IBO S-150

IBO S-150 Central Heating Pump Controller User Manual

1. Hua Neke Atuview

The IBO S-150 is an electronic control unit designed for managing the circulation pump in a central heating system. Its primary function is to activate the pump when the water temperature exceeds a preset value and deactivate it when the temperature falls below that value. This intelligent control helps to optimize energy consumption and extend the operational lifespan of the pump.

Āhuatanga matua:

  • Integrated Thermostat Function: Allows setting specific temperature thresholds for pump activation and deactivation.
  • Mahi Ārai-Hukapapa: Automatically activates the pump if the ambient temperature drops below 5 °C (41 °F) to prevent freezing within the system.
  • Tiaki Pungao: Prevents unnecessary pump operation, leading to reduced energy consumption.
  • Extended Pump Lifespan: Reduces wear and tear on the pump by operating it only when required.
  • Tohu LED: Two LED displays show current temperature and set stop temperature.
  • Atanga ratarata-kaiwhakamahi: Simple button controls for setting parameters.

2. Nga korero haumaru

Pānuihia ngā tohutohu haumaru katoa i mua i te tāutanga me te whakahaere. Ki te kore e whai i ēnei tohutohu, ka pāngia pea koe e te ru hiko, te ahi, te whara kino rānei.

  • Haumaru Hiko: Installation and maintenance should only be performed by qualified personnel in accordance with local electrical codes and regulations.
  • Momotu Hiko: Always disconnect the power supply to the central heating system and the controller before performing any installation, wiring, or maintenance.
  • Te wai me te makuku: Do not expose the controller to water, excessive moisture, or extreme temperatures. Ensure the installation location is dry and protected.
  • Whakapapa Tika: Me whakarite kei te tika te hononga o te taputapu ki te whenua hei ārai i ngā tūponotanga hiko.
  • Tikanga taura: Regularly inspect all cables for damage. Do not use the device if any cables are frayed or damaged.
  • Whakamahinga Whakamahinga: Use the controller only for its intended purpose as a central heating pump controller.

3. Whakatakotoranga Hangarau

TawhāUara
Temperature Setting Range (Set Temperature)0 °C ki te 99 °C (32 °F ki te 210 °F)
Temperature Setting Range (Stop Temperature)0 °C ki te 99 °C (32 °F ki te 210 °F)
Te Paemahana Ambient-10 °C ki te 40 °C (14 °F ki te 104 °F)
Momo Pūoko Te pāmahanaAue
Taputapu Hiko Voltage230 V, 50 Hz, ±10%
Power Consumption (Controller Only)<5 W
Te Raro Taura RawaTata ki te 1 m (3.3 ft)
Te Roa Uera HikoTata ki te 1 m (3.3 ft)
Pump Power Cable LengthTata ki te 1 m (3.3 ft)
Putanga230V / 50Hz
Maximum Load (Pump)6 A (Resistive Load)
Whananga Inenga~0.1 °C
Rahi Hua (L x W x H)14 x 14 x 5 cm (5.5 x 5.5 x 2 inihi)
Taumaha370 karamu (0.82 lbs)

4. Tāuta me te Tatūnga

Before proceeding with installation, ensure the main power supply to your central heating system is turned off at the circuit breaker.

4.1. Te Whakamau i te Kaiwhakahaere

Select a suitable, dry location for mounting the controller, away from direct heat sources or excessive moisture. The controller can be mounted on a wall using appropriate fasteners (not included). Ensure sufficient space for cable connections.

4.2. Te hono i nga Tauera

The IBO S-150 controller comes with three main connections:

  1. Taputapu Tahana: This cable supplies power to the controller. Plug it into a standard 230V, 50Hz electrical outlet.
  2. Pump Power Cable: This cable connects the controller to your central heating circulation pump. Ensure the pump is compatible with the controller's specifications (Max load: 6A).
  3. Temperature Sensor Cable: The ohmic temperature sensor should be placed in a location where it can accurately measure the water temperature of the central heating system. Typically, this is on the return pipe or a designated sensor pocket. Ensure good thermal contact for accurate readings.
IBO S-150 Central Heating Pump Controller with all cables connected

Whakaatu 1: Neke Atuview of the IBO S-150 controller with its connected power, pump, and sensor cables.

Raro view of IBO S-150 controller showing power and pump sockets

Whakaahua 2: Raro view of the controller, illustrating the connection points for the power and pump cables.

After all connections are securely made, restore power to the central heating system.

5. Mahi

The IBO S-150 controller features a simple interface with two LED displays and three control buttons.

Front panel of IBO S-150 controller with LED displays and control buttons

Figure 3: Front panel of the IBO S-150 controller, showing the LED displays and control buttons.

5.1. Te Hia-Ai Tuatahi

Upon initial power-on, the upper LED display will show the current temperature measured by the sensor. The lower LED display will show the currently set 'stop temperature'.

5.2. Patene Mana

  • MENU Pātene: Used to cycle through and select different settings (stop temperature, start temperature, anti-freeze function). Pressing this button allows you to enter the setting mode for each parameter.
  • UP Arrow Button (▲): Used to increase the value of a selected parameter.
  • DOWN Arrow Button (▼): Used to decrease the value of a selected parameter.

5.3. Setting Temperature Parameters

  1. Pehia te MENU button to enter the setting mode. The lower display will start flashing, indicating you can adjust the 'stop temperature'.
  2. Whakamahia te UP (▲) a Raro (▼) arrow buttons to set the desired temperature at which the pump should stop.
  3. Pehia te MENU button again to confirm the 'stop temperature' and move to the 'start temperature' setting. The lower display will flash again.
  4. Whakamahia te UP (▲) a Raro (▼) arrow buttons to set the desired temperature at which the pump should start. This is typically a few degrees higher than the stop temperature to prevent rapid cycling.
  5. Pehia te MENU button a third time to confirm the 'start temperature' and exit the setting mode. The controller will return to displaying the current and stop temperatures.

5.4. Mahi Ārai-Huka

The anti-freeze function is automatically engaged. If the temperature measured by the sensor drops below 5 °C (41 °F), the pump will activate regardless of other settings to circulate water and prevent freezing. This function cannot be manually disabled.

6. Tiaki

The IBO S-150 controller requires minimal maintenance to ensure optimal performance and longevity.

  • Te horoi: Periodically wipe the exterior of the controller with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the device.
  • Tirohanga taura: Regularly check all connected cables (power, pump, sensor) for any signs of wear, damage, or loose connections. Replace damaged cables immediately.
  • Whakanohonga Pūoko: Ensure the temperature sensor remains securely in its intended position and maintains good thermal contact with the heating system pipe.
  • Nga Tikanga Taiao: Verify that the controller's operating environment remains within the specified ambient temperature and humidity ranges.

7. Te Raru

If you encounter issues with your IBO S-150 controller, refer to the following troubleshooting guide:

RaruraruTake peaRongoā
Karekau te mana whakahaere i te hiko.No power supply; loose power cable; faulty outlet.Check power outlet; ensure power cable is securely plugged in; check circuit breaker.
Pump does not turn on when temperature is high.Incorrect 'start temperature' setting; faulty pump connection; pump malfunction.Verify 'start temperature' setting; check pump power cable connection; test pump independently if possible.
Pump does not turn off when temperature is low.Incorrect 'stop temperature' setting; sensor malfunction.Verify 'stop temperature' setting; check sensor connection and placement.
He hē te panui o te pāmahana.Sensor improperly placed; faulty sensor.Ensure sensor has good thermal contact and is correctly positioned; replace sensor if necessary.
Anti-freeze function activates unexpectedly.Ambient temperature near or below 5 °C; sensor reading error.This is normal operation if ambient temperature is low. Check sensor reading for accuracy.

If the problem persists after attempting these solutions, please contact a qualified technician or the product support.

8. Pūtāhui me te Tautoko

Mō ngā mōhiohio pūtāhui me te tautoko hangarau, tirohia ngā tuhinga i whakaratohia me tō hoko, whakapā atu rānei ki tō kaihokohoko. Puritia tō taunakitanga hoko mō ngā kereme pūtāhui katoa.

Manufacturer: IBO

Model Number: S-150

Tuhinga e pa ana - S-150

Preview IBO IBF-01 Magnetic Filter with Ball Valve - User Manual and Technical Specifications
Comprehensive user manual and technical specifications for the IBO IBF-01 magnetic filter with ball valve. Learn about installation, operation, maintenance, safety precautions, and warranty.
Preview IBF-02 Magnetic Separator - Operating Manual and Installation Guide
Comprehensive operating manual and installation guide for the IBO IBF-02 Magnetic Separator, detailing its features, technical specifications, installation procedures, maintenance, and safety precautions for central heating systems.
Preview IBO IBF-09 Magnetic Dirt Separator User Manual
User manual for the IBO IBF-09 magnetic dirt separator, detailing installation, operation, maintenance, technical specifications, and warranty information for central heating systems.
Preview Návod k použití: IBO AUTO IBO Povrchová čerpadla a Hydrofory
Kompletní návod k použití pro povrchová čerpadla a hydrofory IBO AUTO IBO. Obsahuje informace o instalaci, provozu, údržbě, řešení problémů a technické specifikace.
Preview IBO SOLAR Pressure Vessels - Instruction Manual
Comprehensive instruction manual for IBO SOLAR diaphragm pressure vessels, covering installation, operation, maintenance, technical specifications, and safety guidelines for solar and hot water systems.
Preview Instrukcja obsługi pompy zatapialnej IBO DRAIN 400
Szczegółowa instrukcja obsługi dla pompy zatapialnej IBO DRAIN 400. Zawiera informacje o instalacji, bezpiecznym użytkowaniu, konserwacji i rozwiązywaniu problemów.