The Mastervolt Alpha Pro III is an advanced charge regulator designed to optimize the charging process of your batteries. This device ensures efficient and safe power management for various applications, particularly in marine and mobile environments. It is engineered for reliability and ease of integration into existing power systems.
Key features include intelligent multi-stage charging, temperature compensation, and compatibility with 12V-24V systems. This manual provides detailed instructions for installation, operation, maintenance, and troubleshooting to ensure optimal performance and longevity of your Alpha Pro III.
Ka mutu te huaview

Figure 1: Mastervolt Alpha Pro III device. This image displays the compact, dark grey unit. Visible connections include a "TEMP SENSE" port (RJ45-like), a 4-pin connector, three spade terminals labeled "+BAT", "FIELD", and "GND", and two additional RJ45-like ports. The top surface features the "MASTERVOLT ALPHA PRO III" branding, a label indicating "Type: Alpha Pro III", "Input: 12V-24V-MB", and a serial number. Three small indicator lights are also visible on the top surface.
The Alpha Pro III unit is designed for robust performance. It features clearly labeled connection points for easy installation. The input voltage range is 12V to 24V, making it versatile for different battery bank configurations. Indicator lights provide quick status feedback during operation.
Tatūnga me te Tāuta
Proper installation is crucial for the safe and efficient operation of the Alpha Pro III. Always ensure the power supply is disconnected before making any connections.
- Whakapiki: Select a dry, well-ventilated location away from direct heat sources and flammable materials. Secure the unit using appropriate fasteners through the mounting holes.
- Hononga Pūoko Pawera: Connect the temperature sensor cable to the port labeled "TEMP SENSE". This sensor is vital for accurate temperature-compensated charging.
- Battery Connection (+BAT): Connect the positive battery cable to the terminal labeled "+BAT". Ensure a secure, low-resistance connection.
- Field Connection (FIELD): Connect the alternator field wire to the terminal labeled "FIELD". This connection allows the Alpha Pro III to control the alternator's output.
- Hononga Papa (GND): Connect the ground cable to the terminal labeled "GND". A solid ground connection is essential for safety and performance.
- Hononga Raraunga: Utilize the RJ45-like ports for communication with other Mastervolt devices or system monitoring, if applicable. Refer to your system's specific wiring diagram for these connections.
- Whakahiko: Once all connections are verified and secure, reconnect the battery power. Observe the indicator lights for initial status.
For detailed wiring diagrams and specific system configurations, please refer to the comprehensive installation guide available on the Mastervolt website or contact Mastervolt technical support.
Nga Tohutohu Whakahaere
The Alpha Pro III operates largely automatically once correctly installed. It continuously monitors battery voltage and temperature to optimize the charging profile.
- Mahi Aunoa: The unit will automatically begin charging when the engine is running and the alternator is producing power.
- Rama Tohu:
- LED Kakariki: Indicates normal operation and charging.
- LED kōwhai: May indicate a warning or specific charging stage. Consult the full manual for detailed interpretations.
- LED Whero: Indicates an error or fault condition. Immediate attention may be required.
- Ka utaina a Stage: The Alpha Pro III typically employs multi-stage charging (e.g., Bulk, Absorption, Float) to ensure batteries are charged efficiently and maintained optimally.
- Aroturuki Pūnaha: For advanced monitoring and configuration, connect the Alpha Pro III to a compatible Mastervolt system display or interface.
Te tiaki
The Mastervolt Alpha Pro III is designed for minimal maintenance. However, periodic checks can help ensure its long-term reliability.
- Tirotiro Ataata: Periodically inspect the unit and all connections for any signs of corrosion, loose wires, or physical damage.
- Te horoi: Keep the unit clean and free of dust and debris. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.
- Whakahau: Ensure that the area around the unit remains clear to allow for proper airflow and heat dissipation.
- Whakahōu Firmware: Tirohia te Mastervolt website periodically for any available firmware updates that may enhance performance or add new features.
Raparongoā
If you encounter issues with your Alpha Pro III, refer to the following common troubleshooting steps:
| Raruraru | Take pea | Rongoā |
|---|---|---|
| No charging output | Loose connections, blown fuse, alternator issue, or unit fault. | Check all wiring connections. Inspect system fuses. Verify alternator operation. If issues persist, contact support. |
| Rama Whero i tiaho | Neke atu i te-voltage, over-temperature, or internal fault. | Tirohia te puhiko voltage. Ensure adequate ventilation. Disconnect power, wait 5 minutes, and reconnect. If error persists, seek professional assistance. |
| Inaccurate charging | Faulty temperature sensor or incorrect battery settings. | Verify temperature sensor connection and integrity. Ensure battery type and capacity settings (if configurable) are correct. |
For more complex issues or if the problem cannot be resolved using these steps, please contact Mastervolt technical support.
Whakatakotoranga
| Huanga | Uara |
|---|---|
| Waitohu | Mastervolt |
| Ingoa Tauira | 45513000 |
| Nama Wahi | 45513000 |
| UPC | 816882020377 |
| Taumaha Tūemi | 2.38 Pauna |
| Rahi Tūemi (LxWxH) | 9.75 x 6.5 x 3 inihi |
| Rauemi | Kirihou |
| Tae | Kore Tae |
| Te Ra Tuatahi Wātea | Hōngongoi 9, 2020 |
| Kaihoko pai rawa atu | #33 in Photographic Lighting Power Packs |
Nga korero Whakaputanga
The Mastervolt Alpha Pro III comes with a manufacturer's warranty. For specific details regarding the warranty period, coverage, and terms, please refer to the official warranty documentation included with your product or visit the Mastervolt webpae. Pupurihia to tohu hoko mo nga kereme whakamana.
Tautoko me te Whakapā
For technical assistance, product inquiries, or warranty claims, please contact Mastervolt customer support. You can find contact information, including phone numbers and email addresses, on the official Mastervolt webpae.
Mastervolt Official Webpae: www.mastervolt.com
When contacting support, please have your product model number (45513000) and serial number (J824H 1002, if applicable) ready to expedite the process.