Nga Tohutohu Haumaru Nui
Pānuihia nga tohutohu katoa i mua i te whakauru, te whakamahi ranei i tenei whakamahana. Ki te kore e whai i enei tohutohu ka pa mai pea te ahi, te ru hiko, te whara kino, te mate ranei.
- Hononga Hiko: This heater operates on 240 Volts. All wiring must be performed by a qualified electrician and comply with national and local electrical codes.
- Whakapapa: Me whakamahana tenei whakamahana.
- Tauwāhi: Do not install the heater near flammable materials, in areas where gasoline, paint, or other flammable liquids are stored, or where explosive dust is present. Maintain minimum clearances from walls and other objects as specified in the installation section.
- Tirohanga: Me kati te tirotiro ina whakamahia tetahi whakamahana e nga tamariki, e tata ana ranei ki nga tamariki, i nga turoro ranei, me nga wa katoa ka waiho te whakamahana me te kore e tiakina.
- Te wera nui: To avoid overheating, do not cover the heater. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the heater.
- Tiaki: Disconnect power at the main service panel before performing any maintenance or cleaning.
- Tauhoko: A separate thermostat is required for operation and is sold separately. Ensure the thermostat is compatible with a fan-forced heater.
Ka mutu te huaview
The Stelpro pulsair RWF0502W is a 240V wall-mounted fan heater designed for supplemental heating in various rooms such as bedrooms, home offices, and living rooms. It utilizes both convection and forced air heating methods to efficiently distribute warmth.

Mua view of the Stelpro pulsair RWF0502W wall fan heater, showing the fan grille and lower air outlet.

Diagram showing the dimensions of the Stelpro pulsair RWF0502W wall fan heater: 17 1/8 inches (435 mm) height, 8 11/16 inches (220 mm) width, and 3 3/16 inches (80 mm) depth.
Tāutatanga
Rārangi Arowhai i mua i te Tāutatanga:
- Me mohio kua momotuhia te hiko i te wehenga ara iahiko matua.
- Manatokohia ko te tuku voltage matches the heater's rating (240V).
- Confirm you have a compatible wall thermostat (sold separately).
- Kohikohia nga taputapu e tika ana: te huriwiri, te tango waea, te drill, te taumata, te riipene ine.
Kōwhiringa Whakapuru:
The RWF0502W heater can be either surface-mounted directly to the wall or recessed into the wall for a flush finish. Ensure adequate clearance from floors, ceilings, and adjacent walls as per local codes and manufacturer recommendations.

The Stelpro pulsair RWF0502W wall fan heater installed in a modern entryway, positioned below a plant and mirror.

The Stelpro pulsair RWF0502W wall fan heater installed on a blue wall in an entryway, with coats and shoes nearby.
Hononga Hiko:
This heater requires a 240V hardwired connection. Follow the wiring diagram provided and ensure all connections are secure and properly insulated. Connect the heater to a dedicated circuit protected by the appropriate circuit breaker.

Diagram illustrating the 240V hardwired connection for the Stelpro pulsair RWF0502W wall fan heater, showing wires connecting within a junction box.
- Turn off power at the main electrical panel.
- Remove the front grille of the heater to access the wiring compartment.
- Connect the supply wires to the heater's terminals according to the wiring diagram. Ensure proper grounding.
- Secure all connections with wire nuts and ensure no bare wires are exposed.
- Reattach the front grille.
- Install the external wall thermostat according to its manufacturer's instructions.
Mahi
The Stelpro pulsair RWF0502W heater is controlled by an external wall thermostat (not included). Once installed and wired correctly, follow these steps:
- Whakahiko: Restore power to the heater circuit at the main electrical panel.
- Tautuhinga Thermostat: Adjust the external thermostat to your desired temperature. The heater will activate when the room temperature falls below the set point.
- Mahi Tuatahi: During the first few minutes of operation, the heater may emit a slight odor due to the burning off of manufacturing residues. This is normal and will dissipate quickly.
- Awhe Pawera: The heater is designed to operate within a temperature range of 5°C (41°F) to 30°C (86°F).
For optimal performance, avoid placing furniture or other obstructions directly in front of the heater's air outlets.
Te tiaki
Regular maintenance ensures efficient and safe operation of your Stelpro pulsair heater. Always disconnect power at the main circuit breaker before performing any maintenance.
- Te horoi:
- Horoia te taha waho o te whakamahana ki te wai ngohengohe,amp kakahu. Kaua e whakamahi i nga kai horoi me nga whakarewa.
- Periodically vacuum the air intake and outlet grilles to remove dust and lint buildup.
- Tirotiro: Annually inspect the heater for any signs of damage, loose connections, or unusual wear. If any issues are found, contact a qualified electrician for repair.
- Kāore he hinu whakahinuhinu: Ka whakahinuhinu tonu te motuka, kaore e hiahiatia he hinu taapiri.
Raparongoā
If your Stelpro pulsair heater is not operating correctly, consult the following table before contacting customer support.
| Raruraru | Take pea | Rongoā |
|---|---|---|
| Kare te whakamahana e ka ana. | Kaore he mana ki te waeine. He iti rawa te whakamaarama. I whati te whatiwhati ara iahiko. | Check main electrical panel. Whakanuia te tautuhinga thermostat. Tautuhi ano i te wehenga iahiko. |
| He iti rawa te wera o te whakamahana. | He nui rawa te rūma mō te whakamahana. Airflow obstructed. He raruraru whakatikatika i te pāmahana. | Ensure heater is appropriately sized for the room. Clear obstructions from grilles. Consult thermostat manual or a qualified electrician. |
| Haruru rereke i te wa e mahi ana. | Nga waahanga wetekina. He para i roto i te mea tahi. | Momotuhia te hiko, ka tirotirohia mēnā he wāhanga koretake. Disconnect power and carefully remove any debris. If noise persists, contact support. |
| He maha rawa nga huringa o te whakamahana. | Thermostat location or setting. Kua whakahohehia te whakamaru wera. | Relocate thermostat away from drafts or direct heat sources. Adjust thermostat differential. Ensure grilles are clear and heater is not covered. Allow unit to cool. |
Whakatakotoranga
| Āhuahira | Taipitopito |
|---|---|
| Waitohu | Stelpro |
| Tau tauira | RWF0502W |
| Momo Whakaeke | Wall Mount (Surface or Recessed) |
| Momo Rūma | Rūma moenga, Tari Kāinga, Rūma Noho |
| Voltage | 240 Volts |
| Ampwhakatipu | 2.08 Amps |
| Tikanga Whakawera | Convection, Forced Air |
| Te Tautuhinga Maamaa Min | 5 Degrees Celsius (41°F) |
| Tautuhinga Paemahana Max | 30 Degrees Celsius (86°F) |
| Taumaha Tūemi | 7 pauna |
| Ahu mōkihi | 17.72 x 9.13 x 3.58 inihi |
| UPC | 626296002285 |
Pūtāhui
Stelpro products are manufactured to high standards and are covered by a limited warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Stelpro webpae. Puritia to tohu hoko mo nga kereme whakamana.
Tautoko Kiritaki
For technical assistance, replacement parts, or further inquiries, please contact Stelpro customer service. Contact information can typically be found on the product packaging, the official Stelpro website, or by referring to the documentation included with your purchase.
Note: Always provide your product model number (RWF0502W) when contacting support.