This manual provides essential information for the safe and effective use of the Enersys Cyclon 0800-0004 X-Cell 2 Volt/5 Amp Hour Sealed Lead Acid Battery. This pure lead sealed lead acid battery is designed for general applications such as emergency lighting, UPS systems, and electronic equipment.

Key features of the Cyclon battery include:

  • Kiato Hiko: Offers high-rate power density per unit weight, allowing for more energy-supporting features.
  • Porohita Ora: Provides 50% to 200% greater full cycle capability compared to competitive lead products, delivering up to 300 cycles (100% DOD, C/5).
  • Float Life: Designed for a ten-year life at 25°C, C/5, to 80% of rated capacity.
  • High Stable Voltage Delivery: Achieved through low internal resistance, providing a flat discharge voltage profile similar to Nickel Cadmium.
  • Haumaru: Emits minimal to no gassing under normal charging conditions, making it safe for installation in various environments.
Enersys Cyclon 0800-0004 X-Cell Battery

Whakaahua 1: Mua view of the Enersys Cyclon 0800-0004 X-Cell battery, showing the brand name, model, and key specifications.

Diagram of Cyclon Single Cell internal design

Figure 2: Diagram illustrating the internal components of a Cyclon Single Cell, including the resealable safety valve, pure lead plates, AGM plate separator, and steel can enclosure.

Tatūnga me te Tāuta

Proper setup is crucial for the optimal performance and longevity of your Enersys Cyclon battery. Follow these guidelines carefully:

1. Tirotiro Tuatahi

Upon receiving the battery, inspect it for any signs of physical damage. Ensure the terminals are clean and free from corrosion. Do not use the battery if it appears damaged.

2. Nga Tikanga Taiao

Install the battery in a clean, dry, and well-ventilated area. Avoid locations with extreme temperatures, direct sunlight, or high humidity. The recommended operating temperature range is typically between -65°C to +80°C, but optimal performance and float life are achieved around 25°C.

3. Nga Aratohu Hononga

Connect the battery to your equipment using appropriate cables and connectors. Ensure correct polarity: connect the positive (+) terminal of the battery to the positive terminal of your device, and the negative (-) terminal to the negative terminal. Incorrect polarity can damage the battery and connected equipment.

Runga view of Enersys Cyclon battery terminals

Whakaahua 3: Runga view of the Enersys Cyclon battery, showing the positive and negative terminals for connection.

4. Whakataki Tuatahi

While Cyclon batteries are shipped with a charge, it is recommended to fully charge the battery before its first use, especially if it has been stored for an extended period. Use a charger specifically designed for sealed lead-acid batteries with a 2-volt output. Refer to the charger's instructions for proper charging procedures.

Nga Tohutohu Whakahaere

The Enersys Cyclon battery is designed for reliable performance in various applications. Observe the following during operation:

1. Discharge Characteristics

The Cyclon battery provides a high stable voltage delivery due to its low internal resistance. This results in a flat discharge voltage profile, ensuring consistent power output throughout its discharge cycle. Avoid deep discharges below the recommended voltage levels to maximize battery life.

2. Charging During Operation

For applications requiring continuous power, the battery can be kept on a float charge. Ensure the charging voltage is within the manufacturer's specified range for 2-volt sealed lead-acid batteries to prevent overcharging or undercharging.

3. Whakatupato Haumaru

Although Cyclon batteries are sealed and non-spillable, always handle them with care. Do not short-circuit the terminals. Avoid exposing the battery to open flames or excessive heat. Ensure proper ventilation if the battery is enclosed, even though gassing is minimal under normal conditions.

Te tiaki

Enersys Cyclon batteries are maintenance-free due to their sealed, non-spillable design. However, periodic checks can help ensure optimal performance and longevity:

1. Terminal Inspection

Periodically check the battery terminals for cleanliness and tight connections. Clean any dust or dirt with a dry cloth. Do not use abrasive cleaners or solvents.

2. Rokiroki

If the battery is to be stored for an extended period, ensure it is fully charged before storage. Store in a cool, dry place away from direct sunlight and extreme temperatures. Recharge the battery every 6-9 months during storage to prevent self-discharge and maintain capacity.

3. Whakakahoretanga Patahiko

Do not dispose of the battery in household waste. Sealed lead-acid batteries contain recyclable materials and should be recycled according to local regulations. Contact your local recycling center for proper disposal instructions.

Raparongoā

This section addresses common issues you might encounter with your Enersys Cyclon battery.

RaruraruTake peaRongoā
Kaore te pākahiko e mau ki te utuUndercharging; End of life; Internal damageEnsure charger is compatible and functioning correctly. Fully charge the battery. If issue persists, battery may need replacement.
Vol ititage whakaputangaBattery discharged; Loose connections; OverloadRecharge the battery. Check and tighten all connections. Ensure the load does not exceed battery capacity.
Karekau te pākahiko e utu anaFaulty charger; Incorrect connection; Battery faultVerify charger functionality with another battery or device. Check polarity and connections. If battery is severely discharged, it may not accept charge.

If you experience issues not listed here or if the suggested solutions do not resolve the problem, please contact Enersys customer support.

Whakatakotoranga

Detailed specifications for the Enersys Cyclon 0800-0004 X-Cell Battery:

  • Tau tauira: 0800-0004
  • Momo Pūhiko: Waikawa Mata Hiri (SLA)
  • Voltage: 2 Volts
  • Raukaha: 5 Amp Hāora (Ah)
  • Rahi Hua: 1.75 x 1.75 x 3.21 inihi
  • Taumaha Tūemi: 12.8 hekere
  • Kaihanga: Enersys
  • Te Ra Tuatahi Wātea: Pipiri 18, 2004
  • Whakamahinga Manakohia: Emergency lighting, UPS systems, electronic equipment

Te Haumaru me nga Whakatupato

Please read and understand all safety warnings before handling or using the battery.

Proposition 65 Warning label on Enersys Cyclon battery

Figure 4: Warning label on the Enersys Cyclon battery, including Proposition 65 warning and other safety symbols.

Kaupapa 65 Whakatupato

WHAKATŪPATO: Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and reproductive harm. Batteries also contain other chemicals known to the State of California to cause cancer. Wash hands after handling.

Whakatupato Haumaru Whānui

  • Risk of fire, explosions or burns. Do not disassemble, heat above 80°C or incinerate.
  • Follow product charging instructions.
  • Do not charge in sealed container.
  • Always wear appropriate personal protective equipment (PPE) such as safety glasses and gloves when handling batteries.
  • Puritia nga pākahiko kei taea e nga tamariki.
  • In case of accidental contact with battery contents, flush with water immediately and seek medical attention.

Pūtāhui me te Tautoko

For warranty information, please refer to the documentation provided with your purchase or contact Enersys directly. The manufacturer's warranty typically covers defects in materials and workmanship under normal use.

Nga korero Whakapā a te Kaihanga:

Enersys Energy Products Inc.
Warrensburg, MO 64093-9301
Waea: (610) 208-1991
Webpae: www.enersys.com

For full list of the warning and precautionary statements and applicable SDS sheet, please visit the Enersys webpae.

Tuhinga e pa ana - 0800-0004

Preview Ngā Whakatakotoranga Hangarau mō te Pūhiko Hōia a EnerSys ArmaSafe Plus 12FV120
He pepa raraunga hangarau mō te pākahiko taumata-hoia a EnerSys ArmaSafe Plus 12FV120, e whakaatu ana i te kaha 126 Ah, 1225A CCA, me te whānuitanga pāmahana whakahaere. Kei roto ko ngā whakatakotoranga, ngā āhuatanga, ngā painga, me ngā mōhiohio tutuki i ngā whakaritenga.
Preview HAWKER Perfect Plus Baterie: Uživatelská Příručka pro Trakční Baterie PzS/PzB
Whakanuia te taapiri me te pākahiko hiko HAWKER Perfect Plus™ pato PzS/PzB. Obsahuje informace o bezpečnosti, provozu, nabíjení, údržbě, skladování a volitelném příslušenství pro průmyslová vozidla.
Preview Pukapuka Ā-ringa mō ngā Pūhiko Waikawa-Mata kua Waipukehia ki te Rino
He pukapuka ārahi whānui mō ngā pākahiko EnerSys Ironclad Flooded Lead-Acid, e kapi ana i te whakamahinga haumaru, te tāutanga, te whakahaere, te tiaki, me te whakatau raruraru.
Preview Pukapuka Kaiwhakamahi mō ngā Pūhiko Tiwhikete EnerSys Perfect Plus me te Kore-Wai ATEX UKEX
This user manual provides comprehensive information on the safe handling, operation, maintenance, and installation of EnerSys Perfect Plus and Water Less ATEX UKEX certified batteries. It covers technical specifications, safety precautions, charging, discharging, and optional accessories like the Aquamatic water filling system and electrolyte circulation system.
Preview Pukapuka Tāutanga, Whakahaere me te Tiaki PowerSafe® SBS® EON®
He aratohu whānui mō te tāutanga, te whakahaere, me te tiaki i ngā pākahiko EnerSys PowerSafe SBS EON, e whakaatu ana i te hangarau TPPL mō te mahi pai ake me te roa o te ora.
Preview Hawker Lifetech® Pūhiko Whakakapi - Ngā Tohutohu mō te Whakamahi
He tohutohu whānui mō te whakamahi i ngā rihi pākahiko Hawker Lifetech® Modular, e kapi ana i te haumaru, te whakamahinga kua tūtohutia, ngā hononga hiko, te whakahaere, me ngā waehere hapa. I hangaia mō ngā pākahiko waikawa-mata ahumahi, AGM, me te Gel.