COTEK SP-1000-224

Cotek SP-1000-224 Pure Sine Wave Inverter User Manual

Model: SP-1000-224 | Brand: COTEK

1. Kupu Whakataki

This manual provides detailed instructions for the installation, operation, and maintenance of the Cotek SP-1000-224 Pure Sine Wave Inverter. This inverter is designed to convert 24VDC power to 230VAC, providing a stable and reliable power source for various applications.

Āhuatanga matua:

  • Pure sine wave output for sensitive electronics.
  • Power ON / OFF remote control capability (Green Terminal).
  • Input & output fully isolated for enhanced safety.
  • Temperature & load controlled cooling fan for optimal performance.
  • Atanga ratarata-kaiwhakamahi.
  • Output frequency (50/60 Hz) selectable via DIP switch.
  • Putanga voltage selectable via DIP switch.
  • Power saving mode adjustable via variable resistor.
  • 3-color LED status indicators for easy monitoring.
  • Comprehensive input protection: Reverse Polarity (Fuse), Under Voltage, Neke Atu i te Voltage.
  • Robust output protection: Short Circuit, Overload, Over Temperature.
  • Type 1 Indoor Aluminum Enclosure.
  • E13 / UL / CE / FCC approved.

2. Nga korero haumaru

WARNING: Please read and understand all safety instructions before installing or operating this inverter. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.

  • Pūmate Hiko: This unit produces high voltage. Do not open the inverter casing. Tukuna atu nga ratonga katoa ki nga kaimahi whai tohu.
  • Haumaru Pūhiko: Work in a well-ventilated area. Batteries can produce explosive gases. Do not smoke or allow sparks or flames near the battery.
  • Whakahau Tika: Ensure adequate airflow around the inverter. Do not block ventilation openings.
  • Nga Tikanga Taiao: Do not expose the inverter to rain, moisture, or excessive dust. Operate in a dry, cool environment.
  • Whakapapa: The inverter must be properly grounded. Follow all local and national electrical codes.
  • Raukaha Uta: Do not exceed the inverter's rated power output. Overloading can cause damage to the inverter and connected devices.
  • California Proposition 65 Whakatupato: Tērā pea kei roto i tēnei hua ngā rauemi kua whakatūpatohia e te California Proposition 65.

3. Hua Neke Atuview me nga Waehanga

Familiarize yourself with the various parts of your Cotek SP-1000-224 Pure Sine Wave Inverter.

Cotek SP-1000-224 Pure Sine Wave Inverter, angled view

Whakaahua 3.1: Koki view of the Cotek SP-1000-224 Pure Sine Wave Inverter, showing its blue aluminum casing and grey end caps with ventilation and connection ports.

Front panel of Cotek SP-1000-224 Inverter with AC outlet and controls

Whakaahua 3.2: Front panel of the inverter, featuring the AC output socket (Schuko type), a power switch, LED indicators, and DIP switches for configuration.

Rear panel of Cotek SP-1000-224 Inverter with DC input terminals

Whakaahua 3.3: Rear panel of the inverter, showing the DC input terminals for battery connection, a remote control port (RJ45), and a green terminal block for remote ON/OFF control.

Te taha view of Cotek SP-1000-224 Inverter

Whakaahua 3.4: Te taha view of the inverter, highlighting its robust blue aluminum heat sink casing designed for efficient heat dissipation.

Cotek SP-1000 Series Inverter Features and Specifications Table

Whakaahua 3.5: A detailed table outlining the features and technical specifications of the Cotek SP-1000 series inverters, including input/output parameters, protections, and certifications.

Cotek SP-1000 Series Inverter Mechanical Drawings and Performance Curves

Whakaahua 3.6: Mechanical drawings providing dimensions of the inverter, along with power voltage and power temperature curves illustrating performance characteristics.

4. Tatūnga me te Tāuta

4.1 Te Kōwhiri i tētahi Wāhi:

  • Install the inverter in a dry, cool, and well-ventilated area.
  • Āraia te hihi tika o te rā, ngā pūtake wera, me te makuku.
  • Ensure sufficient clearance around the inverter for proper airflow, especially around the cooling fan and ventilation openings.
  • Mount the inverter securely on a stable, non-combustible surface.

4.2 DC Input Connection:

  1. Me whakarite kei te tūranga OFF te pana hiko o te inverter.
  2. Connect the positive (+) terminal of the 24VDC battery bank to the positive (+) DC input terminal on the inverter.
  3. Connect the negative (-) terminal of the 24VDC battery bank to the negative (-) DC input terminal on the inverter.
  4. Use appropriately sized cables to minimize voltage drop and ensure safe operation. Refer to electrical standards for cable sizing.
  5. Me whakarite kia piri, kia mau hoki nga hononga katoa.

4.3 AC Output Connection:

  • Plug your AC appliances directly into the AC output socket on the inverter.
  • Ensure the total power consumption of all connected appliances does not exceed the inverter's 1000W continuous output rating.

4.4 Whakapapa:

Proper grounding is essential for safety. Connect the inverter's chassis ground terminal to a reliable earth ground using a suitable grounding wire. Consult local electrical codes for specific grounding requirements.

4.5 Remote Control (Optional):

The inverter supports remote ON/OFF control via the green terminal block or an optional RJ45 remote control unit. Refer to the accessory manual for detailed instructions on connecting and using the remote control.

4.6 DIP Switch Configuration:

The inverter features DIP switches on the front panel to select output frequency (50/60 Hz) and output voltage. Refer to the table below for common settings. Ensure the inverter is OFF before changing DIP switch settings.

Ripanga 4.1: Example DIP Switch Settings (Consult Figure 3.5 for full details)
TautuhingaTUranga Whakawhiti DIP
Auautanga Putanga 50HzSwitch 1: OFF, Switch 2: OFF (Example, refer to actual product manual/Figure 3.5)
Auautanga Putanga 60HzSwitch 1: ON, Switch 2: OFF (Example, refer to actual product manual/Figure 3.5)
Putanga Voltage 230VACSwitch 3: ON, Switch 4: OFF (Example, refer to actual product manual/Figure 3.5)

Note: The exact DIP switch configurations for specific voltage and frequency settings are detailed in the product's full technical specifications (refer to Figure 3.5). Always verify settings before operation.

5. Mahi

5.1 Powering On the Inverter:

  1. Ensure all DC and AC connections are secure and correct.
  2. If using the remote control, ensure it is connected and in the ON position.
  3. Flip the main power switch on the inverter's front panel to the "ON" position.
  4. Observe the 3-color LED status indicators. A green light indicates normal operation.

5.2 LED Status Indicators:

  • Kākāriki: Mahi noa.
  • Kōwhai/Amipere: Warning (e.g., input voltage slightly low/high, minor overload). The inverter may continue to operate but requires attention.
  • Whero: Fault condition (e.g., severe overload, short circuit, over-temperature, critical input voltage). The inverter will shut down to protect itself and connected devices.

5.3 Power Saving Mode:

The inverter features a power saving mode, adjustable via a variable resistor. This mode reduces power consumption when no load or a very light load is detected. Adjust the resistor to set the sensitivity for entering/exiting power saving mode.

5.4 Powering Off the Inverter:

  1. Turn off all connected AC appliances.
  2. Flip the main power switch on the inverter's front panel to the "OFF" position.
  3. If using a remote control, turn it off as well.

6. Tiaki

Regular maintenance ensures the longevity and reliable operation of your inverter.

  • Te horoi: Horoia te taha waho o te inverter i ia wā ki te kakahu maroke, ngohengohe. Kaua e whakamahi i ngā wai horoi, i ngā whakarewa rānei. Kia kore he puehu, he paru rānei i roto i ngā pūaha hauhautanga.
  • Hononga: Periodically check all DC and AC connections to ensure they are tight and free from corrosion. Loose connections can cause overheating and poor performance.
  • Whakahau: Ensure the cooling fan and ventilation grilles are not obstructed. The fan operates based on temperature and load, so ensure it can draw and expel air freely.
  • Hauora Pūhiko: Monitor the health of your battery bank. A weak or failing battery can negatively impact inverter performance and lifespan.

WARNING: Do not attempt to service the inverter yourself. There are no user-serviceable parts inside. Refer all servicing to qualified personnel.

7. Te Raru

This section provides solutions to common issues you might encounter with your inverter. If the problem persists after following these steps, contact customer support.

RaruraruTake peaRongoā
Inverter does not turn on (No LED indication)
  • Nga hononga DC wetekina
  • Blown DC input fuse
  • Pūhiko voltage iti rawa
  • Whakawhiti Whakawhiti
  • Check and tighten DC cables.
  • Tirohia me te whakakapi i te fiusi mēnā e tika ana (kia tika te whakatauranga).
  • Charge battery or check battery health.
  • Ensure inverter switch is ON.
Red LED is on, inverter shuts down
  • Te taumahatanga
  • Iahiko poto i te putanga AC
  • Te werawera
  • Whakauru i runga/i raro voltage
  • Whakaitihia te kawenga hono.
  • Check AC wiring for shorts.
  • Tukua te inverter kia whakamatao; whakarite kia tika te hau.
  • Tirohia te puhiko voltage; ensure it's within operating range.
Yellow/Amber LED is on
  • Minor overload
  • Whakauru voltage near limits
  • Whakaitihia te kawenga ki te taea.
  • Aroturuki pūhiko voltage; ensure it's stable.
Kaore he putanga AC
  • Kāore te inverter i te whakakāhia
  • Fault condition (Red LED)
  • AC appliance issue
  • Check power switch and LED status.
  • Refer to "Red LED is on" solutions.
  • Test AC appliance with another power source.

8. Whakatakotoranga Hangarau

The following table provides detailed technical specifications for the Cotek SP-1000-224 Pure Sine Wave Inverter. For a comprehensive overview, refer to Figure 3.5.

TawhāValue (SP-1000-224)
TauiraSP-1000-224
AC Putanga Voltage230VAC (selectable)
DC Whakauru Voltage24VDC
Te Mana Tonu1000W
Surge Power (3 sec)1750VA
Puka Ngaru HuaputaNgaru Hine Tino (THD <3%)
Auautanga Putanga50/60 Hz (ka taea te whiriwhiri)
Kakama (Max)92%
Whakauru i raro i te Voltage Tiaki21.0 ± 0.5VDC
Tāuru Neke Voltage Tiaki33.0 ± 0.5VDC
Te Waahi Mahi-20°C ~ +40°C (60% power load)
Ahu (L x W x H)17 x 10 x 6 inihi (hua)
Taumaha8.94 pauna
TiwhiketeE13 / UL / CE / FCC whakaaetia

Note: Specifications are subject to change without notice. Always refer to the product label or manufacturer's official documentation for the most accurate and up-to-date information.

9. Nga Korero Whakaputanga

COTEK products are manufactured to high quality standards. For specific warranty terms and conditions, including duration and coverage, please refer to the warranty card included with your product or visit the official COTEK webpae. Puritia to tohu hoko mo nga kereme whakamana.

Typical warranties cover defects in materials and workmanship under normal use. Damage caused by improper installation, misuse, abuse, or unauthorized modifications is generally not covered.

10. Tautoko Kiritaki

If you have any questions, require technical assistance, or need to report an issue with your Cotek SP-1000-224 Pure Sine Wave Inverter, please contact COTEK customer support or your authorized dealer.

Ina whakapā atu ki te tautoko, kia rite nga korero e whai ake nei:

  • Product Model: SP-1000-224
  • Serial Number (if applicable, usually found on the product label)
  • Te Ra o te Hokonga
  • He whakamārama taipitopito mō te raruraru e pāngia ana koe.

For the most up-to-date contact information, please visit the official COTEK webpae: www.cotek.com.tw (He kaipupuri waahi tenei URL, tēnā manatokohia te kaihanga tuturu webpae).

Tuhinga e pa ana - SP-1000-224

Preview COTEK SP Series Pure Sine Wave Inverter Manual's User's User
Te pukapuka a te kaiwhakamahi mo te COTEK SP Series Pure Sine Wave Inverters (SP-700 ki SP-4000). Ako mo te whakaurunga, te mahi, te haumaru, nga whakaritenga hangarau, me nga ahuatanga matatau penei i te putanga ngaru ngaru parakore me te whakamarumaru pakari.
Preview COTEK SP Series Pure Sine Wave Inverter Manual's User's User
Comprehensive user's manual for COTEK SP Series Pure Sine Wave Inverters (SP-700, SP-1000, SP-1500, SP-2000, SP-3000, SP-4000). Covers specifications, installation, operation, safety, and RS-232 communication for reliable power conversion.
Preview Pukapuka Kaiwhakamahi mō te Hurihuri Ngaru Parakore COTEK SK Series 1500W
He pukapuka ā-ringa whānui mō te COTEK SK Series 1500W Pure Sine Wave Inverter, e kapi ana i te haumaru, ngā āhuatanga, ngā whakaritenga, te tāutanga, te whakahaere, te tiaki, me te rapurongoā. E whakarato ana i ngā aratohu taipitopito mō te whakamahinga tika me te tiaki.
Preview COTEK SR-1600 PLUS Rack Mount Pure Sine Wave Inverter: Quick Introduction
He potoview of the COTEK SR-1600 PLUS series rack-mount pure sine wave inverters, detailing specifications, product appearance, installation, and warranty information.
Preview COTEK SR-1600 PLUS Pure Sine Wave Inverter User Manual
Comprehensive user manual for the COTEK SR-1600 PLUS Pure Sine Wave Inverter, covering safety instructions, functional characteristics, electrical specifications, installation, maintenance, troubleshooting, and warranty information.
Preview Rangatū COTEK SPT He Mahinga Ngaru Hine Pure Inverter Manual - SPT1200/2000/3000
He pukapuka whakamahi matawhānui mo nga Hurihuri Ngaru Wai Maamaa COTEK SPT Series (SPT1200, SPT2000, SPT3000). Ka hipoki i nga tohutohu haumaru, nga ahuatanga mahi, nga whakaritenga, te whakaurunga, te tiaki, te korero RS-485, te rapu raruraru, me nga korero whakamana.