VEMER VE339800

VEMER VE339800 MEMO DW Digital Time Switch User Manual

Tauira: VE339800

1. Kupu Whakataki

This manual provides instructions for the installation, setup, and operation of the VEMER VE339800 MEMO DW Digital Time Switch. This device is designed for precise management of electrical loads through daily or weekly programming. It features a large display for clear information and an NFC interface for convenient programming via a smartphone application.

2. Nga korero haumaru

WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel in accordance with local electrical codes and regulations.

  • Momotuhia i nga wa katoa te hiko i mua i te whakauru, te mahi ranei i te taputapu.
  • Me whakarite te turanga tika.
  • Kaua e tukuna te taputapu ki te makuku, ki te wera nui ranei.
  • Manatokona kei te mau nga hononga katoa i mua i te whakahokinga hiko.
  • I hangaia te taputapu mo te whakamahi o roto anake.

3. Hua Neke Atuview

The VEMER MEMO DW is a digital time switch for controlling electrical circuits. It offers flexible programming options and user-friendly features.

VEMER VE339800 MEMO DW Digital Time Switch

Whakaahua 1: Mua view of the VEMER VE339800 MEMO DW Digital Time Switch, showing the display and control buttons.

Āhuatanga matua:

  • Whakaaturanga Mamati: Large, backlit LCD showing date, time, and relay status.
  • Papatonotanga: Daily or weekly scheduling for ON/OFF events and pulse functions.
  • NFC Interface: Allows programming transfer from a smartphone using a dedicated application.
  • Automatic Daylight Saving: Adjusts automatically for seasonal time changes.
  • Pūrua Pūhiko: Internal battery preserves settings during power outages; replaceable via a flap.
  • Putanga: 1 changeover relay, 16A.

Ihirangi mōkī:

  • VEMER VE339800 MEMO DW Digital Time Switch (1 unit)
  • Pukapuka Tohutohu (tenei tuhinga)

4. Tāutanga

The VEMER MEMO DW is designed for DIN rail mounting (2 modules).

4.1 Whakapiki

  1. Ensure power to the electrical panel is disconnected.
  2. Locate an available 2-module space on the DIN rail.
  3. Clip the time switch onto the DIN rail until it securely locks into place.

4.2 Hononga Hiko

Refer to the wiring diagram provided on the device or in the detailed technical documentation. The device requires a 230V power supply.

  • Connect the phase (L) and neutral (N) wires to the designated power input terminals.
  • Connect the load to be controlled to the relay output terminals (common, normally open, normally closed). The device has 1 changeover relay (16A).
  • Ensure all connections are tight and correctly insulated.

CAUTION: Incorrect wiring can damage the device or connected equipment and poses a fire hazard.

5. Tatūnga Tuatahi

After installation and power-up, the device will require initial configuration.

Close-up of VEMER MEMO DW display and buttons

Whakaahua 2: Whakatata view of the VEMER MEMO DW display and control buttons (Left arrow, C1, C2, OK).

5.1 Te Whakaritenga i te Ra me te Wa

  1. Upon first power-up or after a long power outage (if the battery is depleted), the display will prompt for date and time settings.
  2. Use the navigation buttons (usually indicated by arrows or C1/C2) to adjust the values (year, month, day, hour, minute).
  3. Press the "OK" button to confirm each setting and move to the next.

5.2 Te Kōwhiringa Reo

The device allows for language selection. Follow the on-screen prompts or refer to the detailed manual for specific button sequences to access the language menu.

5.3 Automatic Daylight Saving Time

The VEMER MEMO DW supports automatic adjustment for daylight saving time. This feature can typically be enabled or disabled in the settings menu. Ensure it is configured according to your local requirements.

6. Operation and Programming

The time switch offers various programming modes to control your electrical loads.

6.1 Basic ON/OFF Programming

This mode allows you to set specific times for the relay to turn ON and OFF.

  1. Access the programming menu (refer to the device's on-screen instructions or full manual for button sequence).
  2. Select "New Program" or similar option.
  3. Choose the desired day(s) of the week for the program to apply (e.g., daily, weekdays, weekends, specific days).
  4. Set the ON time (hour and minute).
  5. Set the OFF time (hour and minute).
  6. Confirm and save the program.

6.2 Pulse Programming

The pulse function allows the relay to activate for a short, predefined duration.

  1. In the programming menu, select the pulse program option.
  2. Set the start time for the pulse.
  3. Define the duration of the pulse (e.g., seconds).
  4. Select the day(s) of the week.
  5. Whakaū ka tiaki.

6.3 Whakakore a-ringa

The device typically includes a manual override function to temporarily change the relay state (ON/OFF) independently of the programmed schedule. Consult the device's interface for the specific button or menu option to activate this feature.

7. NFC Programming

The VEMER MEMO DW features an NFC (Near Field Communication) interface, allowing for convenient programming via a dedicated smartphone application.

Smartphone with VEMER Memo app and NFC logo next to the time switch

Figure 3: Illustrates smartphone NFC programming with the VEMER Memo app.

7.1 Te Whakamahi i te Taupānga Waea Atamai

  1. Download the official VEMER Memo app from your smartphone's app store.
  2. Open the app and create your desired programming schedule.
  3. Activate NFC on your smartphone.
  4. Place your smartphone near the NFC symbol on the VEMER MEMO DW device.
  5. The app will transfer the program to the time switch. Follow any on-screen prompts on your phone or the device.

NOTE: Ensure your smartphone's NFC functionality is enabled and correctly positioned for successful data transfer. Some users report needing multiple attempts for successful transfer.

7.2 Keypad Lock Function

To prevent unauthorized changes to the device's settings, the keypad can be locked with a password.

  1. Access the security settings menu on the device.
  2. Enable the keypad lock function.
  3. Set a unique password using the navigation buttons.
  4. To unlock, enter the password when prompted.

8. Tiaki

8.1 Whakakapinga Pūhiko

The VEMER MEMO DW contains an internal backup battery to retain settings during power outages. When the battery is depleted, it can be replaced.

  1. Disconnect power to the device before attempting battery replacement.
  2. Locate the battery compartment flap on the device (usually on the front or side).
  3. Open the flap and carefully remove the old battery.
  4. Whakauruhia he pākahiko hou he rite te momo me nga whakaritenga.
  5. Close the battery compartment flap securely.
  6. Dispose of the old battery responsibly according to local regulations.

8.2 Te horoi

Horoia te taputapu ki te kakahu ngohengohe, maroke. Kaua e whakamahi i nga kai horoi me nga whakarewa.

9. Te Raru

RaruraruTake peaRongoā
He waatea te whakaaturanga.No power supply; depleted backup battery.Check power connections. Replace backup battery if necessary.
Programs are not executing.Incorrect programming; manual override active; keypad locked.Verify program settings. Deactivate manual override. Unlock keypad.
NFC programming fails.NFC not enabled on phone; phone not positioned correctly; app issue.Ensure NFC is active. Reposition phone. Restart app. Try manual programming.
Time/Date is incorrect after power outage.Depleted backup battery.Replace backup battery. Reset time and date.

10. Whakatakotoranga

ĀhuahiraTaipitopito
Tau tauiraVE339800
Tuku Hiko230 V
Putanga1 changeover relay, 16 A
PapatonotangaDaily or Weekly, ON/OFF, Pulse
AtangaNFC for smartphone programming
WhakaatuWhakamuri LCD
TāutatangaDIN rail (2 modules)
Ahu (L x W x H)3.6 x 6.5 x 9 cm
Taumaha130 karamu
RauemiKirihou
Tae
TaketakeItari

11. Pūtāhui me te Tautoko

VEMER products are manufactured to high-quality standards. This product is covered by the manufacturer's standard warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official VEMER webpae.

For technical support, troubleshooting assistance, or spare parts inquiries, please contact VEMER customer service through their official channels. When contacting support, please have your product model number (VE339800) and purchase information readily available.

Tuhinga e pa ana - VE339800

Preview Rau Raraunga Hangarau o te Vemer MKCT032-2013 Chronothermostat Mamati
He whārangi raraunga hangarau whānui mō te chronothermostat mamati ā-wiki Vemer MKCT032-2013, e whakaatu ana i ngā āhuatanga, ngā whakaritenga, me ngā tawhā whakahaere mō te whakahaere pāmahana tika me te whai huatanga o te pūngao.
Preview Pukapuka Kaiwhakamahi mō te Vemer ThermoPro Mod. 1 Chronotherm mō ngā Pāreti
He pukapuka kaiwhakamahi whānui mō te Vemer ThermoPro Mod. He chronotherm ia wiki, e whakaatu ana i te tāutanga, te hōtaka, te whakahaere, me ngā āhuatanga matatau mō te whakahaere whakamahana radiator.
Preview Vemer Pūrere Mana Huarere: Thermostats, Chronothermostats, and Humidistats Catalog
Tūhurahia te rārangi matawhānui a Vemer mo nga rongoā whakahaere huarere matatau, e whakaatu ana i te whānuitanga o nga whakamaaramatanga, te whakamaarama hau, me te whakamaarama i hangaia mo nga kaainga me nga whare hou. Tirohia nga ahuatanga hou me te hoahoa Itari kounga.
Preview Vemer: Catalogo Cronotermostati, Termostati e Umidostati per il Controllo Clima
Esplora la vasta gamma di soluzioni Vemer per il controllo climatico: cronotermostati digitali, termostati elettronici e meccanici, umidostati e accessori. Scopri funzionalità avanzate per la gestione efficiente della temperatura e dell'umidità in ambienti residenziali e commerciali.
Preview Ngā Pūrere Whakahaere Āhuarangi o Vemer: Ngā Paerewa me ngā Paerewa Chronothermostat
Tūhurahia te whānuitanga o ngā Vemer o ngā chronothermostat mamati, ngā thermostat hiko, ngā thermostat mīhini, me ngā haumākū mō te whakahaere āhuarangi matatau o te kāinga. Kei roto ko ngā tauira pēnei i a Iride, Dafne, Tuo, Chronos, Mithos, me ētahi atu, i hangaia mō te whai huatanga me te whakamarie.
Preview Pukapuka Kaiwhakamahi mō te Vemer ThermoPro Programmable Radiator Thermostat
He pukapuka ā-ringa mō te Vemer ThermoPro radiator programmable thermostat (tauira VE740700). Akohia te tāutanga, te hōtaka, ngā mahi, me ngā āhuatanga haumaru mō te whakahaere pai o te whakamahana kāinga.