8-stage filtration process, a 600 GPD (Gallons Per Day) powerful flow rate, and a smart display faucet for real-time TDS monitoring.

VEVOR Under Sink RO System with 600 GPD flow rate and key features

Image: VEVOR Under Sink RO System highlighting 600 GPD flow rate, 10-layer RO membrane, >99.99% filtration efficiency, 2:1 pure to drain ratio, 75% space saving, 0.0001μm RO, TDS monitor, BPA free, and low sodium.

2. Nga korero haumaru

  • Pānuihia nga tohutohu katoa i mua i te whakauru me te whakamahi.
  • Ensure proper electrical grounding for the power supply.
  • Turn off the main water supply before performing any installation or maintenance.
  • Kaua e whakamahi me te wai kaore i te haumaru microbiologically, kaore ranei e mohiotia te kounga me te kore e tika te whakakore i te mate i mua i muri mai ranei i te punaha.
  • Keep the system away from direct sunlight and heat sources.
  • If the device is not used for more than one week, disconnect the power, turn off the water supply, and turn on the faucet to drain the system. Rinse for 10 minutes before using again.

3. Aratohu Whakauru

3.1 Rarangi Arowhai I mua i te Whakaaturanga

  • Tirohia kei te noho nga waahanga katoa me te kore e pakaru.
  • Ensure you have the necessary tools (drill, wrench, screwdriver, etc.).
  • Whakapumautia te ū ki nga waehere paipa o te rohe.

3.2 Whakaritenga Whakauru

Diagram showing VEVOR RO system installation under a sink with dimensions and requirements

Image: Installation diagram illustrating product dimensions, reserved dimensions, faucet hole diameter, water inlet/outlet connections, and power supply requirements.

Nga Whakaritenga Whakauru
WhakaritengaNga korero
Hunga Hua15.63" x 5.39" x 13.66" (397x137x347mm)
Reserved Dimensions15.75" x 5.91" x 15.75" (400x150x400mm)
Tuku HikoTwo-prong power socket
Faucet Hole Diameter1 1/4" mount, 1/4" pilot
Kouru WaiCan be shared with the sink
Putanga WaiCan be shared with the sink
Te Matotoru o te Papa Kaunta mōrahi2.16in / 55mm

3.3 Taahiraa-i-Taahiraa

  1. Whakapaia te Rohe Tāuta: Clear the under-sink cabinet. Ensure sufficient space for the unit and access for maintenance.
  2. Tāutahia te Kōrere: Drill a 1 1/4" hole in the countertop (if not already present) for the dedicated RO faucet. Secure the faucet according to the provided hardware.
  3. Hononga Wai Putanga: Turn off the cold water supply. Install the provided adapter to the cold water line under the sink. Connect the input tube from the RO system to this adapter.
  4. Connect Drain Saddle: Install the drain saddle onto the drain pipe under the sink. Drill a small hole in the drain pipe through the saddle. Connect the waste water tube from the RO system to the drain saddle.
  5. Connect Filtered Water Outlet: Connect the filtered water tube from the RO system to the dedicated RO faucet.
  6. Tāuta Tātari: Insert the filter cartridges into their respective slots (PCF and RO) on the main unit. Twist to lock them into place.
  7. Hononga Hiko: Plug the power adapter into a two-prong power socket.
  8. Horoia te Pūnaha: Turn on the cold water supply. Open the RO faucet and let the water run for at least 30 minutes to flush the system and remove any air bubbles or carbon fines.

For visual guidance, you can refer to the official VEVOR YouTube installation playlist: VEVOR RO System Installation Playlist

4. Nga Tohutohu Whakahaere

4.1 Whakaohoatanga Tuatahi

  • I muri i te whakaurunga, whakarite kia noho haumaru nga hononga katoa, kia kore e pakaru.
  • Turn on the main water supply and plug in the system.
  • Open the dedicated RO faucet and allow water to flow for approximately 30 minutes to flush the system. This removes air and any initial carbon dust from the filters.

4.2 Whakamahinga ia ra

  • To dispense purified water, simply open the dedicated RO faucet.
  • The smart display on the faucet will show the TDS (Total Dissolved Solids) level of the purified water.
  • The system operates automatically, filtering water as needed.

4.3 Filter Status Indicators

VEVOR Under Sink RO System main unit with filter indicators

Whakaahua: Mua view of the VEVOR RO system showing filter status indicators (1 and 2) and a 'Work' indicator.

The main unit features LED indicators for Filter 1 (PCF) and Filter 2 (RO), along with a 'Work' indicator. These lights provide status updates on filter engagement and system operation.

5. Tiaki

5.1 Tātari Whakakapinga

Regular filter replacement is crucial for maintaining water quality and system performance. The system is designed for easy, tool-free filter changes.

  • PCF Filter (Filter 1): Typically replaced every 12 months.
  • RO Filter (Filter 2): Typically replaced every 24 months.
VEVOR PCF Composite Water Filter Replacement

Image: VEVOR PCF Composite Water Filter Replacement cartridge.

VEVOR RO Water Filter Replacement

Image: VEVOR RO Water Filter Replacement cartridge.

Procedure for Filter Replacement:

  1. Whakawetohia te puna wai ki te pūnaha RO.
  2. Wewetehia te urutau hiko.
  3. Rotate the filter cartridge to the unlock position (indicated by an open padlock symbol).
  4. Pull the old filter cartridge out.
  5. Insert the new filter cartridge, aligning it correctly.
  6. Rotate the new filter cartridge to the lock position (indicated by a closed padlock symbol).
  7. Plug in the power adapter and turn on the water supply.
  8. Flush the system by running water from the RO faucet for several minutes to remove air and any new filter residue.

5.2 Te Horoi Pūnaha

Periodically wipe down the exterior of the unit with a clean, damp kakahu. Kaua e whakamahi i nga matū kino me nga horoi horoi.

6. Te Raru

This section provides solutions to common issues. For more complex problems, please contact VEVOR customer support.

  • Kore Rere Wai: Check if the water supply is turned on, the system is plugged in, and filters are correctly installed and not clogged.
  • Rere Wai Puturi: This may indicate clogged filters. Replace the PCF or RO filter as needed. Ensure adequate water pressure.
  • Te reka/kakara rerekē: Flush the system thoroughly. If the problem persists, replace the filters.
  • High TDS Reading: If the smart faucet displays a high TDS reading, the RO membrane may need replacement.
  • turuturu: Turn off the water supply immediately. Check all connections and ensure they are tightened properly. Inspect O-rings and replace if damaged.

7. Whakatakotoranga

Whakatakotoranga Hua
ĀhuahiraTaipitopito
WaitohuVEVOR
TauiraSS-003
Te Mahinga Whakaputa ia ra600 GPD
Tātari Stages8-Stage (PCF, RO)
RO Membrane Filtration0.0001 μm
Tikanga Whiriwhiringa>99.99%
Ōwehenga Parakore ki te Tātari2:1
Te Rere Wai34 oz/min
Whakatauranga ManaDC24V / 4A (Via AC100-240V 50/60Hz adapter)
Te Pawera Wai40-100°F (5-38°C)
TiwhiketeSGS Tested (Meets ANSI/42&53 Standards), FCC Compliant

For detailed SGS test reports, scan the QR code on the product packaging or visit: SGS Report

8. Pūtāhui me te Tautoko

VEVOR is committed to delivering reliable and affordable products. Warranty information and technical support are available through official channels.

  • Warranty ends automatically if using replacement parts, filters, membranes, or other accessories that are not sold or manufactured by VEVOR.
  • Ka pakaru te miihini, me tapahi wawe te wai me te hiko.

For technical support and e-warranty certificates, please visit the VEVOR support page: www.vevor.com/support

9. Ataata Hua Whaimana

No official product videos from the seller were found in the provided data. Please refer to the VEVOR support website or YouTube channel for any available video guides.

© 2024 VEVOR. Katoa nga mana.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.