Vaillant 0010023777

Pukapuka Kaiwhakamahi mō te Whakamahana Wai Hiko Inamata a Vaillant VED E 18/8

Model: VED E 18/8 (0010023777)

1. Kupu Whakataki

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Vaillant VED E 18/8 Electronic Instantaneous Water Heater. Please read these instructions carefully before installation and use, and keep them for future reference.

The Vaillant electronicVED E 18/8 is designed to provide precise hot water comfort for single or multiple draw-off points, with a flow rate of 8 liters per minute. It is suitable for connection points with an 18 kW power supply.

Vaillant VED E 18/8 Electronic Instantaneous Water Heater front view

Whakaahua 1: Mua view of the Vaillant VED E 18/8 Electronic Instantaneous Water Heater.

2. Nga Tohutohu Haumaru

Hiranga: Installation of non-plug-in appliances must be carried out by a qualified professional or a registered specialist company. This ensures compliance with local regulations and safety standards. Failure to follow the warning and installation instructions in the provided manual can damage the product and void the warranty.

3. Tāutanga

3.1 Te Wetewete me te Tirotiro

Carefully unpack the water heater and inspect it for any damage. The package includes:

Screws and dowels are not included as they must be selected based on the specific mounting situation.

3.2 Te Tauwhi Maunga

The appliance is designed for vertical wall mounting. Ensure the chosen location complies with DIN 57100/VDE 100 protection zones (e.g., more than 60 cm from showers, bathtubs, sockets, or sinks). Under-sink installation may require additional accessories (article numbers 000479, 0020138088, 308086).

Vaillant VED E 18/8 installed in a bathroom

Whakaahua 2: Example installation of the water heater in a bathroom environment.

3.3 Hononga Hiko

The Vaillant VED E 18/8 requires a 400 V/50 Hz power supply. For the 18 kW model, a 5-wire connection cable with a cross-section of 6 mm² and a minimum three-phase protection of 32 amperes is required.

Technical requirements diagram for electrical connection

Figure 3: Technical requirements for electrical connection. For 18 kW, use 3 x 32 Ampere fuses and a 5 x 6 mm² cable.

3.4 Hononga Wai

Connect the cold water supply to the designated cold water inlet (R 1/2") and the hot water outlet to the hot water pipe (R 1/2"). Ensure all connections are sealed properly using the provided gaskets. The unit is compatible with all standard pressure-resistant water taps (two-handle mixer and single-lever mixer).

Close-up of water connections on the Vaillant VED E 18/8

Whakaatu 4: Taipitopito view of the cold and hot water connections at the bottom of the unit.

3.5 Te Komihana

Before the first use, the appliance must be thoroughly vented. Open the tap and let water flow until no more air escapes. Only then should the electrical connection be made. This prevents damage to the heating elements.

4. Nga Tohutohu Whakahaere

The Vaillant VED E 18/8 features a digital display for precise temperature control.

Digital display and control knob of the Vaillant VED E 18/8

Figure 5: Digital display showing temperature and control knob for adjustment.

4.1 Te Whakarereketanga o te Pawera

The desired hot water temperature can be continuously adjusted from 30 °C to 55 °C using the control knob on the front panel. The integrated digital display shows the set temperature.

4.2 Hot Water Flow

The unit provides a hot water flow rate of 8 liters per minute, allowing for simultaneous hot water supply to multiple points like a shower, sink, or bathtub.

5. Tiaki

The Vaillant VED E 18/8 is designed for easy maintenance with easily replaceable components. Regular inspection by a qualified professional is recommended to ensure optimal performance and longevity.

6. Te Raru

If you experience issues with your water heater, please consider the following:

For complex issues or repairs, contact a qualified Vaillant service technician. Do not attempt to repair the unit yourself, as this may lead to further damage or safety hazards.

7. Whakatakotoranga Hangarau

Below are the key technical specifications for the Vaillant VED E 18/8 Electronic Instantaneous Water Heater:

ĀhuahiraWhakatakotoranga
KaihangaWaillant
Tau tauira0010023777
Ahu (L x W x H)24 x 24 x 48.1 cm; 4.38 kg
Mana18 kW
Voltage400 V
Auautanga50 Hz
RauemiKirihou
Tikanga TāutaWhakapiki taiepa
Rere Rere8 liters per minute (hot water), 10 liters per minute (max)
Taumata Haruru15 dB
Momo WhakaatuLED
Momo TiakiIP25 (Jet-proof)
Fuse Rating (recommended)3 x 32 Amperes
Cable Cross-section (recommended)6 mm²
Karaehe Pungao PungaoA
Te Whakamahi Hiko ia Tau470 kWh
Energy efficiency label for Vaillant VED E 18/8

Figure 6: Energy efficiency label for the Vaillant VED E 18/8, showing Class A rating and 470 kWh annual consumption.

For detailed product information and compliance, refer to the EPREL database: https://eprel.ec.europa.eu/qr/1532813

8. Pūtāhui me te Tautoko

8.1 Nga Korero Whakaputanga

Specific warranty details are typically provided with your purchase documentation. Please retain your proof of purchase for warranty claims. For any warranty-related inquiries, contact your retailer or Vaillant customer service.

8.2 Tautoko Kiritaki

For technical assistance, spare parts, or service, please contact Vaillant customer support:

Tuhinga e pa ana - 0010023777

Preview Vaillant electronicVED: Pukapuka Tāutanga me te Whakahaere mō te Whakamahana Wai Hiko
This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the Vaillant electronicVED electric instantaneous water heater. It covers safety precautions, technical specifications, and contact information for Vaillant service.
Preview Vaillant electronicVED pro Installation and Operation Manual
Comprehensive guide for the Vaillant electronicVED pro instantaneous water heater, covering installation, operation, safety, maintenance, and troubleshooting. Includes technical specifications and model details.
Preview VAILLANT protočni bojler miniVED H 3/3 Uputstvo ki runga ki te montažu
Detaljno uputstvo za upotrebu i montažu protočnog bojlera VAILLANT miniVED H 3/3, sa specifikacijama, sigurnosnim uputstvima i savetima za održavanje. Saznajte kako pravilno instalirati i koristiti Vaillant bojler za efikasno grejanje vode.
Preview Vaillant aroSTOR VWL BM 200/5 & 270/5 Manual Tāuta me te Tiaki
He pukapuka ā-ringa whānui mō te tāutanga me te tiaki mō ngā whakamahana wai papu wera Vaillant aroSTOR VWL BM 200/5 me te VWL BM 270/5. Kei roto ko ngā tohutohu haumaru, te whakaahuatanga hua, ngā tikanga tāutanga, te whakatūnga, te whakahaere, te rapurongoā, te tiaki, ngā raraunga hangarau, me te whakakorenga.
Preview Vaillant ecoTEC me nga Tohutohu Whakahaere mo nga Kohua-Hua
Nga tohutohu whakahaere whai mana mo te Vaillant ecoTEC me nga raupapa o nga kohua-taiepa whakairi-a-hau. Ka kapi te haumarutanga, te whakaahuatanga hua, te mahi, te tiaki, te rapu raruraru, me nga korero whakamana.
Preview Vaillant sensoCOMFORT Basic Operating Instructions
A guide to the basic operating instructions for the Vaillant sensoCOMFORT heating control system, covering features like time programming, temperature override, and holiday mode.