GREISINGER GPHU 014 MP/BNC

GREISINGER Moko

Pukapuka Tohutohu mō te Kaitahuri Ine pH Greisinger GPHU 014 MP/BNC

Model: GPHU 014 MP/BNC

1. Kupu Whakataki

This manual provides comprehensive instructions for the safe and efficient operation of your Greisinger GPHU 014 MP/BNC pH Measurement Converter. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage. Keep this manual for future reference.

The GPHU 014 MP/BNC is designed to convert pH electrode signals into a standardized output, allowing for precise pH monitoring in various applications. It is intended for use with compatible pH electrodes featuring a BNC connector.

2. Nga korero haumaru

  • Always operate the device within its specified environmental conditions.
  • Kaua e tukuna te taputapu ki te wera nui, te ra tika, te makuku nui ranei.
  • A ape i te tuku, te tuku ranei i te taputapu ki nga paanga kaha.
  • Ensure proper electrical connections are made according to the instructions to prevent electrical shock or damage.
  • Kaua e ngana ki te whakatuwhera, ki te whakatika ranei i te taputapu. Tukuna atu nga ratonga katoa ki nga kaimahi whai tohu.
  • Use only compatible pH electrodes and accessories with this converter.
  • Dispose of the device and any associated components in accordance with local environmental regulations.

3. Ihirangi mokete

Please check the package contents upon receipt. If any items are missing or damaged, contact your supplier immediately.

  • Greisinger GPHU 014 MP/BNC pH Measurement Converter
  • Pukapuka Tohutohu (tenei tuhinga)
  • Mounting accessories (if applicable, check packaging)

Note: A pH electrode is not included with this converter and must be purchased separately.

4. Hua Neke Atuview

The Greisinger GPHU 014 MP/BNC is a compact and robust pH measurement converter designed for industrial and laboratory applications. It features a clear digital display and intuitive controls for easy operation.

Greisinger GPHU 014 MP/BNC pH Measurement Converter front view

Whakaahua 1: Mua view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter. The display shows "7.46 pH" and includes "ATC" and "Temp" indicators. Below the display are three buttons labeled "SET 1", "▼ 2", and "▲ 3". A BNC connector is visible on the right side for electrode connection. Two small ports are visible at the bottom.

Greisinger GPHU 014 MP/BNC pH Measurement Converter side view

Whakaahua 2: Te taha view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter, highlighting the BNC connector and the robust housing. The connector is labeled "AMPHENOL".

Wae matua:

  • Whakaaturanga Mamati: Shows pH value, temperature, and status indicators.
  • SET Button (1): Hei whakauru me te whakaū i ngā tautuhinga.
  • Down Button (2): Used to navigate menus and decrease values.
  • Up Button (3): Used to navigate menus and increase values.
  • BNC Connector: For connecting a compatible pH electrode.
  • Whakauru Hiko: (Location not visible in images, refer to device for exact position)

5. Tatūnga

5.1. Whakapiki

The converter can be mounted using the integrated mounting points (screws visible in Figure 1). Ensure the mounting location is stable, free from excessive vibration, and within the specified operating temperature range.

5.2. Connecting the pH Electrode

  1. Ensure the converter is powered off.
  2. Carefully connect your pH electrode's BNC connector to the BNC input on the right side of the GPHU 014 MP/BNC converter (refer to Figure 1 and 2).
  3. Ensure the connection is secure but do not overtighten.

5.3. Hononga Mana

Connect the appropriate power supply to the converter. Refer to the device labeling for specific voltage and current requirements. Ensure the power source is stable and matches the device's specifications.

5.4. Whakatairanga Tuatahi

Before first use, or after prolonged storage, the pH converter and electrode system must be calibrated. Refer to your pH electrode's manual for specific calibration buffer requirements.

  1. Whakawerahia te taputapu.
  2. Access the calibration menu using the SET button. (Specific steps may vary, consult the device's on-screen prompts or a more detailed technical manual if available).
  3. Follow the on-screen instructions to perform a 2-point or 3-point calibration using standard pH buffer solutions (e.g., pH 4.01, 7.00, 10.01).
  4. Rinse the electrode thoroughly with distilled water between buffer solutions.
  5. Confirm calibration settings.

6. Mahi

6.1. Te Whanganga i tetahi Ine

  1. Ensure the pH electrode is properly connected and calibrated.
  2. Immerse the pH electrode into the sample solution, ensuring the sensing bulb and reference junction are fully submerged.
  3. Allow sufficient time for the reading to stabilize on the digital display. The display will show the current pH value.
  4. Note any temperature readings if the electrode has an integrated temperature sensor and ATC (Automatic Temperature Compensation) is active.

6.2. Tahua Whakaterenga

The SET, ▼, and ▲ buttons are used to navigate through the device's menu options. Press SET to enter the menu or confirm a selection. Use ▼ and ▲ to scroll through options or adjust values.

  • SET (1): Enter/Exit menu, confirm selection.
  • ▼ (2): Scroll down, decrease value.
  • ▲ (3): Scroll up, increase value.

Specific menu functions (e.g., setting alarm limits, output configuration) will be detailed in a more advanced technical manual or on-screen prompts.

7. Tiaki

7.1. Cleaning the Converter

Wipe the exterior of the converter with a soft, damp kakahu. Kaua e whakamahi i nga kai horoi me nga whakarewa. Me whakarite kia kore he wai e uru ki te taputapu.

7.2. Te Tiaki Hiko pH

Proper maintenance of the pH electrode is crucial for accurate readings and extended lifespan. Refer to your specific pH electrode's instruction manual for detailed care instructions. General guidelines include:

  • Always keep the electrode's sensing bulb hydrated, typically in a storage solution or pH 7 buffer. Never store dry.
  • Rinse the electrode with distilled or deionized water after each measurement.
  • Clean the electrode regularly to remove sample residues. Specific cleaning solutions may be required depending on the application.
  • Recalibrate the electrode regularly, especially if readings become unstable or inaccurate.

7.3. Rokiroki

When not in use for extended periods, store the converter in a clean, dry environment at room temperature. Ensure the pH electrode is properly stored according to its manufacturer's recommendations.

8. Te Raru

Raruraru Take pea Rongoā
Kāore he whakaaturanga/Pūrere kāore e whakakā ana No power, faulty power supply, incorrect connection. Tirohia te taura hiko me te pūtake. Me whakarite kia tika te rōrahitage.
Unstable or inaccurate pH readings Electrode not calibrated, dirty electrode, damaged electrode, air bubbles, incorrect temperature compensation. Recalibrate electrode. Clean electrode. Replace electrode if damaged. Ensure electrode is fully submerged. Check ATC settings.
"Error" message on display Electrode fault, out of range measurement, internal device error. Check electrode connection. Try another electrode if available. Refer to specific error codes in a detailed technical manual. Contact support if persistent.
Te wa whakautu puhoi Aged or dirty electrode, low sample pāmahana. Clean or recondition electrode. Allow electrode to equilibrate with sample temperature. Consider replacing electrode.

If the problem persists after attempting these solutions, please contact Greisinger customer support or your local distributor.

9. Whakatakotoranga

Āhuahira Taipitopito
Kaihanga GREISINGER
Tauira Tuemi 602331
Rahi Hua (L x W x H) 5.5 x 8.2 x 8 cm; 9.07 karamu
ASIN B00ICKLET6
Te nui o nga taonga 1
Battery(ies) included Kao
Battery(ies) required Kao
Date first available on Amazon.com.be 12 Akuhata 2022
Discontinued by manufacturer Kao
Wāhanga e waatea ana Karekau he korero mo nga waahanga e manawapa ana

10. Pūtāhui me te Tautoko

Greisinger products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the warranty card included with your product or visit the official Greisinger webpae.

For technical support, troubleshooting assistance beyond this manual, or to inquire about spare parts and service, please contact your authorized Greisinger dealer or the manufacturer directly. Contact information can typically be found on the product packaging or the official Greisinger webpae.

Tuhinga e pa ana - GPHU 014 MP/BNC

Preview GREISINGER GE xxx Pukapuka Whakahaere: pH Hiko
He pukapuka mahi matawhānui mo nga irahiko pH raupapa GREISINGER GE xxx, e hipoki ana i te haumaru, i nga mea taketake, i te ine, i te whakatikatika, i te tiaki, i te kowhiringa me nga whakaritenga. Kei roto ko nga aratohu taipitopito mo te inenga pH tika.
Preview GREISINGER EBUW 232 EASYBUS Protocol Converter Operating Manual
Operating manual for the GREISINGER EBUW 232 EASYBUS protocol converter, detailing its specifications, general information, and safety requirements.
Preview GREISINGER GIA 20 EB / PK Manual: Hononga me te Mahi
Ko tenei pukapuka e whakarato ana i nga tohutohu matawhānui mo te GREISINGER GIA 20 EB / PK microprocessor-whakahaere whakaatu, aroturuki, me te taputapu whakahaere. Kei roto i nga ture haumaru, nga hononga hiko mo nga momo tohu whakauru me nga momo putanga, te whirihoranga taputapu ma te whakamahi i te rorohiko, te waahi whakawhiti me nga tautuhinga whakaoho, te whakarereketanga / whakaheke, te atanga rangatū, nga waehere hapa, nga whakaritenga, me nga tuhipoka tuku.
Preview GREISINGER GMH 3710 Tikanga Wehenga Tohu Whakahaere
Ko tenei pukapuka whakahaere e whakarato ana i nga tohutohu taipitopito mo te inemahana tika GREISINGER GMH 3710. Kei roto i te tikanga mo te whakamahi, te tiaki haumaru, te whakatakotoranga hua, te whakahaere, te whirihoranga, nga whiringa whakaputa, te whakatikatika whakauru, nga hononga tirotiro, nga maapono ine ine mahana, nga karere he, me nga aratohu tukunga mo nga pūoko pāmahana Pt100.
Preview Ngā Manometer me ngā Paemeter o te Greisinger GDH 200 Series: Hangarau Overview
Discover the Greisinger GDH 200 series handheld pressure measurement instruments. This document details the GDH 200-07 fine manometer, GDH 200-13 manometer, and GDH 200-14 vacuum/barometer, highlighting their specifications and features for professional use.
Preview Pukapuka Whakamahi mō te GREISINGER GMH 38-LW1 / -LW2 Mita Makuku Tāpiritanga
Operating manual appendix for the GREISINGER GMH 38-LW1 / -LW2 moisture measuring set for agricultural applications. Covers intended use, safety, product description, handling, principles of measurement, and specifications for wood chips, grain, hay, and straw.