This instruction manual provides essential information for the proper installation, operation, and maintenance of the Master-Bilt 19-00816 Timer Unit on Bracket. This unit is designed for use in commercial refrigeration systems, specifically as a freezer part, to control operational cycles. Adherence to these instructions will ensure optimal performance and longevity of the timer unit.

2. Hua Neke Atuview

The Master-Bilt 19-00816 is a timer unit pre-mounted on a bracket, facilitating easier installation into compatible refrigeration systems. It features a mechanical timer dial for setting operational schedules and includes necessary electrical connections for integration.

Master-Bilt 19-00816 Timer Unit on Bracket, overall view

Whakaahua 2.1: Te nuinga view of the Master-Bilt 19-00816 Timer Unit on Bracket. This image displays the complete assembly, including the green circuit board, the central timer dial, relays, and the grey mounting bracket.

Te taha view of Master-Bilt 19-00816 Timer Unit showing electrical components

Whakaahua 2.2: Te taha view of the timer unit, illustrating the various electrical components such as relays and capacitors mounted on the circuit board, along with some terminal connections.

3. Nga korero haumaru

4. Tatūnga me te Tāuta

This section outlines the general steps for installing the timer unit. Specific wiring diagrams for your refrigeration system should be consulted.

  1. Momotu Hiko: Turn off and lock out the main power supply to the refrigeration unit. Confirm power is off using a voltage Kaiwhakamatautau.
  2. Whakapiki: Secure the timer unit's bracket to a stable surface within the refrigeration system's control panel using appropriate fasteners. Ensure the unit is mounted in an orientation that allows for easy access to the timer dial and wiring terminals.
  3. Hononga Waea:
    • Identify the appropriate wiring terminals on the timer unit and the corresponding wires from the refrigeration system.
    • Connect the power input, load output, and any control wires as per the refrigeration system's wiring diagram. Ensure all connections are secure and properly insulated.
    • Refer to the labels on the circuit board (e.g., F, 3, 1, 2, 4, N) for terminal identification.
    Master-Bilt 19-00816 Timer Unit showing wiring terminals

    Whakaahua 4.1: View of the timer unit highlighting the electrical terminal blocks. This image shows the screw terminals where system wiring connects to the timer unit for power and load control, with labels like F, 3, 1, 2, 4, N visible.

  4. Hinga-Whakaoho tuatahi: Once all connections are verified, restore power to the refrigeration system. Observe the timer unit for proper operation and any error indicators.

5. Mahi

The Master-Bilt 19-00816 Timer Unit utilizes a mechanical dial for setting operational cycles, typically for defrost or other timed functions within a refrigeration system.

  1. Tautuhi i te wa o te ra: Rotate the outer dial of the timer until the current time aligns with the indicator arrow or mark on the timer's stationary housing.
  2. Setting ON/OFF Cycles: The timer dial features small pins or segments around its circumference.
    • To set an "ON" period, push the corresponding pins/segments inwards.
    • To set an "OFF" period, leave the corresponding pins/segments outwards.
    • Each segment typically represents a specific time interval (e.g., 15 minutes). Consult the timer's markings for precise intervals.
  3. Whakakore a-ringa (mehemea e tika ana): Some timers may include a manual override switch or lever. Refer to the timer unit itself for any such feature and its operation.
runga-iho view of Master-Bilt 19-00816 Timer Unit dial for setting cycles

Whakaahua 5.1: Taipitopito runga-iho view of the mechanical timer dial, showing the numbered segments and the central arrow indicator used for setting the time of day and programming ON/OFF cycles.

6. Tiaki

Regular maintenance ensures the reliable operation of your timer unit.

7. Te Raru

Kei roto i tēnei wāhanga he aratohu mō ngā take noa. Mō ngā raruraru uaua, whakapā atu ki tētahi tohunga hangarau whai tohu.

RaruraruTake peaRongoā
Timer unit not operating (no movement, no output).Kāore he pūtake hiko; he hē te waea; he hapa te waeine.
  • Verify power supply to the unit.
  • Check all wiring connections against the system diagram.
  • If power and wiring are correct, the unit may be faulty and require replacement.
Load (e.g., defrost heater) not turning ON/OFF as scheduled.Incorrect timer settings; faulty relay; load issue.
  • Re-check the ON/OFF pin settings on the timer dial.
  • Ensure the time of day is correctly set.
  • Inspect the load (e.g., defrost heater) for functionality.
  • A faulty internal relay may require unit replacement.
Timer dial not advancing.No power to the timer motor; mechanical obstruction; faulty motor.
  • Verify continuous power supply to the timer unit.
  • Check for any physical obstructions preventing dial movement.
  • If power is present and no obstruction, the internal motor may be faulty, requiring unit replacement.

8. Whakatakotoranga

Tau tauiraMB19-00816
WaitohuMaster-Bilt
Hunga Hua7"D x 9"W x 7"H (approximate, based on package dimensions and product description)
Taumaha Tūemi1.01 Pauna (0.46 kg)
Whenua TaketakeUnited States
UPC046843109531, 220215087423

9. Pūtāhui me te Tautoko

Specific warranty information for the Master-Bilt 19-00816 Timer Unit on Bracket is not provided in the product details. Please refer to the original purchase documentation or contact Master-Bilt customer service for warranty details and technical support.

For further assistance, please visit the official Master-Bilt website or consult your authorized Master-Bilt dealer.

Tuhinga e pa ana - MB19-00816

Preview Nga Hua Whakamao-Bilt Refrigeration: Nga Tikanga Tika - Aratohu Hua
Tūhurahia te whānuitanga matawhānui a Master-Bilt o nga rongoā whakamatao arumoni, tae atu ki nga kaihokohoko whakaatu, nga whakamahana hiko me nga pouaka pouaka, me nga punaha whakamatao matatau. Ko tenei aratohu e whakarato ana i nga meka hua me nga whakaritenga.
Preview Ngā Pūnaha Whakamatao Mamao Master-Bilt Split-Pak A2L: Ngā Āhuatanga, Ngā Whakatakotoranga, me Ngā Aratohu Tauira
Explore the Master-Bilt Split-Pak A2L™ Remote Refrigeration Systems, engineered for efficiency, easy setup, and performance in high-temperature environments. This document details condensing units, evaporator coils, LogiTemp electronic controller systems, and model number guides.
Preview Master-Bilt BEL/BEM-CU Series Installation and Operations Manual
Comprehensive guide for installing, operating, and servicing Master-Bilt BEL/BEM-CU Series commercial refrigeration display cases. Includes safety instructions, parts lists, and troubleshooting.
Preview Te Whakamatao Pae Whakamuri Master-Bilt: Aratohu Tāutanga, Whakahaere, me te Tiaki
Comprehensive guide for installing, operating, and maintaining Master-Bilt Back Bar Refrigeration units (BB Series). Includes inspection, installation steps, operation details, maintenance procedures, troubleshooting tips, detailed specifications, and parts lists for both Glass Door and Solid Door models BB59, BB59G, BB69, BB69G, BB79, BB79G, BB95, BB95G.
Preview Kaiwhakaako-Bilt COLDIN-3 Rangatū Whakaaturanga Whakatio: Te Tautau me te Mahinga Mahi
He pukapuka whakaurunga me nga mahi mo te Kaiwhakaako-Bilt COLDIN-3 Series MSC-A me MSF-A tauira pouaka pouaka whakaata. Ka hipokina te kawe, te whakaurunga, te mahi, te rokiroki, te whakaheke hukapapa, te tiaki, te rapu raruraru, me nga aratohu haumaru.
Preview Kaiwhakaako-Bilt IM-23GB Kaihoko Tio: Te Whakaurunga me nga Mahi Mahi
Ko tenei pukapuka matawhānui e arahi ana i nga kaiwhakamahi i roto i te whakaurunga, te mahi, me te mahi i te Kaiwhakaako Ice Master-Bilt IM-23GB, me te TLY 25 Controller. Ka kapi te haumaru, te mahi, te tiaki, te rapu raru, me nga waahanga.