StarTech.com 8 Outlet Horizontal 1U Rack Mount PDU Power Strip (RKPW081915) Instruction Manual

Model: RKPW081915

1. Kupu Whakataki

This manual provides instructions for the installation, operation, and maintenance of your StarTech.com 8 Outlet Horizontal 1U Rack Mount PDU Power Strip (Model RKPW081915). This Power Distribution Unit (PDU) is designed to provide reliable power distribution and surge protection for equipment within network server racks and cabinets.

2. Nga korero haumaru

WHAKATŪPATO: Ki te kore e whai i ēnei tohutohu haumaru, ka pāngia pea koe e te ahi, te ru hiko, ētahi atu whara, kino rānei.

3. Ihirangi mokete

StarTech.com RKPW081915 PDU and Instruction Manual in packaging

Image: The StarTech.com PDU and its instruction manual, as typically found in the product packaging.

  • 1x 8 Outlet Horizontal 1U Rack Mount PDU Power Strip (RKPW081915)
  • 1x Manual Tohutohu

4. Hua Neke Atuview

The StarTech.com RKPW081915 is a 1U horizontal rack-mountable PDU designed for efficient power distribution in server environments. It features 8 NEMA 5-15R outlets, a 6-foot power cord, and built-in surge protection.

Nga waahanga o mua

Mua me muri view of the StarTech.com RKPW081915 PDU with labeled components

Whakaahua: Taipitopito view of the PDU's front and back, highlighting the LED indicators, power switch, and outlets.

  • LED Surge Indicator: Illuminates when surge protection is active.
  • LED Ground Indicator: Illuminates when the PDU is properly grounded.
  • Power/Reset Switch: Controls power to all outlets and acts as a circuit breaker reset.

Ngā Āhuatanga Paewhiri Whakamuri

Whakamuri view of the StarTech.com RKPW081915 PDU showing the 8 NEMA 5-15R outlets and power cord

Image: Close-up of the rear of the PDU, displaying the eight power outlets and the attached power cord.

5. Tatūnga

5.1 Te Wetewete

Carefully remove the PDU and all components from the packaging. Inspect for any damage during shipping. If any damage is found, contact your vendor immediately.

5.2 Whakapiki Rack

The RKPW081915 PDU is designed for horizontal mounting in any standard 19-inch server rack that is 4 inches (10.16 cm) deep or greater. It occupies 1U of rack space.

  1. Align the mounting ears of the PDU with the desired rack unit (U) on your server rack.
  2. Secure the PDU to the rack using appropriate rack screws (not included). Ensure both sides are firmly attached.
StarTech.com RKPW081915 PDU installed horizontally in a server rack

Image: The PDU mounted horizontally within a server rack, demonstrating its 1U form factor and integration with other equipment.

StarTech.com RKPW081915 PDU with dimensions and rack compatibility information

Image: A visual representation of the PDU's height (1U) and cable length (6ft), confirming its compatibility with standard 19-inch racks.

5.3 Hononga Pūrere

  1. Ensure the PDU's power/reset switch is in the OFF position.
  2. Plug the power cords of your network and server equipment into the 8 NEMA 5-15R outlets on the rear of the PDU.
  3. Connect the integrated 6-foot power cord of the PDU to a grounded 120V/15A power source.

Video: Demonstrates the installation of a rack-mounted power strip, showing how it integrates into a server rack and connects to devices.

Video: An official product video from StarTech.com showcasing the 8 Outlet Horizontal 1U Rack Mount PDU Power Strip for network server racks, highlighting its surge protection features.

Video: A demonstration of the StarTech 8 Outlet Horizontal 1U Rack Mount PDU, showing its physical attributes and how it fits into a rack setup.

Ataata: Kua mutuview of an 8 Outlet Rack-Mount PDU, detailing its features and benefits for organizing power in a rack system.

Video: A demonstration of a PDU Outlet Horizontal, highlighting its design and functionality for power distribution.

6. Nga Tohutohu Whakahaere

6.1 Kei te Hiko / Weto

To power on the connected equipment, press the Power/Reset switch on the front panel to the ON position. To power off, press the switch to the OFF position.

6.2 Tohu LED

6.3 Kaiwhati iahiko

The Power/Reset switch also functions as a circuit breaker. If an overload occurs, the switch will trip to the OFF position, cutting power to all connected devices to prevent damage. To reset the circuit breaker, reduce the load on the PDU and then press the switch back to the ON position.

7. Tiaki

7.1 Te horoi

To clean the PDU, ensure it is powered off and disconnected from the main power source. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.

7.2 Tirotiro auau

8. Te Raru

RaruraruTake peaRongoā
Kaore he mana ki nga taputapu hono.PDU is off or circuit breaker tripped.Ensure the Power/Reset switch is ON. If it tripped, reduce the load and reset the switch.
Ground LED is off.Te taunga hē.Ensure the PDU is plugged into a properly grounded outlet. Check the building's electrical wiring.
Surge LED is off.Kua ngoikore te parenga ngaru.The PDU's surge protection may no longer be active. Replace the unit to ensure continued protection.
Devices are not receiving enough power.PDU is overloaded.Reduce the total power draw of connected devices to stay within the 15A limit.

9. Whakatakotoranga

ĀhuahiraTaipitopito
Tau tauiraRKPW081915
WaitohuStarTech.com
Nga Putanga Hiko Katoa8 x NEMA 5-15R
Whakauru Voltage120 Volts AC
Whakatauranga o naianei15 Amps
Te Roa Waea Hiko6 putu (1.8 mita)
Rack Unit (RU)1U
WhakaekeHorizontal 19-inch Rack Mount
Ahu (LxWxH)19 x 3.76 x 1.68 inihi (48.26 x 9.55 x 4.27 cm)
Taumaha Tūemi4.85 pauna (2.2 kg)
Nga waahanga motuhakeMountable, On/Off Switch, Surge Protection, Built-in Circuit Breaker
Casing RauemiRugged Steel

10. Pūtāhui me te Tautoko

This StarTech.com product is backed by a lifetime warranty, ensuring long-term reliability and peace of mind. In addition, free lifetime 24/5 multi-lingual technical assistance is available to help you with any questions or issues you may encounter.

For technical support or warranty claims, please visit the official StarTech.com webpaetukutuku, whakapā atu ranei ki ta raatau ratonga kaihoko. Puritia to riirii hoko mo te whakamanatanga whakamana.

Tuhinga e pa ana - RKPW081915

Preview StarTech.com 14-Putanga 1U Rackmount PDU me te Parenga Ngaru - Aratohu Tīmatanga Tere
He aratohu tīmatanga tere mō te StarTech.com 1415B8H-RACK-PDU-SP, he PDU whakairinga whatanga 1U me te tiakitanga ngaru me ngā putanga 14, tae atu ki ngā tohutohu tāutanga mō te whakairinga whatanga me te poutū.
Preview StarTech.com 1U Rackmount PDU me ngā Putanga 13 - Taura 2.4m | 1315B8H-RACK-PDU
He aratohu tīmatanga tere mō te StarTech.com 1U Rackmount PDU (1315B8H-RACK-PDU) e whakaatu ana i ngā putanga NEMA 5-15R e 13, he taura hiko 2.4m, me ngā āheinga whakairi whatanga 19-inihi. Kei roto ko ngā tohutohu tāutanga me ngā whakatūpato haumaru.
Preview StarTech.com Adjustable 4 Post Open Frame Server Rack User Manual
This user manual provides assembly instructions, safety warnings, package contents, requirements, installation steps, operation details, and warranty information for the StarTech.com Adjustable 4 Post Open Frame Server Rack (SKU: 4POSTRACKxU).
Preview StarTech.com Whariki Whakamau Pakitara Whakarite - Aratohu Tīmatanga Tere mō te Kete Papatahi
He aratohu tīmatanga tere mō te StarTech.com Adjustable Wall Mount Bracket - Flat-Pack, e whakaatu ana i ngā āhuatanga, ngā whakaritenga, ngā ihirangi o te kete, te huihuinga, me ngā tohutohu whakairi pakitara mō ngā taputapu tūmau me te whatunga.
Preview StarTech.com 1HE Rackmontage PDU mit 14 Ausgängen und Überspannungsschutz – Schnellstartanleitung
Schnellstartanleitung für die StarTech.com 1HE Rackmount PDU (Modell 1415B8H-RACK-PDU-SP) mit 14 NEMA 5-15R-Ausgängen, Überspannungsschutz und einem 2,4 m langen Stromkabel. Whakanuia nga whakaurunga mo te Rackmontage und poutū Manetage.
Preview StarTech.com Adjustable Depth Open Frame Wall Mount Rack Quick Start Guide
Quick start guide for StarTech.com adjustable depth open frame wall mount racks, including product IDs, installation steps, package contents, and specifications.