Wilo TE015

Pukapuka Kaiwhakamahi mō te Wilo Make Hot Water Circulaton Pump Star RS 25/6

Tauira: TE015

Kupu Whakataki

This manual provides essential information for the safe and efficient operation, installation, and maintenance of the Wilo Make Hot Water Circulation Pump Star RS 25/6. Please read these instructions carefully before installation and initial startup.

The Wilo Star RS 25/6 is designed for circulating hot water in heating systems. It features a flow rate of 40 to 64 Liters Per Minute (LPM) and a head of 6 to 4 meters. The pump is designed for 25 mm suction and delivery pipe sizes.

Nga Tohutohu Haumaru

Adherence to these safety instructions is crucial for preventing personal injury and property damage. Always follow local regulations and standards.

Wilo-Star RS Do's and Don'ts

Whakaahuatanga Whakaahua: A graphic illustrating "Wilo-Star RS Do's and Don'ts". The "Do's" side, marked with green checkmarks and a thumbs-up icon, includes: "Read the Manual", "Proper Installation", "Initial Priming", "Proper Electrical connection", and "Do the Earthing connection". The "Don'ts" side, marked with red crosses and a thumbs-down icon, includes: "Avoid the Piping Leakages", "Never Run pump by closing the Suction valve", "Do not use Under sizing and Oversizing Pipes", and "Avoid the dry running of pump".

Ka mutu te huaview

The Wilo Star RS 25/6 is a robust hot water circulation pump designed for reliable performance in various heating applications. Its compact design and efficient operation make it suitable for residential and light commercial use.

Wilo Star RS 25/6 Hot Water Circulation Pump

Whakaahuatanga Whakaahua: He tata view of the Wilo Star RS 25/6 hot water circulation pump. The pump is green with a black electrical box on top. A circular label on the front shows "Wilo", energy efficiency class (likely B or C), and technical specifications like voltage (1~230V/50Hz) and current (max 0.21A). The model number "Star-RS25/4" and "Art-No. 4032954/ 0601" are visible. The pump has inlet and outlet connections.

Wilo-Star RS, RSD Installation and Operating Instructions Cover

Whakaahuatanga Whakaahua: The cover page of the Wilo-Star RS, RSD installation and operating instructions manual. The top of the page has "Pioneering for You" and the Wilo logo. Below that, "Wilo-Star RS, RSD" is prominently displayed. The main part of the image shows two different models of Wilo pumps. Text at the bottom indicates the manual is available in English ("en Installation and operating instructions"), French ("fr Notice de montage et de mise en service"), Spanish ("es Instrucciones de instalación y funcionamiento"), Russian ("ru Инструкция по монтажу и эксплуатации"), Ukrainian ("uk Інструкція з монтажу та експлуатації"), and Serbian ("sr Uputstvo za ugradnju i upotrebu").

Tatūnga me te Tāuta

Proper installation is critical for the pump's performance and longevity. Ensure all steps are followed carefully.

  1. Tauwāhi Whakapuru: Choose a suitable location that allows for easy access for maintenance and is protected from extreme temperatures and moisture.
  2. Hononga paipa: Connect the pump to the heating system's pipes. The pump is designed for 25 mm suction and delivery pipe sizes. Ensure all connections are tight and leak-free. Use appropriate sealing materials.
  3. Hononga Hiko: Connect the pump to the electrical supply according to local electrical codes and the pump's specifications (1~230V/50Hz). Ensure proper earthing. This step must be performed by a qualified electrician.
  4. Whakataki Tuatahi: Before first operation, the pump must be primed. Fill the heating system with water and vent any air from the system and the pump. This prevents dry running.

Nga Tohutohu Whakahaere

Once installed and primed, the pump is ready for operation. Follow these guidelines for optimal performance.

Te tiaki

Regular maintenance ensures the longevity and efficient operation of your Wilo pump.

Raparongoā

This section provides solutions to common issues you might encounter with your pump.

RaruraruTake peaRongoā
Kaore e timata te papuNo power supply; Motor jammed; Air in pumpCheck power connection and circuit breaker; Attempt to free motor (consult manual); Vent the pump and system.
He haruru te papuAir in system; Cavitation due to closed suction valve; Incorrect pipe sizingVent the system thoroughly; Ensure suction valve is fully open; Verify pipe sizes are appropriate (25 mm).
No water circulation or low flowAir in pump; Closed valves; Clogged impeller; Dry runningVent the pump; Open all necessary valves; Inspect and clean impeller (power off first); Ensure pump is always filled with water.
Nga turuturu i nga honongaNga hononga korekore; hiri kua pakaruTighten connections; Replace damaged seals.

Whakatakotoranga Hangarau

Pūtāhui me te Tautoko

For warranty information and technical support, please refer to the official Wilo documentation included with your product or visit the official Wilo webpae. Puritia to riirii hoko hei tohu mo te hoko mo nga kereme whakamana.

For specific inquiries or service, contact Wilo customer service or an authorized service partner in your region.

Tuhinga e pa ana - TE015

Preview Wilo-Star RS, RSD, ST, RSG, AC Circulating Pump Tāuta me ngā Tohutohu Whakahaere
Te whakaurunga me nga tohutohu whakahaere mo Wilo-Star RS, RSD, ST, RSG, AC circulating pumps, e hipoki ana i nga korero whanui, te haumaru, te kawe, te whakaahuatanga, te huihuinga, te whakaurunga, te hononga hiko, te mahi, te tiaki, me te rapu raruraru.
Preview Wilo-Star-Z/-ZD Einbau- und Betriebsanleitung
Utu Whakanoho- und Betriebsanleitung für die Wilo-Star-Z/-ZD Zirkulationspumpen, inklusive Sicherheitshinweisen, technischen Daten und Wartungsanleitungen.
Preview Wilo-Star-Z/-ZD: Einbau- und Betriebsanleitung
Umufassende Anleitung zur Installation und zum Betrieb von Wilo-Star-Z/-ZD Zirkulationspumpen, einschließlich Sicherheitshinweisen, technischen Daten und Wartungsanleitungen.
Preview Каталог насосов Wilo для бытового применения: отопление, водоснабжение, водоотведение
Обзор высокоэффективных циркуляционных насосов Wilo для систем отопления, водоснабжения и водоотведения. Информация для продавцов и монтажников.
Preview Wilo-Star-Z 15 TT Installation and Operating Instructions
Comprehensive guide for installing, operating, and maintaining the Wilo-Star-Z 15 TT circulation pump, including technical specifications, safety information, and troubleshooting. Designed for drinking water systems.
Preview Wilo-Star-Z NOVA Installation and Operating Instructions
Comprehensive installation and operating instructions for the Wilo-Star-Z NOVA circulation pump, covering setup, usage, safety guidelines, and troubleshooting. Essential guide for proper installation and maintenance.