Elitech SVP-7

Elitech SVP-7 7 CFM 2-Stage Smart Vacuum Pump Instruction Manual

Model: SVP-7 | Brand: Elitech

1. Nga korero haumaru

Please read and understand all safety warnings and instructions before operating the Elitech SVP-7 vacuum pump. Failure to follow these instructions may result in electric shock, fire, and/or serious injury.

2. Ihirangi mokete

Manatokona kei roto katoa nga mea kei roto i te kete:

Elitech SVP-7 Vacuum Pump and included accessories

Image: Elitech SVP-7 Vacuum Pump and its included accessories, such as vacuum oil and the user manual.

3. Nga Hua o te Hua

The Elitech SVP-7 Smart Vacuum Pump is designed with advanced features for efficient and reliable HVAC/R system evacuation:

Elitech SVP-7 Smart Vacuum Pump features overview

Whakaahua: Kua mutuview of the Elitech SVP-7's smart features, including touchscreen, app control, and leak detection.

4. Tatūnga

4.1 Initial Inspection and Oil Filling

  1. Unpack the vacuum pump and inspect for any shipping damage.
  2. Me whakarite kei te 'OFF' te whakakā hiko.
  3. Remove the oil fill cap and fill the pump with the provided vacuum oil until the oil level is between the 'MIN' and 'MAX' marks on the sight glass.
  4. Whakakapihia te potae whakakii hinu kia mau.

4.2 Connecting the Vacuum Gauge

For precise vacuum measurement, connect a compatible micron gauge to the pump or system:

Video: This video demonstrates the process of connecting a vacuum pump with a micron gauge for accurate readings during HVAC/R system evacuation.

4.3 Te Whakakaha

Connect the power cord to a suitable electrical outlet. Press the power switch to turn on the pump. The 4-inch touchscreen will illuminate, displaying the main interface.

Elitech SVP-7 Large Touch Screen Display

Image: The large touchscreen display of the Elitech SVP-7, showing real-time vacuum changes and operational data.

5. Nga Tohutohu Whakahaere

5.1 Mahi Taketake

  1. From the main screen, tap 'Measure' to view real-time vacuum data.
  2. Tap 'Run' to start the vacuum pump. The pump will begin evacuating the system.
  3. Monitor the vacuum level and other parameters on the touchscreen.
  4. Tap 'Stop' to halt the pump operation.

5.2 Mana Taupānga Pukoro

The Elitech SVP-7 can be controlled and monitored remotely via the Elitech Tools mobile app (iOS/Android):

  1. Download and install the 'Elitech Tools' app from your device's app store.
  2. Ensure Bluetooth is enabled on your mobile device and the vacuum pump.
  3. Open the app, search for the SVP-7, and connect.
  4. From the app, you can remotely start/stop the pump, monitor vacuum levels, and export PDF reports.
Elitech SVP-7 Real-time Monitoring Via APP

Image: A technician monitoring the Elitech SVP-7 via the mobile app on a rooftop HVAC unit.

Video: This video demonstrates the features and usage of the Elitech PGW Wireless Digital Pressure Gauge, including app connectivity and data management.

5.3 Smart Leak Detection System

The integrated leak detection system provides a risk scale (0-100) to identify potential leaks:

Elitech SVP-7 Detect System Leakage Level

Image: The Elitech SVP-7 touchscreen displaying the system leakage level and other operational statuses.

5.4 Real-Time Vacuum Graph

The touchscreen and app display a real-time vacuum graph, allowing visual monitoring of the evacuation process:

Elitech SVP-7 Intelligent and Simple Interface

Image: The Elitech SVP-7's intelligent and simple interface, highlighting the vacuum graph and other smart features.

5.5 Automated Operation

The pump features automated functions for convenience:

Elitech SVP-7 Automatic Switch on and off

Image: The Elitech SVP-7 operating automatically, allowing a technician to monitor progress remotely.

6. Tiaki

6.1 Te Whakawhiti Hinu

Regular oil changes are crucial for optimal pump performance and longevity. Change the vacuum pump oil after every 10-20 hours of operation or if the oil appears cloudy or discolored.

  1. Me mohio kua weto te papu me te momotu mai i te hiko.
  2. Whakatakotoria he ipu pai ki raro i te parai para hinu.
  3. Remove the oil drain plug and the oil fill cap to allow the old oil to drain completely.
  4. Whakakapihia te mono waikore hinu.
  5. Refill with new industrial-grade ISO 46 vacuum pump oil until the level is between the 'MIN' and 'MAX' marks on the sight glass.
  6. Whakakapihia te potae whakakii hinu.

6.2 Whakapai Whanui

Keep the pump clean and free from dust and debris. Wipe down the exterior with a damp kakahu. Kaua e whakamahia nga matū kino, nga whakarewa ranei.

6.3 Rokiroki

When not in use, store the vacuum pump in a dry, clean environment, protected from extreme temperatures and direct sunlight.

7. Te Raru

RaruraruTake peaRongoā
Kaore e timata te papuKāore he hiko, he pana hapa, he raruraru mō te motukaCheck power connection, ensure switch is ON. If problem persists, contact support.
He kino te mahi korehauLow oil level, contaminated oil, system leak, clogged intakeCheck/change oil, use leak detection system, inspect connections, clean intake.
Te wera o te papuInsufficient ventilation, prolonged operation, low oil levelEnsure adequate airflow, allow pump to cool, check oil level. Auto-shutdown will activate at 122°F.
Oil backflowMana outage during operation, faulty solenoid valveThe solenoid valve is designed to prevent this. If it occurs, check valve function and system integrity.

8. Whakatakotoranga

ĀhuahiraTaipitopito
WaitohuElitech
TauiraSVP-7
Rere Rere7 CFM (3 Liters Per Second)
Korehau Mutunga15 Micron
Stages2-Stage
Te Mana Motini3 / 4 HP
Puna ManaHiko Hiko
Taumaha Tūemi38.4 pauna
Hunga Hua20.47 x 16.93 x 14.96 inihi
WhakaatuMata pā 4"
HonongaBluetooth (Mobile App Control)
Nga waahanga haumaruSolenoid Valve, 122°F Auto-Shutdown
Elitech SVP-7 Vacuum Pump Specifications

Image: A detailed graphic outlining the technical specifications of the Elitech SVP-7 vacuum pump.

9. Pūtāhui me te Tautoko

Elitech products are designed for reliability and performance. This product comes with a standard manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included in your package or visit the official Elitech webpae.

For technical support, troubleshooting assistance, or service inquiries, please contact Elitech customer service through the contact information provided in your user manual or on the Elitech website. Our dedicated support team is available to assist you.

You can also find additional resources, FAQs, and product updates on the Elitech webpae: Toa Elitech