1. Kupu Whakataki
The AstralPool NA6888 is a sophisticated regulator, controller, and display unit designed for integration with AstralPool heat pump systems. This device provides essential control and monitoring functionalities for your heat pump, ensuring efficient and reliable operation. Please note that this unit is not compatible with remote control systems.
This manual provides detailed instructions for the proper installation, operation, and maintenance of your NA6888 unit. Please read this manual thoroughly before installation and use to ensure safe and optimal performance.
2. Nga korero haumaru
Always adhere to the following safety guidelines to prevent injury or damage to the unit:
- Haumaru Hiko: This unit operates on 220V AC. All electrical connections must be performed by a qualified electrician in accordance with local electrical codes and regulations. Ensure the power supply is disconnected before any installation or maintenance work.
- Tiaki Taiao: The NA6888 unit has an IP65 protection rating, meaning it is protected against dust ingress and low-pressure water jets from any direction. However, avoid direct high-pressure water jets or submersion.
- Whakamahi Tika: Use the device only for its intended purpose as a regulator, controller, and display for AstralPool heat pumps. Do not attempt to modify the unit.
- Te whakahaere: Handle the unit with care to avoid physical damage.
3. Nga Hua o te Hua
The NA6888 unit offers a range of features for comprehensive heat pump management:
- Mana Whakakotahi: Combines regulation, control, and display functions in a single compact unit.
- Pūoko Whakauru: Supports dedicated inputs for a Temperature Sensor (T1) and a Defrost Sensor (T2).
- Ngā Whakauru Whakaoho: Features three external alarm signal inputs (S1, S2, S3) for enhanced system monitoring.
- Mana Putanga: Provides control outputs for key heat pump components including Water Pump, Fan, Valve, and Compressor.
- Hoahoa Roa: IP65 rated enclosure for protection against dust and water splashes.

Whakaahua 3.1: Mua view of the NA6888 controller display, showing the digital readout and control buttons.
4. Ihirangi mokete
I te whakatuwheratanga o te kete, me tirotiro kei roto i te kete nga waahanga katoa e whai ake nei:
- 1x NA6888 Regulator-Controller-Display Unit
- 1x Wiring Harness/Cables
- 2x Whakaekenga Topenga

Figure 4.1: Included wiring harness.

Figure 4.2: Mounting clips.
5. Tatūnga me te Tāuta
Installation of the NA6888 unit requires careful attention to electrical connections. It is strongly recommended that installation be performed by a qualified and licensed professional.
5.1. Whakapiki i te Waehe
- Identify a suitable location for the controller, ensuring it is protected from direct sunlight, extreme temperatures, and excessive vibration.
- Cut an appropriate opening in the mounting panel or enclosure, matching the dimensions of the NA6888 unit.
- Insert the NA6888 unit into the opening from the front.
- Secure the unit in place using the provided mounting clips on the sides, ensuring a snug fit.
5.2. Hononga Waea
Refer to the wiring diagram printed on the back of the NA6888 unit for precise connection points. Ensure all connections are secure and correctly polarized.

Figure 5.1: NA6888 Wiring Diagram.
Whakaahuatanga Kapeka:
| tauranga | Whakaahuatanga | Notes |
|---|---|---|
| T1 | Pūoko pāmahana | Connect the main temperature sensor (NTC=5kΩ/25°C). |
| T2 | Pūoko Whakakore | Connect the defrost sensor. |
| S1, S2, S3 | External Alarm Signals | Inputs for external alarm triggers. |
| 1, 2 | Whakauru Mana | Connect to 220V AC power supply. |
| 6, 7 | Water Pump Output | Control output for the water pump. |
| 8, 9 | Putanga Puawai | Control output for the fan. |
| 10, 11 | Huaputa takirere | Control output for the valve. |
| 11, 12 | Putanga Kōpeke | Control output for the compressor. Note shared terminal 11 with Valve. |
After all connections are made, double-check the wiring against the diagram to prevent damage to the unit or connected components.
6. Nga Tohutohu Whakahaere
Once installed and powered on, the NA6888 display will illuminate, showing current system parameters. The unit features several buttons for navigation and setting adjustments:
- Ki runga (^) Patene: Used to increase values or navigate up through menu options.
- Raro (v) Patene: Used to decrease values or navigate down through menu options.
- PATU Whakatakotoria: Used to enter a menu, confirm a selection, or save a setting.
- Pātene M (Tahua): Whakamahia hei uru atu ki te tahua matua, hei puta atu rānei i tētahi tahua-iti.
6.1. Mahi Taketake
- Whakahiko: Ensure the unit is correctly wired and power is supplied. The display will show the current temperature or system status.
- Viewi nga Tawhā: Use the Up/Down buttons to cycle through various displayed parameters (e.g., temperature readings from T1/T2, set points, operational status).
- Whakatika Tautuhinga:
- Pehia te SET button to enter the setting mode for the currently displayed parameter, or press the M pātene ki te uru ki te tahua matua.
- Whakamahia ngā pātene Runga/Raro hei whakarerekē i te uara.
- Perehi SET again to confirm and save the new value.
- Perehi M to exit the menu or setting mode.
For detailed programming and advanced settings, refer to the specific programming guide for your AstralPool heat pump model, as the NA6888 acts as the interface for these settings.
7. Tiaki
The NA6888 unit is designed for low maintenance. Regular checks can help ensure its longevity and proper function:
- Te horoi: Horoia te mata me te c i ia wāasing me te ngohengohe, damp kakahu. Kaua e whakamahia he horoi whakakoi, he whakarewa rānei. Kia tupato kei uru he wai ki roto i te waeine.
- Taki Hononga: Annually, or if issues arise, have a qualified technician check all electrical connections for tightness and signs of corrosion.
- Nga Tikanga Taiao: Ensure the unit remains within its specified operating environment (temperature, humidity) and that its IP65 rating is not compromised by physical damage.
8. Te Raru
If you encounter issues with your NA6888 unit, consider the following common troubleshooting steps. For complex problems, always consult a qualified technician.
| Raruraru | Take pea | Rongoā |
|---|---|---|
| He waatea te whakaaturanga | No power supply; Loose connection; Unit failure. | Check power source (220V AC). Verify wiring connections. If power is present and connections are secure, the unit may require replacement. |
| He he te panui pāmahana | Faulty sensor (T1 or T2); Loose sensor connection. | Check sensor wiring. Test sensor resistance (NTC=5kΩ/25°C). Replace sensor if faulty. |
| Outputs (Pump, Fan, etc.) not activating | Incorrect settings; Wiring issue; Component failure. | Verify controller settings. Check wiring to the respective component. Test the component itself. |
| External alarm not registering | Incorrect wiring to S1/S2/S3; Faulty external alarm device. | Check wiring to alarm inputs. Test the external alarm device. |
If troubleshooting steps do not resolve the issue, contact AstralPool customer support or a certified service technician. Information regarding spare parts availability is not provided.
9. Whakatakotoranga
| Tawhā | Uara |
|---|---|
| Tau tauira | NA6888 |
| Waitohu | AstralPool |
| Tuku Hiko | 220V AC, 2A te mōrahi |
| Te Whakamahana Pūoko Whakauru | T1 (NTC=5kΩ/25°C) |
| Defrost Sensor Input | T2 |
| Nga Whakauru Whakaoho o waho | S1, S2, S3 |
| Nga Putanga Mana | Water Pump, Fan, Valve, Compressor |
| Whakatauranga Tiaki | IP65 |
| Kāwai Tāuta | CAT II |
| ASIN | B07XGCN44T |
| Te Ra Wātea Tuatahi | 21 Pipiri 2021 |
10. Pūtāhui me te Tautoko
Specific warranty terms for the NA6888 unit are typically provided at the point of purchase or can be obtained directly from AstralPool. Please retain your proof of purchase for warranty claims.
For technical support, service, or inquiries regarding spare parts, please contact AstralPool customer service or your authorized dealer. Contact information can usually be found on the AstralPool official webpae, i runga ranei i to tuhinga hoko.