DAB 60161182

Pukapuka Kaiwhakamahi mō te Pūnaha Whakarei Wai DAB E.SYBOX 230V

Tauira: 60161182

1. Kupu Whakataki

The DAB E.SYBOX is an integrated electronic water booster system designed for domestic and residential applications. This system provides constant water pressure while optimizing energy consumption. It is suitable for use with potable water in domestic plants, for gardening, and irrigation. The E.SYBOX can also be used to create groups of up to four pumps.

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your E.SYBOX system. Please read it thoroughly before installation and keep it for future reference.

2. Nga korero haumaru

WARNING: Before performing any operation on the pump, disconnect it from the main power supply.

  • Whakaritehia te voltage matches the specifications of the E.SYBOX (230V).
  • Ko te whakaurunga me te tiaki me mahi ma nga kaimahi mohio anake.
  • Do not operate the pump with flammable or explosive liquids.
  • Whakaorangia te waeine mai i te wera mīti.
  • Me whakarite kia tika te hau huri noa i te waahanga kia kore ai e wera rawa.
  • Me tika te whakatuu whenua.

3. Ihirangi mokete

Manatokohia kei te noho katoa nga waahanga me te kore e pakaru i te wa e wetewete ana:

  • DAB E.SYBOX Water Booster System Unit
  • Waea hiko
  • Connection Pieces (e.g., 1" plastic unions)
  • Pukapuka Kaiwhakamahi (tenei tuhinga)

4. Tatūnga me te Tāuta

The E.SYBOX is designed for straightforward installation and requires no additional components for basic setup. It can be installed either vertically or horizontally.

4.1. Te Kōwhiri i tētahi Wāhi Tāutanga

Tīpakohia he tauwāhi ko:

  • Protected from direct sunlight and extreme temperatures.
  • In a closed space without a high level of air exchange, as the unit is water-cooled and quiet.
  • He waatea mo te tiaki.
  • Near the water source and the distribution system.

4.2. Tāutanga Tinana

  1. Te Whakanoho i te Waeine: Place the E.SYBOX on a stable, level surface. The anti-vibration feet help reduce noise. The unit can be positioned vertically or horizontally.
  2. DAB E.SYBOX Water Booster System, front view

    Whakaahua 1: Mua view of the DAB E.SYBOX unit, showing the display and general form factor.

  3. Te Hononga i ngā Paipa Wai: Connect the inlet pipe from your water source to the suction port and the outlet pipe to your distribution system. Use the provided 1" plastic unions for secure connections. Ensure all connections are watertight.
  4. DAB E.SYBOX Water Booster System, rear view me nga hononga

    Whakaahua 2: Whakamuri view of the E.SYBOX, highlighting the water inlet and outlet connections.

  5. Hononga Hiko: Connect the power cord to a grounded 230V AC outlet. Ensure the power supply is stable and protected from surges.
  6. Priming the Pump (if necessary): For initial startup or after maintenance, ensure the pump is filled with water before operation to prevent dry running. Refer to the display for priming instructions.

5. Nga Tohutohu Whakahaere

The E.SYBOX features an adjustable, high-resolution LCD display for easy operation and monitoring.

5.1. Te Hia-Ai Tuatahi

  1. Once connected to power, the LCD display will illuminate.
  2. Follow the on-screen prompts for initial setup, which may include language selection and basic pressure settings.

5.2. Setting Desired Pressure

The E.SYBOX allows you to set your desired water pressure. The system will then maintain this constant pressure by adjusting pump speed.

  • Navigate through the LCD menu using the control buttons adjacent to the display.
  • Locate the "Pressure Setting" option.
  • Adjust the pressure value (e.g., in PSI or Bar) to your preference. The system can deliver up to 210 ft (approx. 90 PSI) of head.
  • Confirm your selection. The system will automatically adjust to maintain this pressure.
DAB E.SYBOX Water Booster System with power and flow specifications

Figure 3: E.SYBOX display showing operational parameters such as power consumption (360W), pressure (3 Bar / 43 PSI), and flow rate (3.2 GPM / 12 l/min).

5.3. Aroturuki Mahinga

The LCD display provides real-time statistics:

  • Pēhanga: Current system pressure.
  • Rere Rere: Instantaneous water flow.
  • Whakamahi Hiko: Energy consumption of the unit.
  • Whakaoho/Whakatupato: Notifications for any operational issues.

6. Tiaki

Regular maintenance ensures the longevity and optimal performance of your E.SYBOX system.

6.1. Nga Tirohanga Mahi

  • Tirotiro Ataata: Periodically check for any leaks, unusual noises, or visible damage.
  • Air Exchange: Ensure the area around the unit is not obstructed to allow for proper air circulation for the water-cooled motor.

6.2. Pūoko Cleaning

Over time, sediment may accumulate and affect the flow sensors. The E.SYBOX comes with a tool for cleaning these sensors.

  1. Momotu Mana: Always disconnect the unit from the power supply before any maintenance.
  2. Locate Sensors: Refer to the detailed diagram in the full technical manual (if available) to locate the flow sensors.
  3. Ma: Use the provided tool to carefully clean any accumulated sediment from the sensors.
  4. Whakahono ano: Reassemble any removed parts and reconnect power.

6.3. Ko te takurua

If the unit is installed in an area subject to freezing temperatures, it must be drained to prevent damage.

  • Momotuhia te mana.
  • Drain all water from the pump and associated piping.
  • Store in a frost-free environment if possible, or ensure complete drainage.

7. Te Raru

This section addresses common issues you might encounter with your E.SYBOX system.

RaruraruTake peaRongoā
No water flow / Pump not startingNo power; Air in pump; Clogged inlet; Low water level in source.Check power connection; Prime the pump; Clean inlet filter; Ensure adequate water supply.
Te pehanga itiIncorrect pressure setting; Partially clogged filter/pipes; Air in system.Adjust pressure setting on LCD; Inspect and clean filters/pipes; Bleed air from system.
Pump runs continuously / Frequent on/off cyclingLeak in system; Small continuous flow (e.g., dripping faucet); Faulty sensor.Check for leaks in plumbing; Address small continuous flows; Contact support if sensor is suspected.
Haruru rerekee, wiri raneiAir in pump; Loose connections; Foreign object in pump.Prime the pump; Check and tighten all connections; Disconnect power and inspect pump impeller (if safe and accessible).
LCD display error messageHe hapa punaha motuhake.Note the error code and consult the full technical manual or contact customer support.

Mena kei te haere tonu te raru i muri i te whakamatau i enei otinga, tena koa whakapā atu ki te tautoko a te kaihoko.

8. Whakatakotoranga

ĀhuahiraTaipitopito
Tauira60161182
Voltage230 Volts
Puna ManaAC/DC
Rere Rere Morahi32 Karani mo ia meneti (GPM)
Teitei Whakaara Mōrahi (Upoko)210 Puawai
Awhe Temperature Wai+32 to +95°F (domestic use), +32 to +102°F (other uses)
Te Hohonu Momo Momorahi26 Puawai
Taumaha Tūemi57 Pauna
Rahi Hua (L x W x H)14.25 x 10.35 x 22.2 inihi
RauemiABS
Integrated Expansion Tank0.5 Karani

9. Pūtāhui me te Tautoko

9.1. Nga Korero Whakaputanga

DAB provides a limited warranty for the E.SYBOX 230V Water Booster System against defects in materials and workmanship under normal use and service. The specific duration and terms of the warranty may vary by region and purchase date. Please retain your proof of purchase for warranty claims.

For detailed warranty terms and conditions, refer to the warranty card included with your product or visit the official DAB webpae.

9.2. Tautoko Kiritaki

If you require technical assistance, have questions about installation, operation, or maintenance, or need to report a problem, please contact DAB customer support.

  • Tautoko Aipurangi: Visit the official DAB Pumps website for FAQs, technical documents, and contact forms.
  • Tautoko Waea: Refer to the contact information provided on the DAB webte pae tukutuku, te takai hua rānei mō ngā nama tautoko ā-rohe.
  • When contacting support, please have your product model (60161182) and serial number (if applicable) ready.

Tuhinga e pa ana - 60161182

Preview DAB Esybox Mini 3 Quick Installation Guide
A concise guide for the quick installation of the DAB Esybox Mini 3 variable speed booster pump, covering setup, connections, and initial operation.
Preview Esybox Mini³: Manuale di Installazione e Manutenzione
Guida completa all'installazione, configurazione e manutenzione del sistema di pompaggio Esybox Mini³ di DAB Water Technology.
Preview DAB Esybox Pop Systema Elettronico i Pressurizzazione - Dati Tecnici and Funzionalità
Nga korero korerotagE pa ana ki te DAB Esybox Pop, me te punaha hiko mo te hunga noho, me whakauru atu ki nga hangarau motuhake, ki nga tohu o mua, ki nga ratonga mamati H₂D me nga taputapu.
Preview He Aratohu Tīmatanga Tere mō te Papu Ruku Maroke DAB Pulsar
He aratohu poto mō te tāuta me te whakahaere i te papu ruku DAB Pulsar Dry, tae atu ki ngā whakatakotoranga hangarau, ngā whakatūpato haumaru, me ngā taipitopito hononga.
Preview DAB E.SYTANK: Te Hangarau o te Tāke Rokiroki Wai Inuview
Tūhurahia te DAB E.SYTANK, he tāke rokiroki wai inu i hangaia mō te tuku wai whai hua i roto i ngā whare noho me ngā tono arumoni māmā, he maha ngā wā ka whakauruhia ki te pūnaha papu whakanui E.SYBOX.
Preview DAB Digital Radio Receiver Mana me Tautuhinga
He aratohu ki nga mana me nga tautuhinga o te kaikawe reo irirangi mamati DAB, tae atu ki te kowhiringa teihana, nga rarangi hongere, nga mahi rapu, me nga manakohanga punaha.