ERICKHILL ROOK600C

ERICKHILL Infrared Thermometer Gun User Manual

Model: ROOK600C

1. Kupu Whakataki

The ERICKHILL Infrared Thermometer Gun is a non-contact temperature measurement device designed for various applications, including cooking, BBQ, HVAC, engine diagnostics, and pool temperature monitoring. It provides rapid and accurate temperature readings from -58°F to 1112°F (-50°C to 600°C) with a ±1.5% accuracy. Featuring adjustable emissivity and a 12:1 distance-to-spot ratio, this thermometer allows for precise measurements from a safe distance. Its user-friendly design includes a clear backlit LCD, laser targeting, and automatic shut-off for power saving.

ERICKHILL Infrared Thermometer Gun with two AAA batteries

Figure 1.1: ERICKHILL Infrared Thermometer Gun and included AAA batteries.

2. Nga korero haumaru

WARNING: This device is NOT intended for measuring human or animal body temperature. It is designed for industrial and household surface temperature measurements only.

Infrared thermometer pointing at a person's forehead with a red X indicating it's not for human use.

Figure 2.1: The thermometer is not for human temperature measurement.

3. Hua Neke Atuview

3.1 Ihirangi mokete

3.2 Waenga Pūrere

Diagram of the infrared thermometer's LCD display showing various indicators like hold, scan, emissivity, Fahrenheit/Centigrade, measurement reading, backlight, laser, and low battery indicator.

Figure 3.1: LCD Display and Component Overview.

4. Tatūnga

4.1 Tāuta Pūhiko

The ERICKHILL Infrared Thermometer requires two AAA batteries (included). To install or replace batteries:

  1. Locate the battery compartment on the handle of the device.
  2. Whakatuwheratia te uhi o te wahanga pākahiko.
  3. Whakauruhia nga pākahiko AAA e rua, kia tika te polarity (+/-).
  4. Katia kia mau te uhi o te wahanga pākahiko.
Image showing the battery compartment of the ERICKHILL Infrared Thermometer and two AAA batteries being inserted.

Pikitia 4.1: Te tāutanga pākahiko.

5. Nga Tohutohu Whakahaere

5.1 Ine Taketake

Hei tango i te panui pāmahana:

  1. Whakatakotoria te inemahana ki te mata o te ūnga.
  2. Press and hold the measurement trigger. The laser pointer will activate (if enabled) to indicate the measurement spot.
  3. The temperature reading will appear on the LCD display within 0.5 seconds.
  4. Release the trigger to hold the reading on the display. The device will automatically shut off after 12 seconds of inactivity.
Icon indicating 0.5 second rapid response time.Icon indicating data hold function.

Figure 5.1: Fast response and data hold features.

5.2 Adjustable Emissivity

Emissivity is the ability of a material to emit thermal energy. Different materials have different emissivity values. Adjusting the emissivity setting (EMS) on the thermometer ensures more accurate readings for various surfaces. The default value is 0.95, suitable for most organic materials and painted surfaces. You can adjust it from 0.1 to 1.0.

  1. With the device on, press the 'MODE' button. The 'EMS' indicator will appear on the display.
  2. Use the Up/Down buttons to adjust the emissivity value.
  3. Press the 'MODE' button again to confirm the setting or wait for the device to return to measurement mode automatically.
Emissivity table showing different materials and their corresponding emissivity values, such as Aluminum 0.30, Iron 0.70, Wood 0.94, etc.

Figure 5.2: Emissivity Table for common materials.

5.3 Unit Switching (°C/°F)

Hei whakawhiti i waenga i te Celsius (°C) me te Fahrenheit (°F):

Close-up of the thermometer's display and buttons, highlighting the C/F switch button.

Figure 5.3: °C/°F unit switch button.

5.4 Backlight and Laser Control

The device features a backlight for visibility in low-light conditions and a laser pointer for precise targeting.

Close-up of the thermometer's display and buttons, highlighting the backlight and laser toggle buttons.

Figure 5.4: Backlight and Laser control buttons.

5.5 Whakaweto Aunoa

To conserve battery life, the thermometer will automatically shut down after 12 seconds of inactivity.

6. Nga tono

The ERICKHILL Infrared Thermometer Gun is suitable for a wide range of non-contact temperature measurement tasks, including but not limited to:

Collage of images showing the infrared thermometer being used in various applications: checking engine temperature, HVAC, pizza oven, BBQ, and soldering.

Figure 6.1: Wide range of applications for the thermometer.

7. Tiaki

To ensure the longevity and accuracy of your ERICKHILL Infrared Thermometer:

8. Te Raru

9. Whakatakotoranga

ĀhuahiraWhakatakotoranga
Awhe Pawera-58 ° F ~ 1112 ° F (-50 ° C ~ 600 ° C)
Tika±1.5%
Wā Whakautu0.5 hēkona
Ōwehenga Tawhiti-ki-Wāhi (D:S)12:1
HarikiriAdjustable (0.1-1.0), default 0.95
Puna Mana2 x AAA Battery (kei roto)
Whakaweto Aunoa12 hēkona o te kore mahi
Momo WhakaatuLCD Mamati me te Marama Whakamuri
Āhuahira MotuhakeNon-Contact Measurement, Laser Pointer
Hunga Hua8.11 x 7.76 x 1.81 inihi
Taumaha Tūemi6 hekere
Tau tauiraROOK600C

10. Pūtāhui me te Tautoko

ERICKHILL provides a 3-year warranty and lifetime technical support for each product. If you have any questions or require assistance with your ERICKHILL Infrared Thermometer Gun, please do not hesitate to contact ERICKHILL customer service.

Tuhinga e pa ana - ROOK600C

Preview ERICKHILL ROOK 400/600 SP IR Thermometer Manual Kaiwhakamahi
He pukapuka whakamahi mo te ERICKHILL ROOK 400 SP me te ROOK 600 SP nga inemahota infrared. Ka whakarato i nga tohutohu mo te mahi, nga ahuatanga, te haumaru, me nga whakaritenga hangarau.
Preview ERICKHILL ER02 EMF Meter Manual Kaiwhakamahi
Tirohia nga kaha o te ERICKHILL ER02 EMF Meter me tenei pukapuka kaiwhakamahi matawhānui. Akohia mo tana mahinga 3-i-1 mo te ine i nga mara hiko, autō, me te reo irirangi, tae atu ki te mahi, nga whakaritenga, me nga aratohu haumaru.
Preview Erickhill RT-100S EMF Meter Manual Kaiwhakamahi
Te pukapuka a te kaiwhakamahi mo te Erickhill RT-100S EMF Meter, e whakaatu ana i ona ahuatanga, mahi, tohu hangarau, me nga tono mo te ine i nga mara hiko, hiko, me te RF.