Star 127189A

Star 1/2 HP Submersible Well Pump Control Box

Model 127189A Instruction Manual

1. Kupu Whakataki

This manual provides detailed instructions for the installation, operation, and maintenance of your Star 1/2 HP Submersible Well Pump Control Box, Model 127189A. Please read this manual thoroughly before installation and use to ensure safe and efficient operation. This control box is designed for use with 1/2 HP submersible well pumps operating at 230 Volts and is suitable for both outdoor and indoor installations.

2. Nga korero haumaru

WARNING: DISCONNECT POWER BEFORE OPENING. DANGER OF ELECTRIC SHOCK.

Always observe the following safety precautions to reduce the risk of electric shock, injury, or fire:

  • Installation and servicing must be performed by a qualified electrician or authorized service personnel in accordance with all local and national electrical codes.
  • Ensure the main power supply to the pump system is disconnected and locked out before attempting any installation, maintenance, or troubleshooting.
  • Manatokohia ko te voltage and horsepower ratings of the control box match those of your submersible well pump.
  • Do not operate the control box if it is damaged or has exposed wiring.
  • This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm (Proposition 65 warning). Wash hands after handling.

3. Nga Hua o te Hua

The Star 1/2 HP Submersible Well Pump Control Box, Model 127189A, offers the following key features:

  • Designed for 1/2 HP submersible well pumps.
  • Operates on 230 Volt electrical systems.
  • Suitable for both outdoor and indoor installations.
  • Features a heavy-duty terminal block for secure electrical connections.
  • Equipped with side and bottom knockouts for convenient wire installation.
  • Interchangeable with many industry-standard control boxes.
  • Incorporates a universal voltage relay for reliable performance.
Star 1/2 HP Submersible Well Pump Control Box, Model 127189A

Whakaahua 1: Mua view of the Star 1/2 HP Submersible Well Pump Control Box, Model 127189A, showing the warning label and model information.

4. Tatūnga me te Tāuta

Proper installation is critical for the safe and efficient operation of your well pump system. It is highly recommended that installation be performed by a qualified professional.

  1. Momotu Hiko: Before beginning any work, ensure that all power to the well pump circuit is completely disconnected at the main breaker panel. Verify with a voltage Kaiwhakamatautau.
  2. Whakapiki: Mount the control box securely to a wall or suitable surface using appropriate fasteners. Ensure the mounting location is protected from direct weather exposure if installed outdoors, or in a dry, accessible location if indoors.
  3. Whakarite Waea: Use the side or bottom knockouts to route the electrical conduits and wires into the control box. Ensure all wiring complies with local electrical codes.
  4. Hononga Waea: Connect the pump motor wires, power supply wires, and ground wire to the heavy-duty terminal block inside the control box. Refer to the wiring diagram provided with your specific well pump for correct terminal assignments. Ensure all connections are tight and secure.
  5. Te Katinga o te Āpiti: Once all connections are made and verified, securely close the control box cover.
  6. Whakaora Hiko: Restore power to the circuit and test the pump operation.

5. Nga Tohutohu Whakahaere

The Star 1/2 HP Submersible Well Pump Control Box is designed for automatic operation in conjunction with your well pump and pressure switch (or other control device). Once properly installed and powered, the control box will manage the electrical supply to the pump based on the signals received from the system's pressure switch or other controlling mechanisms.

  • Ensure the control box cover is always securely closed during operation.
  • Monitor the pump system for normal operation. Unusual noises or lack of water flow may indicate a problem.

6. Tiaki

Regular maintenance helps ensure the longevity and reliable performance of your control box and well pump system.

  • Tirohanga Tau: At least once a year, with the power disconnected, inspect the control box for any signs of corrosion, loose connections, or damaged wiring.
  • Te ma: Keep the exterior of the control box clean and free from dust, dirt, and debris.
  • Whakahau: Ensure that any ventilation openings (if present) are not obstructed to prevent overheating.
  • Taki Ngaio: Consider having a qualified technician perform a comprehensive check of your well pump system, including the control box, every few years.

7. Te Raru

If your well pump system is not functioning correctly, consider the following troubleshooting steps. Always disconnect power before inspecting the control box.

  • Puma Kaore i te timata:
    • Check the main circuit breaker for the pump system.
    • Verify that the pressure switch is functioning correctly and calling for water.
    • Inspect wiring connections inside the control box for looseness or corrosion (with power off).
  • Te Pahikara Auau:
    • This may indicate a problem with the pressure tank, a leak in the system, or a faulty pressure switch, rather than the control box itself.
  • No Power to Control Box:
    • Tirohia te hiko matua me te ara iahiko.

If these steps do not resolve the issue, contact a qualified pump technician for further diagnosis and repair.

8. Whakatakotoranga

Tau tauira127189A
Horsepower0.50 HP
Voltage230 Volts
Wattage1380 Watts
Taumaha Tūemi2.84 pauna
Hunga Hua6 x 5 x 10 inihi
KāhuaRuku
KaihangaStandard Plumbing Supply

9. Pūtāhui me te Tautoko

For warranty information and technical support, please refer to the documentation provided at the time of purchase or contact Star Water Systems directly. You can also visit the Star Store on Amazon mo etahi atu korero hua me nga rauemi.

Tuhinga e pa ana - 127189A

Preview STAR Capella 2HCX Lifted Parts Manual - Comprehensive Component Guide
Detailed parts manual for the STAR Capella 2HCX Lifted utility vehicle. Find part numbers, descriptions, and specifications for all components, organized by system.
Preview Star Two Sided Grills GX10, GX14, GX20 Series: Installation and Operation Manual
Comprehensive installation, operation, maintenance, and safety instructions for Star Two Sided Grills models GX10, GX14, and GX20 series. Includes electrical specifications, troubleshooting, and warranty information.
Preview اطلاعات و بیانیه موافقت برای فرایند جهت‌دهی شغلی KAoA-STAR
راهنمای جامع برنامه KAoA-STAR برای جهت‌دهی شغلی دانش‌آموزان با نیازهای ویژه در نوردراین-وستفالن، شامل شرح عوامل استاندارد، نحوه اشتراک‌گذاری اطلاعات و فرم رضایت‌نامه والدین.
Preview STAR Paragon Inflatable Kayak Kopa Tohutohu
Arata'i taahiraa-i-te-raa me pehea te tika o te kopa me te penapena i to waka waka inflatable STAR Paragon kia ngawari te kawe me te rokiroki.
Preview Manetageanleitung mo Star Waschbeckenunterschrank X9T Q5 705
Detaillierte Manetageanleitung für den Star Waschbeckenunterschrank, Modell X9T Q5 705. Enthält Schritt-für-Schritt-Anweisungen, Teileliste und wichtige Sicherheitshinweise für eine erfolgreiche Installation.
Preview Aratohu Tatūnga Māmā mō te Star mC-Print3: Te Hononga ki ngā Pūrere
This guide provides step-by-step instructions for setting up the Star mC-Print3 printer. It covers checking supplied accessories, downloading the mC-Print3 utility, and connecting the printer to iOS, Android, Mac, Linux, and Windows devices via Bluetooth, USB, or Wired LAN. Includes troubleshooting tips and rear cover installation.