1. Kupu Whakataki me nga Korero Haumaru
This manual provides essential information for the safe and efficient operation and maintenance of your MPS CY001 Bootstrap Compressor. Please read all instructions carefully before use to prevent injury and ensure proper function.
Whakatupato Haumaru Whanui:
- Always wear appropriate personal protective equipment (PPE), including eye protection, when operating the compressor.
- Ensure the compressor is placed on a stable, level surface in a well-ventilated area.
- Do not exceed the maximum rated pressure of the compressor or any connected tools/equipment.
- Regularly inspect all hoses, fittings, and gauges for damage or leaks. Replace any damaged components immediately.
- Disconnect the power source before performing any maintenance or repairs.
- Keep children and unauthorized personnel away from the operating compressor.
2. Hua Neke Atuview
The MPS CY001 Bootstrap Compressor is designed for applications requiring precise pressure regulation. It features a robust design with clear pressure gauges for monitoring supply and discharge pressures.
Āhuatanga matua:
- Whakakahoretanga Tukunga: 200 PSI Morahi
- He Whakaputanga 15 ki te 150 PSI
- Equipped with two 0-200 PSI gauges for accurate pressure readings.

Figure 2.1: Product label detailing model and pressure specifications.

Whakaahua 2.2: Mua view of the compressor with gauges and regulator.

Figure 2.3: Close-up of gauges and regulator.
3. Whakatakotoranga
| Whakatakotoranga | Uara |
|---|---|
| Ingoa Tauira | CY001 |
| Waitohu | MPS |
| Kaihanga | MPS |
| Hunga Hua | 16 x 7 x 9 inihi |
| Taumaha Tūemi | 16 pauna |
| Discharge Pressure (Maximum) | 200 PSI |
| Pehenga Tuku | 15 ki te 150 PSI |
| Kāhua | Kawe |

Figure 3.1: Serial number identification label.

Figure 3.2: Additional identification tag.
4. Tatūnga
Proper setup is crucial for the safe and effective operation of your compressor.
Hipanga Tāuta:
- Wewete ana: Āta tango i te kōpeke i tōna tākai. Tirohia mo nga pakaru o te kaipuke.
- Turanga: Position the compressor on a firm, level surface. Ensure adequate ventilation around the unit to prevent overheating.
- Hononga: Connect the air supply line to the designated inlet port. Connect the discharge line to your pneumatic tool or system. Ensure all connections are secure and leak-free.
- Puna Hiko: Connect the compressor to an appropriate power source as specified by the manufacturer (if applicable for an electric model, though this appears to be a pneumatic booster).

Whakaahua 4.1: Taha view of the compressor, illustrating connection points.

Whakaahua 4.2: Raro view, showing connection and mounting details.
5. Nga Tohutohu Whakahaere
Follow these steps for safe and effective operation of your MPS CY001 Bootstrap Compressor.
Mahinga Mahi:
- Taki Tuatahi: Before starting, ensure all connections are tight and there are no visible signs of damage or leaks.
- He Whakaputanga Gradually introduce the supply air pressure to the compressor. Monitor the supply pressure gauge to ensure it is within the 15 to 150 PSI range.
- Adjust Discharge Pressure: Use the pressure regulator (typically the knob located between the gauges) to set the desired discharge pressure. Observe the discharge pressure gauge to ensure it does not exceed the 200 PSI maximum.
- Mahi Aroturuki: During operation, regularly check both gauges to ensure pressures remain within safe and desired limits. Listen for any unusual noises or air leaks.
- Whakaweto: To shut down, first relieve the pressure from the discharge line. Then, gradually reduce and shut off the supply air pressure.
6. Tiaki
Ko te tiaki i nga wa katoa ka mau te roa me te pono o te mahi o to compressor.
Apiti tiaki:
- Ia rā/i mua i ia Whakamahinga:
- Inspect all hoses and fittings for wear, cracks, or leaks.
- Check gauges for proper function and accuracy.
- Ensure the compressor is clean and free of debris.
- Ia marama/Ia wā:
- Check mounting bolts and fasteners for tightness.
- Inspect the regulator for smooth operation.
- Ka hiahiatia:
- Clean the exterior of the compressor with a damp kakahu. Kaua e whakamahia nga matū kino.
- Replace any worn or damaged components with genuine MPS replacement parts.
7. Te Raru
This section addresses common issues you might encounter with your MPS CY001 Bootstrap Compressor.
| Raruraru | Take pea | Rongoā |
|---|---|---|
| No discharge pressure | No supply pressure; Regulator closed; Leak in system | Check supply air; Open regulator; Inspect for and repair leaks |
| Te pehanga whakaheke iti | Insufficient supply pressure; Regulator setting too low; Leak in system | Increase supply pressure; Adjust regulator; Inspect for and repair leaks |
| Ka turuturu te hau | Loose fittings; Damaged hoses/seals | Tighten all connections; Replace damaged components |
| Gauges not reading correctly | Damaged gauge; Blocked port | Replace faulty gauge; Clear any obstructions |
8. Pūtāhui me te Tautoko
Warranty information for the MPS CY001 Bootstrap Compressor is not provided within this document. For details regarding warranty coverage, technical support, or to order replacement parts, please contact MPS directly through their official customer service channels.