Wilo 4105032

Pukapuka Tohutohu mō te Papu Hurihuri Waihiko Rotor Makuku Tere Toru a Wilo 4105032 Star S 21F

1. Kupu Whakataki

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Wilo 4105032 Star S 21F Three Speed Wet Rotor Hydronic Circulating Pump. This pump is designed for use in hot-water heating systems, industrial circulation systems, cold-water systems, and air-conditioning systems. It is not approved for use with domestic hot water. The pump features a bronze volute and a wet rotor design.

2. Nga korero haumaru

Please read and understand all safety instructions before installing or operating the pump. Failure to follow these instructions may result in personal injury, property damage, or electric shock.

  • Haumaru Hiko: Ensure the power supply is disconnected before any installation or maintenance work. All electrical connections must be performed by a qualified electrician in accordance with local and national electrical codes. The pump operates on 115-Volt, 60Hz power.
  • Haumaru Pēhanga: The maximum working pressure for this pump is 145 PSI. Do not exceed this pressure.
  • Haumaru Pamahana: The pump is designed for a temperature range of 14°F to 230°F. Ensure system temperatures remain within this range.
  • Tāutatanga: The pump can be installed in any position where the shaft is horizontal. Improper installation can lead to malfunction or damage.
  • Whānui: Do not operate the pump dry. Ensure the system is filled with fluid before starting.

3. Hua Neke Atuview

The Wilo Star S 21F is a three-speed circulating pump designed for hydronic systems. It features a robust construction and a user-selectable speed setting to optimize performance and energy consumption.

Wilo Star S 21F Three Speed Wet Rotor Hydronic Circulating Pump
An image showing the Wilo Star S 21F circulating pump. The pump is green with a black electrical connection box and a red speed selector switch. The label on the pump body displays model information and technical specifications.

Wae matua:

  • Whare Pump: Green-colored body, typically bronze volute.
  • Motini: Wet rotor design, 115-Volt, 60Hz.
  • Whakawhiti Kaitohu Tere: Red rotary switch on the electrical box for selecting one of three speeds.
  • Pouaka Hononga Hiko: Black enclosure for wiring connections.
  • Flange Connections: Standard connections for system integration.

4. Tatūnga me te Tāuta

He mea nui te tāutanga tika mō te mahi me te roa o te wā e whakamahia ana te papu.

  1. Whakaritenga Pūnaha: Ensure the heating or cooling system is drained and clean before installation.
  2. Tūnga Whakapuru: The pump can be installed in any position, provided the motor shaft remains horizontal. This is critical for proper lubrication and cooling of the wet rotor.
  3. Hononga Paipa: The pump uses 3/4-inch to 1-1/2-inch standard flanges. Use appropriate gaskets (typically supplied with the pump) and ensure a watertight seal. Avoid overtightening the flange bolts.
  4. Waea hiko:
    • Disconnect power at the main breaker before beginning any wiring.
    • Open the electrical connection box.
    • The pump features quick and easy wire connectors. To insert wires, displace the white tabs 90 degrees to open the holes. Insert the stripped wires and then return the tabs to their original position to secure the connection.
    • Connect the pump to a dedicated 115-Volt, 60Hz circuit. Ensure proper grounding.
    • Close the electrical connection box securely.
  5. Whakakī Pūnaha: After installation, slowly fill the system with fluid, ensuring all air is purged from the pump and piping. Air in the system can cause noise and damage to the pump.

5. Nga Tohutohu Whakahaere

The Wilo Star S 21F pump offers three selectable speeds to match system requirements.

  1. Whakahiko: Once the pump is installed and the system is filled, restore power to the circuit.
  2. Tīpakonga Tere: Locate the red rotary switch on the electrical connection box. This switch allows you to select one of three operating speeds:
    • Tere 1 (Taiao): Lowest power consumption (55W), suitable for minimal flow requirements.
    • Tere 2: Medium power consumption (77W), for moderate flow.
    • Speed 3 (Max): Highest power consumption (98W), for maximum flow and head.
    Rotate the switch to the desired speed setting. The pump will begin operation at the selected speed.
  3. Aroturuki: Observe the system for proper circulation and listen for any unusual noises.

6. Tiaki

The Wilo Star S 21F is designed for minimal maintenance. However, periodic checks can ensure optimal performance and extend its lifespan.

  • Tirohanga Tau: Annually inspect the pump for any signs of leaks, corrosion, or unusual wear.
  • Te Kounga o te Wai Pūnaha: Ensure the system fluid is clean and free of debris. Contaminants can reduce pump efficiency and lifespan.
  • Hononga Hiko: Periodically check electrical connections for tightness and signs of overheating. Disconnect power before checking.
  • Puring hau: If the pump becomes noisy, it may indicate air in the system. Follow system-specific procedures to purge air.

7. Te Raru

Tirohia te ripanga i raro nei mo nga take noa me o raatau otinga ka taea.

RaruraruTake peaRongoā
Kaore e timata te papuNo power; faulty wiring; seized impellerCheck power supply and circuit breaker. Verify electrical connections. Consult a qualified technician if impeller is seized.
He haruru te papuAir in system; cavitation; foreign object in pumpPurge air from the system. Check system pressure. Inspect pump for obstructions (disconnect power first).
He iti te rereIncorrect speed setting; air in system; clogged filter; undersized pumpIncrease speed setting. Purge air. Check and clean system filters. Verify pump sizing for application.
E turuturu ana te papuLoose connections; damaged gaskets; cracked housingTighten flange connections. Replace damaged gaskets. If housing is cracked, pump replacement may be necessary.

8. Whakatakotoranga

WhakatakotorangaUara
WaitohuWiro
Tau tauira4105032 (Typ Star S 21 FX)
Voltage115 Volts
Auautanga60 Hz
Maximum Current (I max)0.70 A
Whakamahi Hiko (W)Speed 3: 98W, Speed 2: 77W, Speed 1: 55W
Rere Rere Morahi21 Karini mo ia Meneti
Teitei Whakaara Mōrahi (Upoko)21 Puawai
Awhe Pawera14°F ki te 230°F (-10°C ki te 110°C)
Te Morahi Mahi Mahi145 PSI
RauemiStainless Steel (shaft), Bronze (volute)
Taumaha Tūemi7.08 pauna (3.22 kg)
Rahi Flange3/4-Inch - 1-1/2-Inch standard flange
Karaehe WhakapiriCSA enclosure 2
Karaehe WehengaTe akomanga F

9. Pūtāhui me te Tautoko

Wilo provides a 3-year limited warranty from the date of purchase for Residential Business Services products. For warranty claims, technical support, or further assistance, please contact Wilo customer service or your authorized dealer.

Tuhinga e pa ana - 4105032

Preview Wilo-Star RS, RSD, ST, RSG, AC Circulating Pump Tāuta me ngā Tohutohu Whakahaere
Te whakaurunga me nga tohutohu whakahaere mo Wilo-Star RS, RSD, ST, RSG, AC circulating pumps, e hipoki ana i nga korero whanui, te haumaru, te kawe, te whakaahuatanga, te huihuinga, te whakaurunga, te hononga hiko, te mahi, te tiaki, me te rapu raruraru.
Preview Wilo Star Residential Wet Rotor Circulators: Installation and Operating Instructions
Comprehensive installation and operating instructions for Wilo Star Residential Wet Rotor Circulators. Covers safety, technical data, installation, electrical connection, startup, maintenance, and troubleshooting.
Preview Wilo-Star RS, RSD, ST, RSG, AC Tāuta me nga Tohutohu Whakahaere
He aratohu matawhānui mo te whakaurunga, te mahi, me te tiaki o Wilo-Star RS, RSD, ST, RSG, me te AC circulating pumps. Ka hipoki i te haumaru, nga whakaritenga hangarau, te huihuinga, te hononga hiko, te mahi, te rapu raruraru, me nga waahanga e manawapa ana.
Preview Wilo-Star-Z 15 Installation and Operating Instructions
This document provides comprehensive installation, operation, and maintenance guidance for the Wilo-Star-Z 15 circulating pump. It includes safety warnings, technical specifications, intended use, troubleshooting steps, and contact information for Wilo USA and Wilo Canada.
Preview Wilo-Star RS, RSD, ST, RSG, AC Circulating Pump Tāuta me ngā Tohutohu Whakahaere
Ko nga tohutohu whakaurunga me nga tohutohu whakahaere mo te Wilo-Star RS, RSD, ST, RSG, me te raupapa AC o nga papua huri haere. Ka hipoki i nga korero whanui, nga aratohu haumaru, te kawe, te rokiroki, te whakamaarama papu, nga taputapu, te huihuinga, te hononga hiko, te mahi, te tiaki, te rapu raruraru, me nga waahanga e manawapa ana.
Preview Wilo-Star-Z/-ZD Einbau- und Betriebsanleitung
Utu Whakanoho- und Betriebsanleitung für die Wilo-Star-Z/-ZD Zirkulationspumpen, inklusive Sicherheitshinweisen, technischen Daten und Wartungsanleitungen.