Tauira: FP-22

1. Kupu Whakataki

This manual provides essential instructions for the installation, operation, and maintenance of the Diversitech FP-22 Condensate Removal Pump. The FP-22 is designed to efficiently manage condensate water from furnaces and boilers, particularly in applications involving acidic and high-temperature conditions, up to 190°F (88°C).

Key features include a 22-foot maximum lift, steam-resistant electronics, vibration-dampening rubber feet, metal hang tabs for secure mounting, a built-in safety overflow switch, a check valve, and LED status indicators. The pump comes with four inlet holes, integrated P-traps, and 20 feet of 3/8" discharge tubing for a complete setup.

Diversitech FP-22 Condensate Pump, front-side view

Whakaahua 1.1: Taha-mua view of the Diversitech FP-22 Condensate Removal Pump. This image shows the overall design of the pump, including the red base and black motor housing.

2. Nga Korero Haumaru Nui

Tena panuihia nga tohutohu katoa i mua i te whakaurunga me te mahi. Ki te kore e whai i enei tohutohu ka pa mai pea te kino o nga rawa, te whara whaiaro, te mate ranei.

3. Ihirangi mokete

Manatokona kei roto katoa nga mea kei roto i te kete:

4. Tohutohu Tāuta

4.1 Te Whakapiki i te Puma

The FP-22 pump can be mounted on a flat surface or suspended using the integrated metal hang tabs. For optimal noise reduction and stability, utilize the vibration-dampening rubber feet.

Diversitech FP-22 Condensate Pump, side view showing hang tabs

Whakaahua 4.1: Taha view of the FP-22 pump, highlighting the metal hang tabs for secure mounting.

4.2 Condensate Inlet Connection

The pump features four inlet holes with built-in "P" traps. Connect the condensate drain line from your furnace or boiler to one of these inlets.

4.3 Discharge Line Connection

Connect the provided 3/8" discharge tubing to the pump's discharge outlet. Route the tubing to a suitable drain location, ensuring a continuous downward slope if possible, or a clear path for the pump to lift the water.

Diversitech FP-22 Condensate Pump, top view showing inlet and discharge ports

Whakaahua 4.2: Runga view of the FP-22 pump, illustrating the four inlet ports and the discharge connection point.

4.4 Hononga Hiko

Connect the pump's power cord to a dedicated 120V electrical outlet. Ensure the outlet is properly grounded and protected by a circuit breaker.

5. Mahi

The Diversitech FP-22 operates automatically. When condensate water fills the reservoir to a predetermined level, the internal float switch activates the pump, which then discharges the water through the discharge tubing. Once the water level drops, the pump deactivates.

5.1 Tohu LED

The pump is equipped with LED indicators to provide status updates:

5.2 Safety Overflow Switch

A built-in safety overflow switch provides an additional layer of protection. If the water level rises above the normal operating range, this switch will activate, typically shutting down the connected HVAC equipment to prevent overflow and water damage. Consult your HVAC system's manual for wiring instructions for this safety feature.

6. Tiaki

Regular maintenance ensures optimal performance and extends the life of your condensate pump.

6.1 Te horoi i ia wa

Perform this cleaning at least once every six months, or more frequently if the condensate quality is poor or the pump is in heavy use.

7. Te Raru

This section addresses common issues you might encounter with your FP-22 condensate pump.

RaruraruTake peaRongoā
Kare te papu e ka ana.
  • Kāore he hiko mō te papu.
  • Float switch stuck in down position.
  • Rahunga motopaika.
  • Tirohia te hononga hiko me te ara iahiko.
  • Inspect float for obstructions; clean reservoir.
  • Whakapa atu ki nga kaimahi ratonga whai tohu.
Ka rere tonu te papu.
  • Float switch stuck in up position.
  • Discharge line blocked or kinked.
  • Check valve faulty.
  • Inspect float for obstructions; clean reservoir.
  • Clear blockage or straighten kink.
  • Inspect/replace check valve.
He haruru te papu.
  • Vibrations due to improper mounting.
  • Ngā para i roto i te impeller papu.
  • Ensure pump is level and rubber feet are utilized.
  • Disconnect power and inspect impeller for debris.
Puka wai.
  • Pump failure (motor or float switch).
  • Discharge line blockage.
  • Inadequate pump capacity for condensate volume.
  • Refer to "Pump does not turn on" or "Pump runs continuously" solutions.
  • Clear discharge line.
  • Verify pump capacity meets system requirements.

8. Whakatakotoranga

ĀhuahiraTaipitopito
Tau tauiraFP-22
Voltage120 Volts
Horsepower (HP)1 / 30 HP
Hikinga Mōrahi22 Puawai
Rere Rere Morahi2.1 Karini mo ia Meneti
Maximum Condensate Temperature190°F (88°C)
Rahi Hua (L x W x H)6" x 6.75" x 12.25"
Taumaha Tūemi5 Pauna
RauemiStainless Steel (internal components), Durable Plastic (housing)
Puna ManaHiko Hiko
Nga waahanga motuhakeSteam-resistant electronics, Safety overflow switch, Check valve, Vibration-dampening feet, Metal hang tabs, Integrated P-traps

9. Pūtāhui me te Tautoko

For warranty information and technical support, please refer to the official Diversitech webpaetukutuku, whakapā atu ranei ki ta raatau tari ratonga kaihoko. Puritia to riiki hoko hei tohu mo te hoko.

Kaihanga: DiversiTech Corporation

Webpae: www.diversitech.com (Exoampte hono, ka rereke pea te hono pono)

For service or parts, please contact a qualified HVAC technician or the manufacturer directly.

Tuhinga e pa ana - FP-22

Preview Pukapuka Tāutanga me te Whakahaere o te Papu Whakapūhau a DiversiTech
He aratohu whānui mō te tāuta me te whakahaere i ngā papu waikura a DiversiTech (CP-22, CP-22LP, raupapa CP-22T). Kei roto ko ngā tohutohu haumaru, ngā whakaritenga, ngā mahi tāutanga, ngā taipitopito whakahaere, te rapurongoā, me ngā mōhiohio pūtāhui.
Preview Aratohu Tāutanga me te Whakahaere o te Papu Whakapūngao DiversiTech
Kei roto i tēnei aratohu ngā tohutohu taipitopito mō te tāuta, te whakahaere, me te tiaki i ngā papu waikura a DiversiTech (raupapa CP-22). Kei roto ngā whakatūpato haumaru, ngā whakatakotoranga, ngā ihirangi o te kete, te tāutanga taahiraa-i-te-taahiraa, te rapurongoā, me ngā mōhiohio pūtāhui.
Preview Aratohu Tāutanga o te Papu Whakapūngao kua Whakatauria e DiversiTech Plenum
He aratohu whānui mō te tāutanga, te whakahaere, me te tiaki mō ngā Papu Whakapūmau Whakapūmau a DiversiTech CP-22LP-P me te CP-22LP-230-P. Kei roto ko ngā whakatūpato haumaru, ngā whakaritenga, ngā tohutohu tāutanga taahiraa-i-te-taahiraa, ngā tohutohu rapurongoā, me ngā mōhiohio pūtāhui.
Preview Hef-T-Bracket He Aratohu Whakauru - 230-B2L
Ngā tohutohu tāutanga me ngā whakaritenga mō te DiversiTech Hef-T-Bracket 230-B2L, he whāriki pakitara mō ngā waeine whakamatao hauhautanga.
Preview Aratohu Tāutanga o te Paepae Pakitara Diversitech HW-600 mō ngā Pūnaha Wehewehe Iti
He aratohu tāutanga whānui mō te whāriki pakitara Diversitech HW-600, i hangaia mō te whakairi i ngā waeine hauhautanga iti wehewehe o waho. Kei roto ko te rārangi wāhanga, ngā tohutohu huihuinga, me ngā mōhiohio haumaru nui.
Preview DiversiTech ACB Series Taiapa Taiepa Pūnaha mo nga Waehanga A/C Condensing
Ko nga whakaritenga hangarau me nga aratohu whakaurunga mo nga punaha taiapa pakitara raupapa DiversiTech ACB, tae atu ki nga tauira ACB-30, ACB-36, ACB-42, me ACB-48, i hangaia mo nga waeine whakataa A/C.