1. Kupu Whakataki
The TENMARS TM-195 is a 3-axis high-frequency electromagnetic field strength meter designed for measuring and monitoring Radio Frequency (RF) electromagnetic fields. It is capable of measuring frequencies ranging from 50MHz to 3.5GHz. This manual provides essential information for the safe and effective operation of your device.
2. Nga korero haumaru
Please read and understand all safety instructions before operating the device.
- Kaua e ngana ki te whakatika, ki te whakarerekē rānei i te taputapu. Tukuna ngā mahi tiaki katoa ki ngā kaimahi whai tohu.
- Me whakarite kia kati pai te wāhanga pākahiko i te wā e whakamahia ana.
- A ape i te tuku i te taputapu ki te wera nui, te makuku, te ra tika ranei.
- Tiakina te taputapu mai i nga papa autō kaha.
- Whakakorehia nga pākahiko kia rite ki nga ture o te rohe.
3. Hua Neke Atuview
The TM-195 features a compact design with an integrated 3-axis isotropic sensor for comprehensive RF field strength measurements.

Whakaahua 1: TENMARS TM-195 RF Field Strength Meter and Carrying Case. The meter features an orange spherical sensor at the top, a green LCD display showing '360.4 mV/m' and '0945 XYZ', and control buttons below the display. A black carrying case is visible to the right.
3.1. Nga Taonga
- 3-Axis Isotropic Sensor: Spherical sensor for comprehensive field detection.
- Whakaaturanga LCD: 4-1/2 digits, maximum reading 19999, shows measured values, units, and status indicators.
- Patene Mana: For power, mode selection, unit change, data hold, alarm settings, and data memory.
- Wāhanga Pūhiko: Located at the rear for 9V battery.
3.2. Tohu Whakaatu
- XYZ: Indicates triaxial measurement mode.
- mV/m, V/m, µA/m, mA/m, µW/m², mW/m², µW/cm²: Waeine ine.
- MAX/AVG: Maximum and Average value indicators.
- Tohu: Data hold function active.
- PANUI: Alarm function active.
- Ata Pūhiko: E tohu ana i te taumata pākahiko.
4. Tatūnga
4.1. Tāuta Pūhiko
- Whakatuwheratia te uhi o te wahanga pākahiko kei muri o te taputapu.
- Insert a new 9V battery (NEDA 1604, IEC 6F22, or JIS 006P), observing polarity.
- Katia kia mau te uhi o te wahanga pākahiko.
4.2. Hia Tuatahi
Pehia te Mana button (labeled with a circle and vertical line) to turn on the device. The display will illuminate and show the current RF field strength.
5. Nga Tohutohu Whakahaere
5.1. Te Hiko / Whakaweto
- Hei whakakaha, pehia te Mana pātene.
- Ki te whakaweto, patohia kia mau te Mana te paatene mo te 2 hēkona.
5.2. Measurement Modes (MAX/AVG)
Pehia te MAX/AVG button to cycle through measurement display modes:
- Instantaneous Value: Displays the current real-time measurement.
- Maximum Value (MAX): Displays the highest value recorded since power-on or reset.
- Average Value (AVG): Displays the average value recorded over time.
- Maximum Average Value (MAX AVG): Displays the maximum of the averaged values.
5.3. Kohinga Unit
Pehia te UNIT/ENTER button to change the measurement unit. Available units include:
- mV/m (millivolts per meter)
- V/m (volts per meter)
- µA/m (microamperes per meter)
- mA/m (milliamperes per meter)
- µW/m² (microwatts per square meter)
- mW/m² (milliwatts per square meter)
- µW/cm² (microwatts per square centimeter)
5.4. Data Hold (HOLD/ALARM)
Pehia te HOLD/ALARM button briefly to freeze the current reading on the display. Press again to release.
5.5. Mahi Whakaoho
Hei tautuhi i te paepae whakaoho:
- Patohia me te pupuri i te HOLD/ALARM button for approximately 2 seconds to enter alarm setting mode.
- Whakamahia te MAX/AVG a REC/TIME buttons to adjust the threshold value.
- Perehi UNIT/ENTER ki te whakaū me te whakaora i te tautuhinga.
- The audible buzzer alarm will activate if the measured value exceeds the set threshold.
5.6. Data Memory (XYZ/MEM)
The device supports manual storage of up to 200 data sets.
- To save a reading, press the XYZ/MEM button briefly. The current reading will be stored.
- Hei maumahara i nga raraunga kua penapena, pehia me te pupuri i te XYZ/MEM button for approximately 2 seconds. Use the MAX/AVG a REC/TIME buttons to navigate through stored records.
- Perehi UNIT/ENTER to exit data recall mode.
5.7. Calibration Factor (CAL) Adjustment
The calibration factor can be adjusted if necessary. Refer to the SET button and its associated menu for this advanced setting. This feature allows for fine-tuning the meter's response.
5.8. Whakakorea te Aunoa
The device has an adjustable auto power-off function. The default time is 15 minutes. To adjust this setting:
- Patohia me te pupuri i te SET pātene ki te tomo i te tahua tautuhinga.
- Navigate to the auto power-off option using the MAX/AVG or REC/TIME pātene.
- Whakamahia te MAX/AVG a REC/TIME buttons to set the desired time (0 to 99 minutes).
- Perehi UNIT/ENTER to confirm and save. Setting to 0 disables auto power-off.
6. Tiaki
- Horoia te taputapu ki te kakahu ngohengohe, maroke. Kaua e whakamahi i nga kai horoi me nga whakarewa.
- Ki te kore e whakamahia te pūrere mō te wā roa, tangohia te pākahiko hei ārai i te turuturu.
- Whakaorangia te taputapu ki te waahi makariri, maroke, mawehe atu i te ra tika me te wera nui.
7. Te Raru
- Kaore te taputapu i te hiko: Tirohia te tāutanga o te pākahiko, kia tino mohio kei te rawaka te utu. Whakakapia mēnā e tika ana.
- Ngā pānui koretake: Ensure the device is held steady and away from large metallic objects or other strong RF sources that might interfere with measurements. Verify the selected unit is appropriate for the measurement range.
- Karekau te oro oro: Check if the alarm function is enabled and the threshold is set correctly.
- Kei te putea, kei te atarua ranei te whakaaturanga: Whakakapihia te pākahiko.
8. Whakatakotoranga
| Āhuahira | Whakatakotoranga |
|---|---|
| Awhe Auautanga | 50MHz ki te 3.5GHz |
| Whakaatu | Liquid-crystal (LCD), 4-1/2 digits, max reading 19999 |
| Momo Ine | Digital, Triaxial, Isotropic |
| Whakaatu Whakatau | 0.1mV/m, 0.1µA/m, 0.001µW/m², 0.001µW/cm² |
| Waeine | mV/m, V/m, µA/m, mA/m, µW/m², mW/m², µW/cm² |
| Whakaoho Rongo | Buzzer, adjustable threshold |
| Te Waa Whakatau | Typically 1.5s (0 to 90% measurement value) |
| Sample Reiti | 1.5 wa ia hekona |
| Mahara Raraunga | 200 data sets (manual) |
| Calibration Factor (CAL) | Ka taea te whakarite |
| Momo Pūhiko | 9V NEDA 1604, IEC 6F22 or JIS 006P |
| Ora Pūhiko | Tata ki te 15 haora |
| Whakaweto Aunoa | Default 15 minutes, adjustable 0~99 minutes |
| Te Waahi Mahi | 0°C ki +50°C (32°F ki te 122°F) |
| Te haumākū whakahaere | 25% ki te 75% RH |
| Paemahana Rokiroki | -10°C ki te +60°C (14°F ki te 140°F) |
| Rokiroki Haumākū | 0% ki te 80% RH |
| Ahu | 6.3 x 7.68 x 2.36 inihi (160 x 195 x 60 mm) |
| Taumaha | 0.44 Pounds (approx. 7 ounces / 200g) |
9. Pūtāhui me te Tautoko
For warranty information and technical support, please refer to the documentation provided with your purchase or contact TENMARS customer service. Keep your purchase receipt as proof of purchase.