This manual provides instructions for the safe and effective use of the Extech MM750W Datalogging True RMS Multimeter. The MM750W is a robust, full-featured multimeter designed for professional use, offering 14 functions including non-contact AC voltage detection and Type K temperature measurements. Its CAT IV safety rating ensures protection in industrial environments. A key feature is its wireless datalogging capability via Bluetooth, allowing real-time data transmission to smart devices using the ExView W-Series app.

Extech MM750W Datalogging True RMS Multimeter front view

Whakaahua 1: Mua view of the Extech MM750W Datalogging True RMS Multimeter, showing the display, function dial, and input jacks.

2. Nga korero haumaru

WARNING: Read and understand all safety information and operating instructions before using this meter. Failure to do so may result in serious injury or death.

  • Kia mau tonu ki nga ture haumaru o te rohe me te motu.
  • Kaua e whakamahia te mita mēnā te āhua kua pakaru, kua pakaru rānei ngā taura whakamātautau.
  • Me whakarite kei te tūranga tika te pana mahi mō te inenga e mahia ana.
  • Observe all terminal ratings and never exceed the maximum input limits.
  • Kia tupato ki te mahi tahi me te voltagneke atu i te 30V AC RMS, 42V tihi, 60V DC rānei, nā te mea he mōrearea ru ēnei.
  • Mauria ngā taputapu tiaki whaiaro (PPE) e tika ana, pērā i ngā mōhiti haumaru me ngā karapu whakamarumaru.
  • The MM750W is rated for CAT IV 600V and CAT III 1000V. Understand the implications of these categories for safe measurement.

3. Nga waahanga matua

  • Wireless Datalogging: Records and transmits over 15,000 readings to iOS and Android devices via Bluetooth Datalogging Module (DAT12) for remote viewing using the free ExView W-Series app.
  • 14 Measurement Functions: Includes AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Duty Cycle, Diode Test, Continuity, Non-Contact AC Voltage (NCV), and Type K Temperature.
  • RMS Pono: Provides accurate AC measurements for non-sinusoidal waveforms.
  • AC µA Function: Ideal for HVAC flame rod current measurements.
  • Hopu Raraunga: Allows snapshots of the measurement area with a connected smartphone or tablet camera to document date/time stamps and measurement data.
  • Whakatauranga Haumaru CAT IV: Provides enhanced protection in industrial environments.

4. He aha kei roto i te Pouaka

Me manatoko kei reira ngā taonga katoa, ā, kāore he pakaru i te wā e wetewete ana:

  • Extech MM750W Multimeter
  • Nga Tohu Whakamatau (kotahi te whero, kotahi te pango)
  • Type K Bead Wire Temperature Probe
  • Bluetooth Datalogging Module (DAT12)
  • 9V Battery (installed or separate)
  • Te Tino Whakahaere Kino
Extech MM750W Multimeter with included accessories: test leads, temperature probe, Bluetooth module, and carrying case

Figure 2: The Extech MM750W Multimeter shown with its complete set of accessories, including test leads, a Type K temperature probe, the DAT12 Bluetooth module, and a soft carrying case.

5. Tatūnga

5.1. Tāuta Pūhiko

  1. Me mohio kua whakawetohia te mita.
  2. Locate the battery compartment on the rear of the meter.
  3. Use a screwdriver to remove the screw securing the battery cover.
  4. Tango kia ata tirohia te taupoki puhiko.
  5. Connect a 9V battery to the battery clips, observing correct polarity.
  6. Whakanohoia te pākahiko ki roto i te wāhanga ka whakahokia te taupoki, ka whakau ki te tīwiri.

5.2. Test Lead Connection

Always connect the test leads correctly for the desired measurement function.

  • Mo te nuinga voltage, resistance, continuity, and diode measurements, insert the red test lead into the VΩµA input jack and the black test lead into the COM input jack.
  • For current measurements up to 600mA, insert the red test lead into the VΩµA input jack and the black test lead into the COM input jack.
  • For current measurements up to 10A, insert the red test lead into the 10A input jack and the black test lead into the COM input jack.
Whakamuri view of Extech MM750W Multimeter with test leads connected and stored

Whakaahua 3: Whakamuri view of the Extech MM750W Multimeter, showing the integrated test lead holders and the battery compartment cover. The test leads are shown connected and stored.

5.3. Bluetooth Datalogging Module (DAT12)

The DAT12 module enables wireless communication with smart devices.

  1. Insert the DAT12 module into the dedicated port on the top of the multimeter.
  2. Download the free ExView W-Series app from your device's app store (iOS or Android).
  3. Whakahohea te Bluetooth i runga i to whakaaro atamai.
  4. Whakatuwheratia te ExView W-Series app and follow the on-screen instructions to pair with the MM750W.

6. Mahi

6.1. Ngā Ine Taketake

Turn the rotary switch to the desired function. The display will show the measurement value.

  • Voltage (V~, V-): Tīpakohia AC ranei DC voltage. Connect test leads in parallel with the circuit.
  • Current (A~, A-): Select AC or DC current. Connect test leads in series with the circuit. Ensure correct input jack (µA/mA or 10A).
  • Ātete (Ω): Turn off power to the circuit. Connect test leads across the component.
  • Tonu ()))): Turn off power. Connect test leads across the circuit. A tone indicates continuity.
  • Whakamatau Diode (→|): Turn off power. Connect test leads across the diode.
Electrician using Extech MM750W Multimeter to measure voltage i roto i te papa hiko

Figure 4: An electrician safely measuring voltage within an electrical panel using the Extech MM750W Multimeter. The meter's display is visible, showing a reading.

6.2. Nga Mahi Arā Atu Anō

  • Kore-Whakapā AC Voltage (NCV): Position the top of the meter near an AC voltage source. The NCV indicator will illuminate, and an audible tone will sound if AC voltagka kitea e.
  • Type K Temperature (Temp): Insert the Type K bead wire probe into the VΩµA and COM jacks (observing polarity). Select the temperature function.
  • MAX / MIN: Press the MAX/MIN button to record the maximum and minimum readings during a measurement session.
  • Relative Mode (REL): Press the REL button to store the current reading as a reference and display subsequent measurements as a deviation from this reference.
  • Frequency/Duty Cycle (Hz/%): Select the appropriate function to measure frequency or duty cycle of an AC signal.
Man using Extech MM750W Multimeter with Type K temperature probe to measure temperature of a furnace flue

Figure 5: A technician using the Extech MM750W Multimeter with its Type K temperature probe to measure the temperature of a furnace flue, demonstrating the meter's temperature measurement capability.

6.3. Datalogging and Bluetooth Connectivity

Ko te ExView W-Series app enhances the functionality of your MM750W.

  1. Ensure the DAT12 module is connected and the meter is paired with your smart device via the ExView W-Series app.
  2. I roto i te taupānga, ka taea e koe view real-time readings, initiate datalogging sessions, and configure logging intervals.
  3. The app allows you to generate reports, analyze collected data, and add notes or photos (taken with your smart device camera) to specific readings for comprehensive documentation.
  4. Your smart device can also serve as a second display for convenient viewing or sharing of measurements from a safe distance.

7. Tiaki

7.1. Te horoi

Horoia te pouaka o te mita ki te pānuitangaamp kakahu me te hopi horoi ngawari. Kaua e whakamahia he mea whakakoi, he mea whakarewa rānei. Me whakarite kia maroke rawa te mita i mua i te whakamahinga.

7.2. Whakakapinga Pūhiko

When the battery symbol appears on the display, replace the 9V battery as described in Section 5.1. Prompt battery replacement ensures accurate readings and proper meter function.

8. Te Raru

RaruraruTake peaRongoā
Kaore te mita i te hiko.Kua mate, kua hē ranei te whakaurunga o te pākahiko.Replace or correctly install the 9V battery.
Ko nga panui kore tika.Incorrect function selected; damaged test leads; low battery.Verify function switch position; inspect/replace test leads; replace battery.
Nga take hononga Nihokikorangi.DAT12 module not properly inserted; Bluetooth disabled on smart device; app not open.Ensure DAT12 is fully inserted; enable Bluetooth; open ExView W-Series app and retry pairing.
"OL" e whakaaturia ana.Overload, measurement exceeds meter's range.Ensure measurement is within the meter's specified range for the selected function.

9. Whakatakotoranga

TawhāUara
Tau tauiraMM750W
WaitohuExtech
Hunga Hua2.2 x 7.7 x 3.7 inihi
Taumaha Tūemi16 aune (1 Pauna)
Puna ManaWhakahikohia te Pūhiko (9V)
Whakatauranga HaumaruCAT IV 600V, CAT III 1000V
Datalogging Capacity15,000 panui
HonongaBluetooth (via DAT12 module)
RMS ponoAe
Kore-Whakapā AC Voltage (NCV)Ae
Te Ine MaamaMomo K

10. Pūtāhui me te Tautoko

Extech Instruments provides a warranty for this product against defects in materials and workmanship. Specific warranty terms and duration may vary by region and purchase date. Please refer to the warranty card included with your product or visit the official Extech webpae mo nga korero taipitopito taurangi.

For technical support, service, or replacement parts, please contact Extech Customer Service. Contact information can typically be found on the Extech webpaetukutuku, i roto rānei i ngā tuhinga e haere tahi ana me tō hua.

Tuhinga e pa ana - MM750W

Preview Extech Multimeters: He Aratohu Matawhānui mo nga Inetere Mamati me nga Kaiwhakamatau Wehenga
Torotoro te awhe Extech o nga mita maha matihiko (DMMs) me nga kaiwhakamatautau whakamatao, tae atu ki nga raupapa penei i te EX300, EX350, EX360, EX400, EX500, MM750W, MG320, MG325, DM220, MN35/36, me 381676A. Ko nga ahuatanga ko te True RMS, NCV, LPF, LoZ, ine ine mahana, me te tuhi raraunga ahokore.
Preview EXTECH MG320 Insulation Tester + DMM User Manual
User manual for the EXTECH MG320 True RMS Insulation Resistance CAT IV 600V DMM, covering features, safety, operating instructions, maintenance, and specifications.
Preview EXTECH EX5xxA Series: Heavy Duty Industrial True RMS Multimeters
Explore the EXTECH EX5xxA Series of rugged, IP67-rated industrial multimeters. Featuring True RMS, CAT IV-600V safety, and drop-proof design, these multimeters are built for demanding electrical testing environments. Models include EX505A, EX520A, and EX530A.
Preview Pukapuka Kaiwhakamahi mō te Mita Maha RMS Pono a Extech EX470A me te Inemahana IR
He pukapuka kaiwhakamahi whānui mō te Mita Maha Aunoa True RMS me te Inemahana IR a Extech EX470A, e kapi ana i te haumaru, te whakahaere, ngā whakaritenga, te tiaki, me ngā mōhiohio pūtāhui.
Preview Aratohu Kaiwhakamahi mō te Mita Maha Pūkoro Extech DM100
He aratohu kaiwhakamahi tēnei mō te Mita Maha Pūkoro Extech DM100 4000 Count Autoranging, e kapi ana i te haumaru, ngā whakaritenga, te whakahaere, ngā āhuatanga, me te tiaki.
Preview Pukapuka Kaiwhakamahi mō te Whakamātautau Tonu Mahi Taumaha Extech ET40
He pukapuka āwhina mō te Extech ET40 Heavy Duty Continuity Tester. Akohia me pēhea te whakamātautau haumaru me te whai hua i te haere tonu o ngā wāhanga kāore i te whakakahangia, ngā fiusi, ngā pana, ngā whakawhiti, ngā waea hiko, me ngā papa hiko.