IBO BETA2 25-40/180

IBO BETA2 25-40/180 Hot Water Circulation Pump User Manual

1. Kupu Whakataki

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your IBO BETA2 25-40/180 Hot Water Circulation Pump. Please read this manual thoroughly before installation and retain it for future reference.

The IBO BETA2 25-40/180 circulation pump is a high-efficiency, durable, and reliable pump designed to circulate water in central heating systems, solar installations, or hot water systems. This device features 11 speed settings, allowing for parameter adaptation to various operating conditions. An electronic processor controls the pump's operation. It is equipped with a single-phase motor with a power range of 5 to 22 W. Constructed from high-quality materials, the IBO BETA2 pump ensures optimal performance under all conditions and is resistant to high temperatures. It can operate in ambient temperatures from 0 °C to 40 °C, with the device surface reaching approximately 125 °C and pumped water temperatures up to 110 °C. The pump is designed for easy installation and intuitive use, featuring an electronic display that shows current energy consumption and operating status. Additionally, the pump operates quietly (43 dB) and offers significant energy efficiency, consuming between 1/10 and 1/3 of the energy compared to traditional pumps. The device has a 1 ½ inch diameter connection (180 mm distance between connections). It operates with a capacity of up to 50 liters per minute and can lift water up to a height of 4 meters. The Beta 2 25-40/180 pump includes a power cable and screw fittings.

2. Nga Tohutohu Haumaru

Always observe the following safety precautions to prevent injury and damage to the pump or property:

  • Haumaru Hiko: Ensure the power supply matches the pump's specifications (230V). Disconnect power before any installation, maintenance, or repair work. All electrical connections must be performed by a qualified electrician and comply with local regulations.
  • Pāmahana Wai: The pump handles liquid temperatures from +2 °C to +110 °C. Ensure the system's operating temperature remains within this range.
  • Paemahana Ambient: Operate the pump in ambient temperatures between 0 °C and 40 °C.
  • Pēhanga: Do not exceed the maximum system pressure of 1 MPa.
  • Tāutatanga: Install the pump in a dry, well-ventilated area, protected from frost and direct sunlight. Ensure proper ventilation to prevent overheating.
  • Te whakahaere: The pump is heavy (2.92 kg). Use appropriate lifting techniques or assistance during installation.
  • Ngā Tamariki me ngā Kaimahi Kore Whakamana: Keep children and unauthorized persons away from the pump during operation and maintenance.

3. Nga Waahanga Nekeview

The IBO BETA2 25-40/180 circulation pump package typically includes the following items:

  • IBO BETA2 25-40/180 Circulation Pump Unit
  • Waea Hiko
  • Set of Screw Fittings (for pipe connection)
  • Pukapuka Kaiwhakamahi (tenei tuhinga)
IBO BETA2 25-40/180 Hot Water Circulation Pump with power cable

Whakaahua 3.1: IBO BETA2 25-40/180 Hot Water Circulation Pump. This image displays the IBO BETA2 25-40/180 hot water circulation pump. The pump is black, cylindrical in shape with two threaded pipe connections. An electronic display panel is visible on the front, showing 'ECO' and numerical readings, along with two green indicator lights and buttons labeled 'PP1', 'PP2', 'CP1', 'CP2'. A black power cable with a standard European plug is shown detached from the pump, indicating it's included for connection.

4. Tatūnga me te Tāuta

The IBO BETA2 25-40/180 pump is designed for easy installation. However, professional installation by a qualified technician is recommended to ensure proper functioning and compliance with all local codes and regulations.

4.1 Nga Tirohanga i mua i te whakaurunga

  • Verify that the installation site meets the ambient temperature requirements (0 °C to 40 °C).
  • Ensure the power supply is 230V and adequately protected.
  • Confirm that the pipe connections are clean and free of debris.

4.2 Te Whakapiki i te Puma

  1. Choose a suitable location in the heating or hot water system where the pump can be easily accessed for maintenance.
  2. Ensure the pump is mounted horizontally with the motor shaft in a horizontal position to ensure proper lubrication and cooling.
  3. Use the provided screw fittings to connect the pump to the system piping. Ensure a tight, leak-free connection. The connection diameter is 1 ½ inches, with a distance of 180 mm between connections.

4.3 Hononga Hiko

  1. Ensure the main power supply is switched off before making any electrical connections.
  2. Connect the provided power cable to the pump's electrical terminal block according to the wiring diagram (refer to the diagram on the pump or in the packaging if available).
  3. Connect the other end of the power cable to a grounded 230V power outlet.
  4. Manatokona kei te mau nga hononga katoa, kua tika te kiriweti.

4.4 System Filling and Venting

  1. After installation, fill the heating or hot water system with water.
  2. Vent the system thoroughly to remove any trapped air. Air in the system can cause noise, reduce pump efficiency, and lead to damage.

5. Nga Tohutohu Whakahaere

The IBO BETA2 25-40/180 pump features an electronic control system for intuitive operation.

5.1 Whakaoho Tuatahi

  1. After ensuring the system is filled and vented, switch on the main power supply to the pump.
  2. The electronic display will illuminate, showing the current operating status and energy consumption.

5.2 Te Whakatikatika i ngā Tautuhinga Tere

The pump offers 11 speed settings to adapt to various system requirements. Use the control buttons on the display panel (e.g., PP1, PP2, CP1, CP2, ECO) to cycle through the available modes and speeds. The display will indicate the selected setting and corresponding energy consumption.

  • Aratau ECO: For energy-efficient operation.
  • PP Modes: Proportional pressure modes, where pump head adjusts proportionally to flow rate.
  • CP Modes: Constant pressure modes, maintaining a constant differential pressure.

Consult your heating system's requirements or a qualified technician to determine the optimal setting for your application.

5.3 Monitoring Operation

The electronic display provides real-time feedback on:

  • Current energy consumption (in Watts)
  • Selected operating mode/speed
  • Any error codes (if applicable)

The pump operates quietly, with a sound pressure level of 43 dB.

6. Tiaki

Regular maintenance ensures the longevity and efficient operation of your IBO BETA2 25-40/180 pump.

6.1 General Checks (Monthly)

  • Visually inspect the pump for any signs of leaks, corrosion, or damage.
  • Listen for unusual noises during operation, which could indicate air in the system or mechanical issues.
  • Check the electronic display for any error messages.

6.2 System Water Quality

Maintain good water quality in your heating system. Poor water quality can lead to scale buildup, corrosion, and reduced pump performance. Consider using appropriate system inhibitors if recommended for your heating system type.

6.3 Te horoi

Keep the exterior of the pump clean and free from dust and debris to ensure proper heat dissipation.

6.4 Professional Servicing (Annually)

It is recommended to have the pump and heating system inspected by a qualified technician annually to ensure optimal performance and identify any potential issues early.

7. Te Raru

This section addresses common issues you might encounter with your IBO BETA2 25-40/180 pump. For complex problems, contact a qualified technician.

RaruraruTake peaRongoā
Kaore e timata te papuKarekau he hiko
I whakahiatohia / whati whati
Te aukati motuka
Check power connection and supply
Check and replace fuse/reset breaker
Disconnect power, check for obstructions in the impeller (professional service recommended)
Ka rere te papu engari karekau he tohanga waiTe hau i roto i te punaha
Marere kati
Te aukati impeller
Vent the system thoroughly
Open all necessary valves in the system
Disconnect power, check for obstructions (professional service recommended)
He haruru te papuTe hau i roto i te punaha
Cavitation (insufficient system pressure)
Whakamaunga wewete
Tukua te punaha
Check system pressure and increase if necessary
Ensure pump is securely mounted
Nga turuturu papuNga hononga matara
hiri kua pakaru
Tighten pipe connections
Contact a qualified technician for seal replacement
Electronic display shows error codeHapa ā-roto motuhakeRefer to the pump's specific error code list (if available in packaging) or contact technical support.

8. Whakatakotoranga Hangarau

TawhāUara
TauiraBETA2 25-40/180
KaihangaRöhtenbach
Te Mana Motini5 - 22 Uru
Voltage230 V (+6% / -10%)
Taumata HaumaruIP42
Akomanga Whakauru MotuhakeH
Teitei Hikinga Morahi4 mita
Rere Rere Morahi50 rita ia meneti
Haumākū Pātahi95%
Te Morahi Pēhanga Pūnaha1 MPa
Pumped Liquid Temperature+2 °C ki +110 °C
Te Paemahana Ambient0 °C ki te 40 °C
Taumata Pehenga Oro43 dB(A)
Diamita Hononga1 ½ inches (180 mm between connections)
Rahi Hua (L x W x H)21 x 18 x 11 cm
Taumaha Tūemi2.92 kg
RauemiMaka rino
TaePango
Momo Puna HikoTauera Hiko

9. Nga Korero Whakaputanga

Specific warranty details for the IBO BETA2 25-40/180 pump are not provided in the available product information. Please refer to your purchase documentation or contact your retailer for warranty terms and conditions.

10. Tautoko me te Whakapā

For technical assistance, spare parts, or service inquiries, please contact the retailer from whom you purchased the IBO BETA2 25-40/180 pump. Keep your purchase receipt and product model information readily available when contacting support.

Kaihanga: Röhtenbach

Tuhinga e pa ana - BETA2 25-40/180

Preview IBO MAGI 2 Energy-Saving Circulation Pump User Manual
This comprehensive user manual provides detailed information on the installation, operation, maintenance, and troubleshooting of the IBO MAGI 2 series of energy-saving circulation pumps. It includes technical specifications, performance curves, and safety guidelines for optimal use in domestic heating systems.
Preview IBO AMG & AMG SOLAR Circulation Pumps - User Manual
Comprehensive user and installation manual for IBO AMG and AMG SOLAR energy-efficient circulation pumps. Covers safety, installation, operation, technical specifications, troubleshooting, and EU declaration of conformity.
Preview IBO OHI / OHI MAX Circulation Pump Instruction Manual
Comprehensive instruction manual for IBO OHI and OHI MAX series circulation pumps, covering safety, installation, operation, technical specifications, and troubleshooting. Includes EC declaration of conformity and warranty information.
Preview Návod k použití: IBO AUTO IBO Povrchová čerpadla a Hydrofory
Kompletní návod k použití pro povrchová čerpadla a hydrofory IBO AUTO IBO. Obsahuje informace o instalaci, provozu, údržbě, řešení problémů a technické specifikace.
Preview IBF-02 Magnetic Separator - Operating Manual and Installation Guide
Comprehensive operating manual and installation guide for the IBO IBF-02 Magnetic Separator, detailing its features, technical specifications, installation procedures, maintenance, and safety precautions for central heating systems.
Preview Návod k obsluze čerpadel IBO AMG a AMG SOLAR
Podrobný návod k obsluze, instalaci a údržbě energeticky účinných oběhových čerpadel IBO řady AMG a AMG SOLAR. Zahrnuje technické specifikace, bezpečnostní pokyny a řešení problémů pro topné a solární systémy.