Wilo Yonos Pico 25/1-6

Pukapuka Kaiwhakamahi mō te Papu Hurihuri ā-Whare Wilo Yonos Pico 25/1-6

1. Kupu Whakataki

This user manual provides essential information for the safe and efficient installation, operation, and maintenance of the Wilo Yonos Pico 25/1-6 domestic circulator pump. This high-efficiency pump is designed for hot water heating, air conditioning, and industrial circulation systems. Please read these instructions thoroughly before commencing any work with the pump.

Wilo Yonos Pico 25/1-6 Domestic Circulator Pump

Figure 1: Wilo Yonos Pico 25/1-6 Domestic Circulator Pump. The image shows the green pump housing connected to a silver-grey control unit with a digital display and a red rotary knob.

2. Nga Tohutohu Haumaru

Failure to follow these safety instructions may result in personal injury or damage to the equipment. Keep this manual accessible for future reference.

3. Hua Neke Atuview

The Wilo Yonos Pico 25/1-6 is a high-efficiency, electronically controlled circulator pump designed for various heating and air conditioning applications. Its compact design and advanced features ensure reliable and energy-efficient operation.

Āhuatanga matua:

4. Tāutanga

Proper installation is crucial for the pump's performance and longevity. Always ensure the system is depressurized and drained before installation.

Hipanga Tāuta:

  1. Tūnga Whakapuru: Install the pump in a horizontal position with the motor shaft horizontal. Ensure sufficient space for ventilation and maintenance.
  2. Hononga Paipa: Connect the pump to the piping system using appropriate fittings. Ensure all connections are watertight. Avoid mechanical stress on the pump from the piping.
  3. Hononga Hiko: Connect the pump to the electrical supply according to the wiring diagram provided with the product and local electrical regulations. Ensure proper grounding. The pump operates on 230 Volts (AC).
  4. Filling and Venting: After installation, fill the system with the appropriate fluid and vent the pump thoroughly to remove any trapped air.

5. Tatūnga Tuatahi

Once installed and electrically connected, the pump requires initial setup.

  1. Whakahiko: Restore power to the pump. The digital display will illuminate.
  2. Kōwhiringa Aratau Mahi: Use the rotary knob on the control unit to select the desired operating mode (e.g., constant differential pressure, variable differential pressure, fixed speed). Refer to the pump's specific display icons for mode identification.
  3. Whakatikatika Tautuhinga: Adjust the required head or speed setting using the rotary knob. The display will show the current setting or power consumption.

6. Mahi

The Wilo Yonos Pico 25/1-6 is designed for continuous operation. Once set up, it will automatically adjust its performance based on the selected operating mode and system requirements.

7. Tiaki

The Wilo Yonos Pico 25/1-6 is largely maintenance-free. However, periodic checks can help ensure optimal performance and extend its lifespan.

8. Te Raru

I mua i te whakapā atu ki te tautoko hangarau, review nga take noa e whai ake nei me o raatau otinga ka taea.

RaruraruTake peaRongoā
Kaore e timata te papuNo power supply; electrical fault; seized rotorCheck power connection and circuit breaker; consult an electrician; attempt to free rotor (if accessible and safe).
Insufficient flow/pressureAir in system; incorrect operating mode/setting; clogged filterVent the system; adjust pump settings; check and clean system filter.
Haruru/wiriwiri rerekeAir in system; cavitation; foreign object in pump; improper mountingVent the system; check system pressure; inspect pump for obstructions; ensure secure mounting.
Waehere hapa i te whakaaturangaHapa ā-roto motuhakeRefer to the pump's detailed error code list (if available in separate documentation) or contact Wilo service.

9. Whakatakotoranga Hangarau

WhakatakotorangaUara
KaihangaWILO
Tauira Tohutoro4164026/14W01
RauemiTe rino, te kowiri tira
Puna ManaTauera Hiko
Voltage230 Volts (AC)
Rere Rere Morahi2.5 Cubic Meters per hour
Taumaha Tūemi2.16 Kirokaramu
Ahu mōkihi19 x 19 x 11 cm
KāhuaKi Runga o te Papa
Nga Pikohiko e hiahiatia anaKao
Nga waahanga e waatea anaKaore i te waatea nga korero

10. Pūtāhui me te Tautoko

For warranty information, please refer to the documentation provided with your purchase or contact your seller. For technical support or inquiries regarding spare parts, please contact Wilo customer service or an authorized Wilo service partner.

Kaihanga: WILO

Tauira: Yonos Pico 25/1-6

Tohutoro: 4164026/14W01

Tuhinga e pa ana - Yonos Pico 25/1-6

Preview Wilo-Yonos PICO1.0 Circulator Pump: Installation & Operation Guide
Ko tenei tuhinga he korero potoview and quick guide for the Wilo-Yonos PICO1.0 circulator pump, a high-efficiency solution designed for hot-water heating systems. Key information includes essential safety guidelines, installation procedures, and operational best practices.
Preview Wilo-Yonos PICO Installation and Operating Instructions
Detailed guide for installing and operating the Wilo-Yonos PICO high-efficiency circulator pump. Covers safety, technical data, installation, commissioning, maintenance, and troubleshooting for optimal performance.
Preview Wilo-Yonos PICO Installation and Operating Instructions
Comprehensive guide for installing, operating, and maintaining the Wilo-Yonos PICO high-efficiency circulator pump. Includes technical data, safety information, troubleshooting, and commissioning procedures.
Preview Wilo-Yonos MAXO/-D/-Z Installation and Operating Instructions
Comprehensive guide for the installation, operation, and maintenance of Wilo-Yonos MAXO, MAXO-D, and MAXO-Z circulator pumps. Covers safety, technical specifications, and troubleshooting for heating, cooling, and hot water systems.
Preview Wilo-Yonos PICO: Ngā Tohutohu Tāutanga me te Whakahaere
He aratohu tere mō te tāuta me te whakahaere i te papu hurihuri Wilo-Yonos PICO. Kei roto ko te haumaru, te tāutanga, me te whakahaere mō ngā pūnaha whakamahana wai wera. Kei te ipurangi te pukapuka katoa.
Preview Wilo-Yonos MAXO/-D/-Z Installation and Operating Instructions Manual
Comprehensive installation and operating instructions for the Wilo-Yonos MAXO, MAXO-D, and MAXO-Z series circulation pumps. Covers safety, installation, electrical connection, operation, maintenance, and troubleshooting.