1. Kupu Whakataki
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Legrand LEG04704 Multifunction Timer. Please read these instructions carefully before installation and retain them for future reference.
The Legrand LEG04704 is a single-module multifunction timer designed for controlling lighting circuits with adjustable timing and various load types. It operates on a 230V~ 50/60Hz power supply and provides a 16A 250V output.
2. Nga Hua o te Hua
- Module Count: 1 module.
- Tuku Hiko: 230 V~ 50/60 Hz.
- Putanga: 16 A - 250 V~ (cos φ = 1).
- Adjustable Timing: Mai i te 0.5 ki te 12 meneti.
- Uta Hototahi:
- Koretake lamps: 3680w
- Hāroto lamps (230 V~): 2000 W
- Hāroto lamps with ferromagnetic transformer: 500 W
- Hāroto lamps with electronic transformer: 2000 W
- Korewharewha kiato lamps: 1000 VA
- Korewharewha lamps (parallel compensated, ≤ 100 µF): 1000 VA
- Tiaki-whakaora lamps: 1000w
- Waea waea: Automatic recognition for 3 or 4-wire operation.
- Ngā Tāuru Mana: Separate inputs (8-230V) for presence detection or intercom lighting control.
- Nga Mahi: End-of-timing pre-warning, 1-hour long duration function, and manual override.
- Parenga: Self-protection mechanism in case of a blocked push-button.
- Hototahi: Accepts supply busbars.
- Taiao: Nga rauemi hangarua.
3. Nga korero haumaru
WHAKATŪPATO: Electrical installation should only be performed by qualified personnel in accordance with national wiring regulations and safety standards.
- Always disconnect the main power supply before performing any installation, maintenance, or wiring work.
- Me whakarite kia tika te whenua ina hiahiatia.
- Do not exceed the specified load ratings for the timer.
- Tiakina te taputapu mai i te makuku, te puehu, me te wera nui.
- Manatokona kei te mau nga hononga katoa i mua i te whakahokinga hiko.
4. Tāutanga
The Legrand LEG04704 timer is designed for DIN rail mounting within an electrical enclosure.

Image showing the Legrand LEG04704 multifunction timer. It is a grey, single-module device designed for DIN rail mounting. Visible features include screw terminals labeled 'N' and 'B' at the top, a timing adjustment dial marked from 0.5 to 12 minutes, and a manual override switch below it. The Legrand logo and model number '0047 04' are also visible. Lower terminals are labeled 'L' and '4'.
4.1. Whakapiki
- Ensure the main power supply to the installation is disconnected.
- Clip the timer onto a standard DIN rail inside a suitable electrical enclosure.
4.2. Hononga Waea
Refer to the wiring diagram provided with the product and the labels on the device. The timer automatically recognizes 3 or 4-wire operation.
- N: Neutral connection.
- B: Input for control push-button (e.g., from a switch or presence detector).
- L: Live (Phase) input connection.
- 4: Switched Live (Phase) output to the load (e.g., lighting circuit).
Ensure all wire connections are tight and secure. Use appropriate wire gauges for the load current.
5. Nga Tohutohu Whakahaere
5.1. Setting the Timer Duration
The timing duration can be adjusted using the rotary dial on the front of the device. Use a small screwdriver to turn the dial to the desired time setting, ranging from 0.5 minutes to 12 minutes.
5.2. Manual Override Switch
The timer features a manual override switch, typically located below the timing dial. This switch allows for continuous operation or manual OFF, bypassing the timed function. Refer to the symbols on the device for specific positions (e.g., timed operation, continuous ON, continuous OFF).
5.3. Nga Mahi Motuhake
- Pre-warning Function: The timer may provide a visual indication (e.g., a brief flicker of the light) before the end of the timing period, allowing users to react before the light switches off.
- Long Duration Function: A specific input or sequence might activate a 1-hour timing period, useful for extended lighting needs.
6. Tiaki
The Legrand LEG04704 timer requires minimal maintenance.
- Me whakarite kia momotu te pūnaha hiko i mua i te horoinga.
- Horoia te waho ki te kakahu ngohengohe, maroke. Kaua e whakamahi i nga kai horoi me nga whakarewa.
- There are no user-serviceable parts inside the device. Do not attempt to open or repair the timer.
7. Te Raru
- Timer not activating:
- Check if the main power supply is connected and active.
- Verify all wiring connections (L, N, B, 4) are correct and secure.
- Ensure the control push-button is functioning correctly.
- Check the manual override switch position.
- Incorrect timing duration:
- Adjust the rotary dial to the desired time setting.
- Load not switching off:
- Check the manual override switch position; it might be set to continuous ON.
- Ensure the load does not exceed the maximum specified rating.
- If issues persist, consult a qualified electrician or contact Legrand customer support.
8. Whakatakotoranga
| Waitohu | Legrand |
| Tauira | LEG04704 |
| Tuku Hiko | 230 V ~ 50/60 Hz |
| Putanga o naianei | 16 A |
| Putanga Voltage | 250 V~ (cos φ = 1) |
| Awhe Wā | 0.5 ki te 12 meneti |
| Rahi Kōwae | 1 kōwae |
| Rauemi | PVC |
| Tae | Kerei |
| Taumaha Tūemi | 92 Karamu |
| GTIN | 03245060047047 |
9. Pūtāhui me te Tautoko
Legrand products are manufactured to high-quality standards and are covered by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Legrand webpae.
For technical support, troubleshooting assistance, or inquiries regarding your Legrand LEG04704 Multifunction Timer, please contact Legrand customer service through their official channels.