The ICM Controls ICM856 is a motor hard start kit designed to enhance the starting performance of single-phase Permanent Split Capacitor (PSC) motors. Utilizing Positive Temperature Coefficient (PTC) technology, this device provides a significant increase in starting torque, up to 500%, facilitating reliable motor startup in various applications. It is suitable for PSC motors ranging from 1/2 hp to 10 hp.

ICM Controls ICM856 Motor Hard Start Kit

Whakaahua 1: ICM Controls ICM856 Motor Hard Start Kit. This image displays the cylindrical hard start kit, primarily black with a blue label visible on the lower portion. The label shows 'CM85' and text indicating it's a 'Relay and Start Capacitor' for PSC units from 1/2 through 10 HP. Wires with connectors extend from the top of the unit.

2. Nga korero haumaru

WHAKATŪPATO: Electrical shock hazard. Installation and servicing should only be performed by qualified personnel. Disconnect all power to the unit before installing or servicing this device. Failure to follow these instructions may result in serious injury or death.

  • Always ensure power is disconnected at the main breaker before beginning any work.
  • Manatoko voltage and current ratings are compatible with the motor and electrical system.
  • Mau taputapu whakamarumaru whaiaro (PPE) e tika ana, tae atu ki nga karaehe haumaru me nga karapu kiriweti.
  • Kaua e hipa i nga taputapu haumaru.

3. Whakatakotoranga

ĀhuahiraTaipitopito
TauiraICM856
Tauira Tuemi9801883
TaupāngaSingle-Phase PSC Motors
Horsepower Range1/2 hp to 10 hp
Torque MultiplierTae atu ki te 500%
HangarauTe Whakawhitinga Temperature Pai (PTC)
Ahu6 x 2 x 2 inihi
Taumaha7.04 hekere
KaihangaNgā Mana Whakahaere ICM

4. Tohutohu Tāuta

  1. Momotu Hiko: Ensure all power to the motor and associated equipment is completely disconnected at the main electrical panel. Verify with a voltage Kaiwhakamatautau.
  2. Locate Motor Run Capacitor: Identify the existing run capacitor on the motor. The ICM856 is designed to work in parallel with this component.
  3. Waea waea: Connect the two wires from the ICM856 in parallel with the motor's run capacitor. This typically involves connecting one wire from the ICM856 to each of the two terminals of the run capacitor. Refer to the motor's wiring diagram for specific connections.
  4. Pūrere Haumaru: Mount the ICM856 securely within the motor's electrical compartment, ensuring it does not interfere with moving parts or other electrical components.
  5. Manatoko Hononga: Double-check all wiring connections for tightness and correct polarity.
  6. Whakaora i te Mana: Kia oti te tāutanga, kia manatokohia hoki, whakahokia te hiko ki te waeine.
  7. Mahi Whakamatau: Observe the motor's startup. It should start more quickly and smoothly.

Tuhipoka: The ICM856 is intended for use only on PSC units. Do not remove any original start components unless specifically instructed by the motor manufacturer.

5. Mahi

The ICM856 operates automatically upon motor startup. When the motor attempts to start, the PTC device within the ICM856 provides an additional surge of current to the motor's start winding, significantly boosting the initial torque. As the motor reaches operating speed, the PTC device's resistance increases rapidly, effectively removing itself from the circuit, allowing the motor to run efficiently on its run capacitor. This process is seamless and requires no user intervention after installation.

6. Tiaki

The ICM856 is a solid-state device and generally requires no routine maintenance. However, periodic inspection of the wiring connections is recommended to ensure they remain secure and free from corrosion.

  • Annually inspect all wiring for signs of wear, fraying, or loose connections.
  • Ensure the device is free from excessive dust, dirt, or moisture accumulation.
  • If the motor exhibits starting issues after installation, first check the ICM856's connections before troubleshooting other motor components.

7. Te Raru

  • Motor Fails to Start:
    • Verify all power connections are secure and correct.
    • Ensure the motor's run capacitor is functioning correctly.
    • Tirohia mo te voltage tuku ki te motini.
    • Confirm the ICM856 is correctly wired in parallel with the run capacitor.
  • Motor Starts Slowly or with Difficulty:
    • Re-check all wiring connections.
    • Ensure the ICM856 is compatible with the motor's horsepower rating (1/2 hp to 10 hp).
    • Inspect the motor itself for mechanical issues or excessive load.
  • Te wera o te taputapu:
    • This is unlikely for a PTC device in normal operation. If overheating occurs, immediately disconnect power and consult a qualified technician. This could indicate incorrect wiring or a fault in the motor or device.

For persistent issues, consult a qualified HVAC or electrical technician.

8. Pūtāhui me te Tautoko

For specific warranty information and technical support regarding your ICM Controls ICM856 Motor Hard Start Kit, please refer to the documentation provided with your purchase or consult the manufacturer's official webpae.

Kaihanga: Ngā Mana Whakahaere ICM

Tuhinga e pa ana - ICM856

Preview ICM325A Single Phase Universal Head Pressure Control Installation Guide
Installation, operation, and application guide for the ICM325A Single Phase Universal Head Pressure Control. Features NFC technology for programming via the ICM Omni App, dual sensor inputs, heat pump bypass, and universal voltage.
Preview ICM401A 3-Phase Monitor: Phase Loss & Reversal Protection Installation Guide
Detailed installation guide and specifications for the ICM401A 3-phase line voltage monitor by ICM Controls. Learn about its operation, troubleshooting, and safety precautions for phase loss and reversal protection.
Preview ICM402 3-Phase Aroturuki: Nga ahuatanga, nga korero, me te waea
Nga korero taipitopito mo te ICM402 3-Phase Monitor, tae atu ki ona ahuatanga, tohu hangarau, me nga hoahoa waea. Ka tiakina e tenei taputapu mai i te ngaronga o te wahanga, te hurihanga o te wahanga, me te kore taurite o te wahanga, he pai mo nga kaikopere.
Preview Aratohu Tāutanga me te Whakahaere i te Mana Pēhanga Pane Ao Whānui Wāhanga Kotahi a ICM325A
Detailed guide for installing, operating, and troubleshooting the ICM325A Single Phase Universal Head Pressure Control by ICM Controls. Features NFC connectivity, universal voltage, and variable fan speed control for HVAC systems.
Preview ICM493-60A Programmable Single-Phase VoltagAratohu Tāutanga o te e Monitor me te Parenga Ngaru
Installation, operation, and application guide for the ICM493-60A programmable single-phase voltage monitor with surge protection by ICM Controls. Includes specifications, wiring diagrams, and setup instructions.
Preview ICM493 Wāhanga-kotahi Whakatakataka VoltagAratohu Tāutanga o te e Monitor me te Parenga Ngaru
He aratohu taipitopito mō te tāuta, te whakahaere, me te whakamahi i te ICM493 Programmable Single-Phase VolttagAroturuki e me te Parenga Ngaru. E kapi ana i te haumaru, ngā mahi tāutanga, te whakatikatika, ngā whakatakotoranga, me ngā mahi pātene mō te HVAC me ngā tono ahumahi.