The Dickson C662 Chart is a specialized replacement chart designed for use with compatible circular chart recorders. This 6-inch diameter chart is calibrated for 24-hour recording cycles and features a measurement range of 0 to +500 units, making it suitable for various industrial and scientific data logging applications. It serves as a consumable component essential for accurate and continuous data visualization.

Dickson C662 6-inch circular chart with grid lines and numerical scales.

Figure 1: Dickson C662 6-inch circular chart. This image displays the Dickson C662 circular chart, designed for 24-hour recording. The chart features a detailed grid with radial and concentric lines, indicating time and measurement values. The center of the chart includes the 'DICKSON' brand name and model information. The outer edge is marked with time increments, and the inner area shows measurement scales ranging from 0 to +500.

Tatūnga me te Tāuta

Proper installation of the Dickson C662 chart is crucial for accurate data recording. Follow these steps to replace or install a new chart in your compatible circular chart recorder:

  1. Weto Whakakore: Before handling the chart recorder, ensure the device is powered off or disconnected from its power source to prevent accidental operation or damage.
  2. Open Recorder: Carefully open the chart recorder's cover or access panel to expose the chart mounting mechanism.
  3. Remove Old Chart (if applicable): If replacing an existing chart, gently lift the pen arm(s) away from the chart surface and remove the used chart from the center hub. Dispose of the used chart responsibly.
  4. Align New Chart: Take a new Dickson C662 chart. Locate the center hole and align it with the chart recorder's center hub. Ensure the chart lies flat and is properly seated.
  5. Tautuhi Wā/Rā: Rotate the chart until the current time and date on the chart align with the recorder's time indicator or pen position. This ensures accurate time-based recording.
  6. Lower Pen Arm(s): Carefully lower the pen arm(s) back onto the chart surface. Ensure the pen tip makes proper contact without excessive pressure.
  7. Close Recorder: Securely close the chart recorder's cover or access panel.
  8. Whakahiko: Reconnect power to the chart recorder and verify that the chart is rotating correctly and the pen(s) are marking as expected.

Note: Always refer to your specific chart recorder's manual for detailed installation instructions, as procedures may vary slightly between models.

Nga Aratohu Mahi

Once installed, the Dickson C662 chart operates in conjunction with your chart recorder to provide a visual record of measured parameters. To ensure optimal performance and accurate data capture:

Te tiaki me te rokiroki

Proper handling and storage of Dickson C662 charts will preserve their quality and ensure readiness for use:

Raparongoā

While the Dickson C662 chart is a passive component, issues related to its interaction with the recorder can occur. Consider the following if you encounter problems:

Whakatakotoranga

HuangaTaipitopito
Tau tauiraC662
WaitohuDickson
Diamita Tūtohi6 inihi
Wā Rekoata24 haora
Awhe Ine0 ki te +500
Ahu mōkihi3.94 x 3.94 x 3.94 inihi
Taumaha Tūemi10.56 hekere
KaihangaThomas Scientific
ASINB00VGDSFDO
Te Ra Tuatahi WāteaMaehe 31, 2015

Pūtāhui me te Tautoko

As the Dickson C662 Chart is a consumable item, specific warranty information typically applies to the chart recorder itself rather than the individual charts. For details regarding product warranty, returns, or technical support, please refer to the documentation provided with your chart recorder or contact the manufacturer of the chart recorder directly.

For inquiries related to the Dickson C662 charts, please contact your supplier or the manufacturer, Thomas Scientific, for assistance.

Tuhinga e pa ana - C662

Preview Dickson KT8 Series Temperature Recorders: Pukapuka Kaiwhakamahi me te Aratohu Timata Tere
Aratohu matawhānui mō Dickson KT8P, KT8P2, KT8P3, me te raupapa KT856 raupapa whakamaarama whakamaarama. Ka hipokina te tatūnga, te mahi, te whakaohooho, te whakahuri ruku, te whakatikatika, te rapu raruraru, me nga korero whakamana.
Preview DICKSON Tukanga Logger HT350: Aratohu Kaiwhakamahi me te Tatūnga
He aratohu matawhānui ki te whakarite, te whakamahi, me te rapurongoā i te DICKSON Process Logger HT350, tae atu ki te whakaurunga rorohiko, te takiuru raraunga, me nga korero whakamana.
Preview Pukapuka Kaiwhakamahi me te Aratohu Hua mō te Rekoata Tūtohi Pene Kotahi me te Pene Rua a Dickson 8"
Kei roto i tēnei pukapuka kaiwhakamahi me te aratohu hua ngā tohutohu taipitopito mō te whakahaere me te whirihora i ngā Pūreretuhi Tūtohi Dickson 8" One and Two Pen, tae atu ki te tatūnga, ngā kōwhiringa tahua, ngā waehere hapa, me ngā whakatakotoranga tauira.
Preview Akoranga Whakangungu ThermoServer / ThermoClient Kua Otiview | TIKIHANA
Ka mutu nga koreroview o te akoranga whakangungu DICKSON ThermoServer / ThermoClient, e kapi ana i te hoahoanga pūnaha, te taputapu, te pūmanawa, te tiaki, te rapurongoā, me ngā whāinga ako. He pai mō ngā kaiwhakamahi me ngā kaiwhakahaere hou.
Preview Dickson DSB USB Display Logger Quick Start Guide
Quick start guide for the Dickson DSB USB Display Logger, covering setup, configuration using DicksonWare, data downloading methods, and replaceable sensors.
Preview Dickson ES120/ES120A Electronic Signal Data Logger - Manual & Specifications
Comprehensive guide for the Dickson ES120 and ES120A Electronic Signal Data Loggers, covering product applications, specifications, operating instructions, software, FAQs, and warranty.