1. Kupu Whakataki

The OWON XSA1015-TG is a high-performance spectrum analyzer designed for precise measurement and analysis of electrical signals. This instrument features a 10.4-inch TFT LCD touch screen, a frequency range from 9 kHz to 1.5 GHz, and an integrated tracking generator. It is suitable for various applications including signal distortion analysis, modulation analysis, spectral purity assessment, and EMI pre-compliance testing. This manual provides essential information for the safe and efficient operation of your device.

Key features of the XSA1015-TG include:

  • Awhe Auautanga: 9 kHz ki te 1.5 GHz
  • Displayed Average Noise Level (DANL): -150 dBm
  • Phase Noise: -85 dBc/Hz @1 GHz and 10 KHz offset
  • Tapeke Amplitude Accuracy: <1.5 dB
  • Minimum Resolution Bandwidth (RBW): 10 Hz
  • Integrated 1.5 GHz Tracking Generator
  • 10.4-inch TFT LCD Display for clear visualization
OWON XSA1015-TG Spectrum Analyzer front view with 150dBm Displayed Average Noise Level text overlay

Whakaahua 1: Mua view of the OWON XSA1015-TG Spectrum Analyzer, highlighting its display and control panel.

2. Tatūnga

2.1 Te Wetewete me te Tirotiro

Carefully remove the spectrum analyzer from its packaging. Inspect the device for any signs of physical damage that may have occurred during transit. Retain the packaging materials for future transportation or storage.

2.2 Hononga Hiko

Connect the provided power cord to the AC input on the rear panel of the device. Ensure the power source meets the specified requirements: 100V - 240V AC, 50/60Hz. The power input is located on the rear of the unit, typically near the fuse holder.

Whakamuri me te taha view of the OWON XSA1015-TG Spectrum Analyzer, showing power input and ventilation

Whakaahua 2: Whakamuri me te taha views of the spectrum analyzer, illustrating the power input and ventilation.

2.3 Connecting RF Input and Tracking Generator Output

The front panel features the RF Input and Tracking Generator Output connectors. Both are N-type female connectors with a 50 Ω impedance.

  • Tāuru RF: Connect the signal to be analyzed to the RF Input connector. Observe the maximum safe reverse level of +30 dBm / 50 VDC.
  • Tracking Generator Output: Use this connector to output a tracking signal for characterization of devices under test. The maximum safe reverse level is +20 dBm / 50 VDC.
Close-up of the front panel connectors on the OWON XSA1015-TG, showing RF Input and GEN Output

Whakaatu 3: Taipitopito view of the RF Input and Tracking Generator Output connectors on the front panel.

2.4 Tauranga Whakawhitiwhiti

The rear panel provides various communication ports for external connectivity:

  • Kaihautū USB: For connecting USB storage devices to save data.
  • USB DEVICE: For connecting the analyzer to a computer.
  • LAN: For network connectivity and remote control.
  • VGA: Hei hono i tētahi mata o waho.
  • Tauranga Waeaoro: Mo te putanga ororongo.
  • 10 M Reference Input: 50 Ω, N-type female connector for an external 10 MHz reference clock.
Whakamuri view of the OWON XSA1015-TG Spectrum Analyzer, showing various communication ports

Figure 4: Rear panel of the spectrum analyzer, displaying the communication and reference input ports.

3. Nga Tohutohu Whakahaere

3.1 Powering On and Basic Interface

Press the 'On/Off' button on the front panel to power on the device. The 10.4-inch TFT LCD will display the main measurement interface. The interface is designed with clear color, size, and shape distinctions for buttons and function areas, facilitating quick adjustments.

3.2 Setting Frequency Parameters

To set the frequency range for your measurement:

  1. Pehia te FREQ pātene i runga i te paewhiri mana.
  2. Use the soft keys on the display or the numeric keypad to enter values for:
    • Center Freq: Sets the center frequency of the displayed span.
    • Start Freq: Sets the lowest frequency of the displayed span.
    • Stop Freq: Sets the highest frequency of the displayed span.
    • Awheawhe: Sets the frequency range displayed on the screen.
  3. Adjust the Resolution Bandwidth (RBW) by pressing the BW button and selecting the desired value. The minimum RBW is 10 Hz.
OWON XSA1015-TG Spectrum Analyzer display showing a signal trace and measurement settings

Figure 5: The spectrum analyzer display showing a typical signal measurement with frequency and amptautuhinga reo.

3.3 Tautuhinga Amplitude Parameters

To control the vertical scale of the display:

  1. Pehia te AMPTD pātene.
  2. Whakaritea te Taumata Tohutoro to set the top line of the display in dBm.
  3. Whakaritea te Te whakaheke to prevent input overload and optimize the signal-to-noise ratio.

3.4 Using the Tracking Generator

The integrated tracking generator can be used to characterize the frequency response of filters, amplifiers, and other RF components.

  1. Connect the Tracking Generator Output to the input of the device under test (DUT).
  2. Connect the output of the DUT to the RF Input of the spectrum analyzer.
  3. Enable the tracking generator function through the menu.
  4. Set the desired output power level (range: -30 dBm to 0 dBm).
  5. The spectrum analyzer will sweep synchronously with the tracking generator, displaying the DUT's frequency response.

3.5 Saving and Recalling Data

To save measurement data or instrument settings:

  1. Insert a USB storage device into the USB HOST port on the front panel.
  2. Pehia te Tiaki pātene i runga i te paewhiri mana.
  3. Follow the on-screen prompts to save the current trace, screenshot, or instrument settings to the USB device.
  4. To recall saved data, press the Maharahara button and select the desired file from the USB device.

4. Tiaki

4.1 Te horoi

To clean the instrument, use a soft, damp cloth. Do not use abrasive cleaners or solvents that could damage the display or casing. Ensure the device is powered off and disconnected from the power source before cleaning.

4.2 Tikanga Taiao

For optimal performance and longevity, operate the OWON XSA1015-TG within the following environmental conditions:

  • Te Waahi Mahi: 0 °C ki te 40 °C
  • Paemahana Rokiroki: -20 °C ki te 60 °C
  • Ensure adequate ventilation around the device. The rear panel includes heat vents to facilitate rapid heat dissipation during prolonged use.

4.3 Whakatupato Haumaru

Kia mau ki nga whakaritenga haumaru e whai ake nei:

  • Do not exceed the maximum safe input levels for the RF Input (+30 dBm / 50 VDC) and Tracking Generator Output (+20 dBm / 50 VDC).
  • The instrument contains no user-serviceable components inside. Refer all servicing to qualified personnel.
  • Me whakarite te turanga tika o te taputapu.

5. Te Raru

This section addresses common issues you might encounter with the OWON XSA1015-TG Spectrum Analyzer.

RaruraruTake peaRongoā
Kaore te taputapu i te hikoKāore he pūtake hiko; Kāore te taura hiko i honoa; Kua pakaru te fiusiCheck power cord connection; Verify power outlet; Inspect and replace fuse if necessary (refer to qualified personnel).
Karekau he tohu i whakaatuhiaInput signal too low; Incorrect frequency settings; RF input not connectedIncrease input signal level; Adjust Reference Level; Verify frequency span and center frequency; Ensure RF input is securely connected.
Display is frozen or unresponsiveSoftware error; Temporary glitchRestart the device by powering it off and on. If the issue persists, contact support.
Cannot save data to USBUSB drive not recognized; USB drive full or corruptedEnsure USB drive is properly inserted; Try a different USB drive; Format the USB drive (this will erase all data).

If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact OWON customer support for further assistance.

6. Whakatakotoranga

The following table details the technical specifications of the OWON XSA1015-TG Spectrum Analyzer.

TawhāWhakatakotoranga
TauiraXSA1015-TG
Awhe Auautanga9 kHz - 1.5 GHz
Displayed Average Noise Level (DANL)-150 dBm
Wāhanga Haruru-85 dBc/Hz @1 GHz, 10 KHz offset
Tapeke AmpLitude Tika<1.5 dB
Minimum Resolution Bandwidth (RBW)10 Hz
Tracking Generator Output Frequency Range100 kHz - 1.5 GHz
Tracking Generator Output Power Level Range-30 dBm - 0 dBm
Whakaatu10.4 inihi TFT LCD
Hononga Whakauru RF50 Ω, N-type female
Tracking Generator Output Connector50 Ω, N-type female
10 M Reference Input50 Ω, N-type female
Tauranga WhakawhitiwhitiUSB HOST, USB DEVICE, LAN, earphone port, VGA
Tuku Hiko100V - 240V AC, 50/60Hz
Taumaha5 kg (āwhiwhi. 11 lbs)
Te Waahi Mahi0 °C - 40 °C
Paemahana Rokiroki-20 °C - 60 °C
TiwhiketeEMC, IEC 61010-1:2000-1

7. Pūtāhui me te Tautoko

7.1 Nga Korero Whakaputanga

OWON products are typically covered by a limited warranty against defects in materials and workmanship. The specific terms and duration of your warranty may vary based on your region and point of purchase. Please refer to the warranty card included with your product or contact your local OWON distributor for detailed warranty information.

7.2 Tautoko Hangarau

For technical assistance, troubleshooting, or service inquiries, please contact OWON customer support. You can typically find contact information on the official OWON website or through your product's documentation. When contacting support, please have your product model number (XSA1015-TG) and serial number ready.

Ka taea hoki e koe te toro atu ki te OWON Store on Amazon mo etahi atu korero hua me nga rauemi.

Tuhinga e pa ana - XSA1015-TG

Preview Руководство пользователя анализатора спектра OWON XSA815-TG с генератором слежения
Данное руководство пользователя содержит подробные инструкции и спецификации для анализатора спектра OWON XSA815-TG с генератором слежения, охватывая настройку, эксплуатацию, измерения и устранение неполадок.
Preview Pukapuka Kaiwhakamahi mō te Mīhini Tātari Āhuahira Ringaringa o Owon HSA1000 Series
He pukapuka ā-ringa mō te Owon HSA1000 Series Handheld Spectrum Analyzer, e whakaatu ana i ngā whakatakotoranga, te whakamahinga, ngā whakatūpato haumaru, me te whakatau raruraru mō ngā tauira HSA1016, HSA1016-TG, HSA1036, HSA1036-TG, HSA1075, me te HSA1075-TG.
Preview Owon SDS1102+ Digital Oscilloscope with Function Generator
Detailed specifications and features of the Owon SDS1102+ Digital Oscilloscope, including its bandwidth, sampling rate, record length, automatic measurements, and waveform generator capabilities. The document also lists included accessories.
Preview Aratohu Tere mō te Raupapa OWON FDS: Pukapuka Kaiwhakamahi me ngā Tohutohu Whakahaere
Get started with your OWON FDS Series oscilloscope. This quick guide covers essential setup, safety, and operational details for its oscilloscope, function generator, power supply, and multimeter features. Visit www.owon.com.hk/download for full support.
Preview Tohutoro Kawa Whakahau SCPI Raupapa OWON HDS200
E whakamārama ana tēnei tuhinga i te kawa Paerewa Whakahau mō ngā Taputapu Ka taea te Whakahōtaka (SCPI) mō ngā oscilloscopes OWON HDS200 Series, e kapi ana i ngā tautuhinga whakapae, te hopu, te whirihoranga hongere, te whakaoho, ngā inenga, me te whakahaere whakaputa mahi.
Preview Ngā Whakatakotoranga Hangarau o te Oscilloscope Mamati Raupapa FDS a Owon
Ngā whakatakotoranga hangarau taipitopito mō ngā oscilloscopes mamati Owon FDS Series, tae atu ki ngā tauira FDS1102 me FDS1102A, e kapi ana i ngā āhuatanga mahi, ngā mahi whakaoho, te whakaputa ngaru, te tuku hiko, me ngā āheinga mita maha.