1. Kupu Whakataki
This user manual provides essential information for the safe and efficient installation, operation, and maintenance of the Wilo Yonos Pico 25/1-6 domestic circulator pump. This high-efficiency pump is designed for hot water heating, air conditioning, and industrial circulation systems. Please read these instructions thoroughly before commencing any work with the pump.

Figure 1: Wilo Yonos Pico 25/1-6 Domestic Circulator Pump. The image shows the green pump housing connected to a silver-grey control unit with a digital display and a red rotary knob.
2. Nga Tohutohu Haumaru
Failure to follow these safety instructions may result in personal injury or damage to the equipment. Keep this manual accessible for future reference.
- Kaimahi Tohu: Installation and maintenance must only be performed by qualified and authorized personnel in accordance with local regulations and standards.
- Haumaru Hiko: Ensure the power supply is disconnected before any installation or maintenance work. All electrical connections must comply with local electrical codes.
- Hot Surfaces/Water: The pump and connected pipes may become hot during operation. Allow the system to cool down before handling.
- Tepe Mahi: Do not operate the pump outside its specified operating limits (voltage, temperature, pressure).
- Parenga: Ensure the pump is protected from frost and direct exposure to weather elements.
3. Hua Neke Atuview
The Wilo Yonos Pico 25/1-6 is a high-efficiency, electronically controlled circulator pump designed for various heating and air conditioning applications. Its compact design and advanced features ensure reliable and energy-efficient operation.
Āhuatanga matua:
- Simple circulation pump for heating and air conditioning systems.
- High-efficiency motor with electronic control.
- Digital display for operational status and settings.
- User-friendly interface with a rotary knob for adjustments.
4. Tāutanga
Proper installation is crucial for the pump's performance and longevity. Always ensure the system is depressurized and drained before installation.
Hipanga Tāuta:
- Tūnga Whakapuru: Install the pump in a horizontal position with the motor shaft horizontal. Ensure sufficient space for ventilation and maintenance.
- Hononga Paipa: Connect the pump to the piping system using appropriate fittings. Ensure all connections are watertight. Avoid mechanical stress on the pump from the piping.
- Hononga Hiko: Connect the pump to the electrical supply according to the wiring diagram provided with the product and local electrical regulations. Ensure proper grounding. The pump operates on 230 Volts (AC).
- Filling and Venting: After installation, fill the system with the appropriate fluid and vent the pump thoroughly to remove any trapped air.
5. Tatūnga Tuatahi
Once installed and electrically connected, the pump requires initial setup.
- Whakahiko: Restore power to the pump. The digital display will illuminate.
- Kōwhiringa Aratau Mahi: Use the rotary knob on the control unit to select the desired operating mode (e.g., constant differential pressure, variable differential pressure, fixed speed). Refer to the pump's specific display icons for mode identification.
- Whakatikatika Tautuhinga: Adjust the required head or speed setting using the rotary knob. The display will show the current setting or power consumption.
6. Mahi
The Wilo Yonos Pico 25/1-6 is designed for continuous operation. Once set up, it will automatically adjust its performance based on the selected operating mode and system requirements.
- Aroturuki: Periodically check the digital display for current operating status and any error codes.
- Whakatikatika: If system requirements change, you can re-adjust the operating mode or settings using the rotary knob.
- Whakaweto Raro: To temporarily stop the pump, disconnect its power supply. For extended periods of non-use, follow maintenance guidelines for storage.
7. Tiaki
The Wilo Yonos Pico 25/1-6 is largely maintenance-free. However, periodic checks can help ensure optimal performance and extend its lifespan.
- Tirotiro Ataata: Regularly inspect the pump for any signs of leaks, corrosion, or unusual wear.
- Pēhanga Pūnaha: Ensure the system pressure is within the recommended range for the pump.
- Te horoi: Keep the exterior of the pump and the control unit clean and free from dust and debris to ensure proper ventilation.
- Te takurua: If the pump is installed in an area prone to freezing temperatures and the system is shut down, ensure the pump and pipes are drained to prevent frost damage.
8. Te Raru
I mua i te whakapā atu ki te tautoko hangarau, review nga take noa e whai ake nei me o raatau otinga ka taea.
| Raruraru | Take pea | Rongoā |
|---|---|---|
| Kaore e timata te papu | No power supply; electrical fault; seized rotor | Check power connection and circuit breaker; consult an electrician; attempt to free rotor (if accessible and safe). |
| Insufficient flow/pressure | Air in system; incorrect operating mode/setting; clogged filter | Vent the system; adjust pump settings; check and clean system filter. |
| Haruru/wiriwiri rereke | Air in system; cavitation; foreign object in pump; improper mounting | Vent the system; check system pressure; inspect pump for obstructions; ensure secure mounting. |
| Waehere hapa i te whakaaturanga | Hapa ā-roto motuhake | Refer to the pump's detailed error code list (if available in separate documentation) or contact Wilo service. |
9. Whakatakotoranga Hangarau
| Whakatakotoranga | Uara |
|---|---|
| Kaihanga | WILO |
| Tauira Tohutoro | 4164026/14W01 |
| Rauemi | Te rino, te kowiri tira |
| Puna Mana | Tauera Hiko |
| Voltage | 230 Volts (AC) |
| Rere Rere Morahi | 2.5 Cubic Meters per hour |
| Taumaha Tūemi | 2.16 Kirokaramu |
| Ahu mōkihi | 19 x 19 x 11 cm |
| Kāhua | Ki Runga o te Papa |
| Nga Pikohiko e hiahiatia ana | Kao |
| Nga waahanga e waatea ana | Kaore i te waatea nga korero |
10. Pūtāhui me te Tautoko
For warranty information, please refer to the documentation provided with your purchase or contact your seller. For technical support or inquiries regarding spare parts, please contact Wilo customer service or an authorized Wilo service partner.
Kaihanga: WILO
Tauira: Yonos Pico 25/1-6
Tohutoro: 4164026/14W01