Exergen 124275S

Exergen TemporalScanner Infrared Thermometer User Manual

Tauira: 124275S

Kupu Whakataki

This manual provides essential information for the proper use, maintenance, and troubleshooting of your Exergen TemporalScanner Infrared Thermometer. This device is designed for accurate measurement of arterial (core) temperature, offering a reliable alternative to traditional oral, rectal, and tympanic methods.

The Exergen TemporalScanner, model 124275S, is a clinical-grade instrument widely used in professional healthcare settings due to its precision and ease of use.

Ka mutu te huaview

Exergen TemporalScanner Infrared Thermometer showing LCD display with 37.4 degrees Celsius reading and a label for cleaning instructions.

Figure 1: Exergen TemporalScanner Infrared Thermometer. The image displays the device with its sensor head, main body, and digital display showing "37.4". A label on the device indicates "Dirty lens = low temps" and provides instructions to "Clean center lens every two weeks with Q-tip and alcohol."

The Exergen TemporalScanner measures temperature by scanning the temporal artery on the forehead. Key features include:

Tatūnga

Tāuta Pūhiko

The Exergen TemporalScanner requires one 9V battery for operation. To install or replace the battery:

  1. Locate the battery compartment cover, typically on the back or bottom of the device.
  2. Whakatuwheratia te uhi o te wahanga.
  3. Whakauruhia he pākahiko 9V hou, kia tika ai te polarity (+/-).
  4. Katia kia mau te uhi o te wahanga pākahiko.

Tirohanga Tuatahi

Before first use, inspect the device for any visible damage. Ensure the sensor lens is clean and free of debris. Refer to the Maintenance section for cleaning instructions.

Nga Tohutohu Whakahaere

For accurate temperature measurement, follow these steps:

  1. Turanga: Place the sensor head gently on the center of the forehead, midway between the eyebrow and the hairline.
  2. Whakahohehia te Matawai: Press and hold the scan button (often a large, prominent button on the device body).
  3. Scan Motion: While holding the button, slowly slide the thermometer straight across the forehead to the hairline, then lift it off the forehead.
  4. Panui Pawera: Release the scan button. The temperature reading will be displayed on the LCD screen.

Tuhipoka: For optimal accuracy, ensure the skin is dry and free of obstructions like hair or sweat. If the patient is sweating, scan behind the earlobe on the neck for a more accurate reading.

Te tiaki

Cleaning the Sensor Lens

A dirty sensor lens can lead to inaccurate or low temperature readings. It is recommended to clean the center lens every two weeks, or more frequently if needed.

General Cleaning and Disinfection

The device is made of chemically resistant materials, allowing for effective disinfection.

Rokiroki

Store the thermometer in a clean, dry place at room temperature, away from direct sunlight and extreme temperatures.

Raparongoā

RaruraruTake peaRongoā
Inaccurate or Low ReadingsDirty sensor lens; improper scanning technique; patient sweating.Clean the sensor lens as per Maintenance section. Ensure proper scanning technique. If sweating, scan behind the earlobe.
No Display/Device Not Turning OnKua mate, kua hē ranei te whakaurunga o te pākahiko.Whakakapia te pākahiko 9V, kia tika ai te polarity.
Karere Hapa kei runga WhakaatuDevice malfunction or environmental issue.Refer to the specific error code in the full product manual (if available) or contact customer support. Try re-scanning.

Whakatakotoranga

ĀhuahiraTaipitopito
Tau tauira124275S
WaitohuExergen
Momo WhakaatuMamati
Puna Mana1 x 9V Battery (required)
Āhuahira MotuhakeTika Teitei
Tae
Rauemi o wahoKirihou
Nga Waahanga kei rotoThermometer, battery, sample covers
Hangarau HonongaNihokikorangi
Ahu mōkihi9.45 x 6.65 x 2.83 inihi
Taumaha Tūemi7.51 hekere
KaihangaExergen

Pūtāhui me te Tautoko

Nga korero Whakaputanga

The Exergen TemporalScanner is protected by a PUTANGA ORA, reflecting the manufacturer's confidence in its rugged and reliable construction.

Tautoko Kiritaki

For further assistance, technical support, or warranty claims, please contact Exergen customer service. Refer to the official Exergen webte waahi, te kohinga hua ranei mo nga korero whakapiri o naianei.

Tuhinga e pa ana - 124275S

Preview Exergen TAT-5000S-RS232 Series Multi-Language Operation Manual
Comprehensive operation manual for the Exergen TAT-5000S-RS232 Temporal Artery Thermometer, detailing its features, usage, safety instructions, and maintenance for medical professionals.
Preview Exergen TAT-5000 TemporalScanner Infrared Thermometer Te Pukapuka a te Kaiwhakahaere
He pukapuka a te Kaiwhakahaere mo te Exergen TAT-5000 TemporalScanner, he ine ine wera pokākā a-ringa mo te ine tika me te ngawari o te pāmahana o te rae. Kei roto ko nga tohutohu haumaru, nga tikanga whakahaere, te tiaki me te tiaki, te rapu raruraru, nga whakaritenga, me nga whakapuakanga hototahi hiko.
Preview Exergen TemporalScanner TAT-5000S-RS232-CORO Pukapuka Whakahaere
He pukapuka a te Kaiwhakahaere mo te Exergen TemporalScanner TAT-5000S-RS232-CORO, he inemahana infrared a-ringa mo nga tohunga rongoa. Kei roto ko nga tohutohu mo te whakamahi, nga korero haumaru, te tiaki me te tiaki, nga whakaritenga, me nga raraunga hototahi hiko.
Preview Exergen TAT-5000S-RS232 TemporalScanner Manual Mahi
He pukapuka mahi matawhānui mo te Exergen TAT-5000S-RS232 TemporalScanner, he inemahana o te anga-a-te-a-tinana. Ka hipoki i nga ahuatanga, nga tohutohu haumaru, te whakamahinga, te tiaki, te tiaki, te rapu raruraru, me nga whakaritenga hangarau.
Preview Exergen TemporalScanner TAT-2000 me te Nihokikorangi: Te Pukapuka Kaiwhakamahi me nga Whakaritenga
Te pukapuka a-whakamahi matawhānui me nga whakaritenga hangarau mo te Exergen TemporalScanner TAT-2000 me te ine wera infrared Nihokikorangi, e whakaatu ana i tona whakamahinga, nga ahuatanga, nga korero haumaru, me te tika o te haumanu.
Preview Exergen TemporalScanner TAT-2000C/Original Home Model: Instructions for Use
Comprehensive instructions for the Exergen TemporalScanner TAT-2000C/Original Home Model, covering setup, usage, safety precautions, FAQs, and specifications for accurate temporal artery temperature measurement.