Tektronix TBS2074B

Tektronix TBS2074B Digital Oscilloscope User Manual

Model: TBS2074B | Brand: Tektronix

1. Kupu Whakataki

The Tektronix TBS2000B series digital oscilloscopes are designed to provide high-level signal display and measurement, which are critical functions for any oscilloscope. The TBS2074B model, with its 70MHz bandwidth and 4 channels, offers an intuitive user experience and powerful analysis capabilities. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your TBS2074B oscilloscope.

Tektronix TBS2074B Digital Oscilloscope front view

Whakaahua 1.1: Mua view of the Tektronix TBS2074B Digital Oscilloscope.

2. Nga waahanga matua

The TBS2074B oscilloscope is equipped with features designed to enhance usability and measurement accuracy:

3. Tatūnga

3.1 Te Wetewete

Carefully remove the oscilloscope and all accessories from the packaging. Verify that all components listed in the packing list are present and undamaged. Retain the original packaging for future transport or storage.

3.2 Te Mana Hononga

Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable power outlet. Ensure the power source meets the voltage and frequency requirements specified on the device label.

Whakamuri view of Tektronix TBS2074B showing power input and connectivity ports

Figure 3.1: Rear panel of the oscilloscope with power input and connectivity ports.

3.3 Hiko Tuatahi

Press the power button located on the front panel. The oscilloscope will perform a self-test and then display the main waveform screen. Allow a few moments for the system to fully initialize.

4. Mahi

4.1 Atanga Kaiwhakamahi Nekeview

The TBS2074B features a large 9-inch display and an intuitive front panel with dedicated controls for vertical, horizontal, and trigger settings. Navigation buttons and a rotary knob allow for easy menu access and parameter adjustment.

Tektronix TBS2074B display showing 15 horizontal divisions

Figure 4.1: The oscilloscope display highlighting the 15 horizontal divisions for extended signal view.

4.2 Ngā Ine Taketake

To perform a basic measurement:

  1. Connect the appropriate probe to one of the input channels (CH1-CH4) on the front panel.
  2. Connect the probe tip to the circuit point you wish to measure.
  3. Adjust the vertical scale (Volts/Div) and horizontal scale (Sec/Div) knobs to display the waveform clearly.
  4. Use the Trigger controls to stabilize the waveform on the screen.
  5. Press the 'Measure' button to access automatic measurement options.
Tektronix TBS2074B with probes connected to input channels

Figure 4.2: Connecting probes to the oscilloscope input channels.

4.3 Nga Mahi Ake

The TBS2074B offers advanced analysis tools:

Tektronix TBS2074B display showing automatic measurement menu

Figure 4.3: The automatic measurement selection menu on the oscilloscope display.

Tektronix TBS2074B display showing waveform with search and mark function in use

Figure 4.4: Waveform display demonstrating the search and mark function.

5. Hononga

The TBS2074B offers various connectivity options for data transfer and remote control:

Close-up of the rear panel of Tektronix TBS2074B showing USB and Ethernet ports

Whakaahua 5.1: Whakatata view of the rear panel connectivity ports.

Tektronix TBS2074B connected to a laptop via USB cable

Figure 5.2: The oscilloscope connected to a laptop for data transfer or remote control.

6. Tiaki

6.1 Te horoi

To maintain the performance and appearance of your oscilloscope, regularly clean the exterior surfaces. Use a soft, damp cloth with a mild detergent. Avoid abrasive cleaners or solvents that could damage the plastic components or display.

6.2 Rokiroki

When not in use, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures. If storing for extended periods, it is recommended to use the original packaging or a protective case.

7. Te Raru

This section provides solutions to common issues you might encounter with your TBS2074B oscilloscope.

RaruraruTake peaRongoā
Karekau he kahaPower cord not connected; Power outlet fault; Internal fuse blownCheck power cord connection; Test power outlet; Contact service for fuse replacement
Kāore he āhua ngaru e whakaaturia anaProbe not connected; Incorrect vertical/horizontal settings; Trigger not set correctlyEnsure probe is connected; Adjust Volts/Div and Sec/Div; Adjust trigger level or mode
Ngaru kore pumauIncorrect trigger source or level; Signal noiseVerify trigger source and adjust trigger level; Use averaging or bandwidth limit to reduce noise

If you encounter issues not covered here, or if the suggested solutions do not resolve the problem, please contact Tektronix customer support.

8. Whakatakotoranga

Detailed technical specifications for the Tektronix TBS2074B Digital Oscilloscope:

WhakatakotorangaUara
KaihangaTektronix
Tau tauiraTBS2074B
Aratuku70 MHz (Upgradeable to 200 MHz with option)
Nga Waerenga Analog4
Max Sample Reiti2 GS/s (half channel), 1 GS/s (all channels)
Te roa o te tuhi5 M points
Whakaatu9-inch WVGA Color Display
Automatic Measurements32 momo
Atanga ProbeTekVPI
HonongaUSB 2.0 Host (front), USB 2.0 Device (rear), 10/100BASE-T Ethernet, Wi-Fi
Taumaha Tūemi3 Kirokaramu
Ahu mōkihi50 x 40 x 26 cm
Nga Waahanga kei rotoStandard Accessory KIT
Pikohiko WhakamahiaKao
Te Ra Wātea Tuatahi (Amazon.co.jp)2020/5/11

9. Pūtāhui me te Tautoko

Tektronix products are designed for reliability and performance. For information regarding warranty coverage, technical support, and service, please refer to the official Tektronix website or contact your local Tektronix representative. Keep your purchase receipt as proof of purchase for warranty claims.

For further assistance, visit the official Tektronix support page: www.tek.com/support

Tuhinga e pa ana - TBS2074B

Preview Tektronix 7 Series DPO Performance Oscilloscope DPO714AX Help Guide
Comprehensive help guide for the Tektronix 7 Series DPO Performance Oscilloscope, model DPO714AX. Learn about features, operation, configuration, and troubleshooting for this advanced test and measurement instrument.
Preview Tektronix 7L12 Te Tohutohu Tohutohu Kaitirotiro Tuorangi
This document provides comprehensive instructions for operating, testing, calibrating, and servicing the Tektronix 7L12 Spectrum Analyzer, a dual-width plug-in unit for 7000-Series Oscilloscopes. It details specifications, front panel controls, operational procedures, calibration methods, and applications for RF signal analysis.
Preview Tektronix 5 Raupapa B MSO: Ngā Whakatakotoranga me te Manatoko Mahi
Ngā whakaritenga taipitopito me ngā tikanga manatoko mahi mō ngā oscilloscopes Tektronix 5 Series B MSO, tae atu ki ngā tauira MS054B, MS056B, me MS058B. Ngā raraunga hangarau nui mō ngā kaihangarau me ngā tohunga hangarau.
Preview Tektronix 2235 Oscilloscope Service Manual
He pukapuka ratonga whanui mo te Tektronix 2235 Oscilloscope. Kei roto nga korero taipitopito, nga tohutohu whakahaere, te ariā o te mahi, nga arowhai mahi, nga tikanga whakatikatika, te tiaki, te rapu raru, me nga rarangi waahanga mo nga kaimahi ratonga whai mana.
Preview Tektronix 3 Series Mixed Domain Oscilloscope Help (MD032, MD034)
User guide for the Tektronix 3 Series Mixed Domain Oscilloscope (MD032, MD034), detailing features, operation, configuration, and troubleshooting for this advanced test and measurement instrument.
Preview Tektronix 3 Series MDO Oscilloscope MD032 & MD034: Specifications and Performance Verification
Detailed specifications and performance verification procedures for the Tektronix 3 Series Mixed Domain Oscilloscopes (MDO32 and MDO34), covering analog and digital channel performance, acquisition systems, trigger capabilities, and more.