1. Kupu Whakataki
This manual provides detailed instructions for the safe and effective use of your KAIWEETS HT206B Clamp Meter and KAIWEETS KM100 Digital Multimeter. Please read this manual thoroughly before operation and retain it for future reference.
2. Nga korero haumaru
WARNING: Always observe safety precautions when working with electrical circuits to prevent personal injury or damage to the meter.
- The HT206B meets safety standard IEC 61010-1, CAT III 600V. The KM100 has passed CE and RoHS certifications and is IEC rated CAT III 600V.
- Both devices feature anti-burn protection with double fuses and overload protection on all ranges (KM100).
- Ensure the rotary switch is set to the correct test range before making measurements.
- Kaua e ngana ki te ine voltagngā iahiko rānei e neke ake ana i ngā rohenga mōrahi kua tohua.
- Tirohia ngā taura whakamātautau mō ngā pakaru i mua i ia whakamahinga. Kaua e whakamahia mēnā kua ngoikore te whakamarumaru.
- I te ine i te ia me te clamp meter, only clamp the live wire, not the entire power cord.
3. Hua Neke Atuview
3.1 KAIWEETS HT206B Clamp mita

Figure 1: KAIWEETS HT206B Clamp Meter and included accessories.
The KAIWEETS HT206B is a True-RMS clamp meter designed for accurate measurements on non-linear loads. It is suitable for various applications in labs, factories, and households.
Āhuatanga matua:
- Raukaha ine: AC Current, AC/DC Voltage, Frequency, Duty Cycle, Resistance, Capacitance, Diode, Continuity, and Temperature.
- Two-color Backlit LCD Display: The screen turns red to warn of high voltage (>80V) or high current (>3A).
- Maramarama arahina: For illumination in dimly lit areas.
- Kore-Whakapā Voltage (NCV) Rapunga: For detecting live wires without direct contact.
- Whakaweto Aunoa: Ka whakaweto i muri i te 15 meneti o te kore mahi hei penapena i te pākahiko.
- Tohu Pūhiko Iti: Whakatūpato ina hiahiatia he whakakapinga o ngā pākahiko.

Figure 2: HT206B Clamp Meter feature highlights.

Figure 3: NCV and Hold functions on the HT206B.
3.2 KAIWEETS KM100 Digital Multimeter

Figure 4: KAIWEETS KM100 Digital Multimeter and included accessories.
The KAIWEETS KM100 is a multi-function digital multimeter designed for safety and accuracy in various electrical tests, including household, automotive, and industrial applications.
Āhuatanga matua:
- Raukaha ine: AC / DC Voltage, DC Current, Resistance, Continuity, and Diode Measurement. Note: This model cannot test AC current.
- Mahi Whakamuri: Improves visibility in dark conditions.
- Pupuri Taumahi: Locks the displayed measurement value for easy recording.
- Support Stand: Flexible and stable, adjustable up to 90°.
- Haumaru: CAT III 600V, CE and RoHS certified, with anti-burn double fuses and overload protection.
4. Tatūnga
4.1 Tāuta Pūhiko
Both the HT206B and KM100 require AAA batteries for operation.
- Kimihia te uhi o te wahanga pākahiko kei muri o te taputapu.
- Whakamahia he tīwiri (mēnā e tika ana) hei whakatuwhera i te taupoki.
- Insert 2 AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment. (For KM100, batteries are typically pre-installed).
- Whakakapia te uhi o te wahanga pākahiko ka mau.
4.2 Connecting Test Leads and Thermocouple
For most measurements, test leads are required. For temperature measurements with the HT206B, the K-Type thermocouple is used.
- Insert the red test lead into the "VΩmA" or "+" input jack.
- Insert the black test lead into the "COM" or "-" input jack.
- For HT206B temperature measurement, connect the K-Type thermocouple to the designated temperature input ports, observing polarity.
5. Nga Tohutohu Whakahaere
5.1 Mahi Whanui
- Turn the rotary switch to the desired measurement function.
- Honoa ngā taura whakamātautau, te taura rāneiamp the conductor as appropriate for the measurement.
- Pānuihia te uara ine kei runga i te mata LCD.
- To turn off the device, rotate the switch to the "OFF" position. The HT206B also features automatic shutdown after 15 minutes of inactivity.
5.2 KAIWEETS HT206B Specific Operations
- Inenga AC Naianei: Rotate the switch to the AC Current range (e.g., 6/60A or 600A). Open the clamp jaw and enclose only the live wire of the circuit. Ensure the jaw is fully closed.
- Pātene FUNC.: Press the "FUNC." button to switch between secondary functions within a range, such as AC and DC voltage, or different frequency/duty cycle modes.
- NCV (Kore-Whakapā Voltage) Rapunga: Rotate the switch to the NCV position. Bring the top of the clamp meter near the conductor. The meter will beep and the NCV indicator will light up if AC voltagka kitea e.
- Taumahi HOLD: Press the "MAX/MIN" button briefly to activate the data hold function, freezing the current reading on the display. Press again to release.
- Ine inenga: Connect the K-Type thermocouple. Rotate the switch to the temperature function (°C/°F). Insert the thermocouple probe into the substance or area to be measured.

Figure 5: HT206B temperature measurement applications.
5.3 KAIWEETS KM100 Specific Operations
- Voltage Inenga (AC/DC): Rotate the switch to the desired AC V or DC V range. Connect test leads in parallel to the circuit.
- Inenga o naianei DC: Rotate the switch to the DC A range. Connect test leads in series with the circuit. Caution: Do not attempt to measure AC current with the KM100.
- Ine ātete: Rotate the switch to the Ω range. Connect test leads across the component to be measured. Ensure the circuit is de-energized.
- Whakamātautau Tonu: Rotate the switch to the continuity/diode position. Connect test leads across the circuit or component. A continuous beep indicates continuity.

Figure 6: KM100 Continuity Test.

Figure 7: KM100 DC Voltage Inenga.
6. Tiaki
6.1 Te horoi
Horoia te mita casing me te panuiamp kakahu me te hopi horoi ngawari. Kaua e whakamahia he mea whakakoi, he mea whakarewa rānei. Me whakarite kia maroke te mita i mua i te whakamahinga.
6.2 Whakakapinga Pūhiko
When the low battery indicator appears on the display, replace the batteries promptly to ensure accurate readings. Refer to Section 4.1 for battery installation instructions.
6.3 Rokiroki
When not in use for extended periods, remove the batteries to prevent leakage. Store the meters and accessories in their carrying cases in a cool, dry place, away from direct sunlight and extreme temperatures.

Figure 8: KM100 stored in its carrying case.
7. Te Raru
- Kāore he Whakaaturanga/Whakaaturanga Mārō: Check battery levels and replace if necessary. Ensure batteries are inserted with correct polarity.
- Pānui hē:
- Ensure the rotary switch is set to the correct measurement function and range.
- Verify test leads are properly connected and not damaged.
- Mo clamp meter, ensure the jaw is fully closed around a single conductor for current measurement.
- For resistance or continuity, ensure the circuit is de-energized.
- Meter Does Not Respond: Turn the meter off and then on again. If the issue persists, replace batteries.
8. Whakatakotoranga
8.1 KAIWEETS HT206B Clamp mita
| Inenga | Awhe | Tika |
|---|---|---|
| AC o nāianei | 6A/60A/600A | ±(2.5%+5) |
| AC Voltage | 6V/60V/600V | ±(1.0%+5) |
| DC Voltage | 600mV/6V/60V/600V | ±(0.5%+5) |
| Ātete | 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ | ±(1.0%+5) |
| Te kaha | 10nF/100nF/1μF/10μF/100μF/1mF/10mF/100mF | ±(4.0%+5) |
| Huringa Huringa / Mahi | 10Hz ki te 10MHz | ±(1.0%+3) |
| Te pāmahana | -4°F ki te 1832°F (-20°C ki te 1000°C) | ±(2.5%+5) |
| Kaute Whakaatu | 6000 Tatau | |
| Whakatauranga Haumaru | CAT III 600V, CE, RoHS, IEC 61010-1 | |
| Puna Mana | 2 x AAA Pūhiko | |
8.2 KAIWEETS KM100 Digital Multimeter
| Inenga | Awhe | Tika |
|---|---|---|
| AC Voltage | 20V/200V/600V | ±(1.0%+5) |
| DC Voltage | 200mV/2V/20V/200V/600V | ±(1.0%+5) |
| DC Naianei | 20mA/200mA/10A | ±(1.5%+5) |
| Ātete | 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ | ±(1.2%+5) |
| Whakatauranga Haumaru | CAT III 600V, CE, RoHS | |
| Puna Mana | 2 x Pūhiko AAA (kua tāuta-mua) | |
9. Pūtāhui me te Tautoko
KAIWEETS products are designed and manufactured to high-quality standards. Both the HT206B and KM100 are CE and RoHS certified, indicating compliance with European safety, health, and environmental protection requirements.
For specific warranty information or technical support, please refer to the warranty card included with your product or contact KAIWEETS customer service directly through their official channels.