1. Kupu Whakataki
The ERICKHILL Infrared Thermometer Gun is a non-contact temperature measurement device designed for various applications, including cooking, BBQ, HVAC, engine diagnostics, and pool temperature monitoring. It provides rapid and accurate temperature readings from -58°F to 1112°F (-50°C to 600°C) with a ±1.5% accuracy. Featuring adjustable emissivity and a 12:1 distance-to-spot ratio, this thermometer allows for precise measurements from a safe distance. Its user-friendly design includes a clear backlit LCD, laser targeting, and automatic shut-off for power saving.

Figure 1.1: ERICKHILL Infrared Thermometer Gun and included AAA batteries.
2. Nga korero haumaru
WARNING: This device is NOT intended for measuring human or animal body temperature. It is designed for industrial and household surface temperature measurements only.

Figure 2.1: The thermometer is not for human temperature measurement.
- Do not point the laser directly into eyes or at reflective surfaces.
- Tiakina te taputapu mai i nga tamariki.
- Do not use the device in explosive gas, vapor, or dust environments.
- A ape i te tuku i te taputapu ki nga wera nui, makuku ranei.
3. Hua Neke Atuview
3.1 Ihirangi mokete
- 1 x ERICKHILL Infrared Thermometer
- 1 x Pukapuka Kaiwhakamahi
- 2 x AAA Pūhiko
3.2 Waenga Pūrere

Figure 3.1: LCD Display and Component Overview.
- Pūwhakaoho Ine: Press to activate and take readings.
- Whakaaturanga LCD: Shows temperature readings, mode indicators, and battery status.
- Tohu Taiaho: Helps pinpoint the measurement target.
- Patene °C/°F: Toggles between Celsius and Fahrenheit units.
- Pātene MODE: Used to adjust emissivity.
- Pihi Whakatika / Raro: Adjust emissivity value in MODE.
4. Tatūnga
4.1 Tāuta Pūhiko
The ERICKHILL Infrared Thermometer requires two AAA batteries (included). To install or replace batteries:
- Locate the battery compartment on the handle of the device.
- Whakatuwheratia te uhi o te wahanga pākahiko.
- Whakauruhia nga pākahiko AAA e rua, kia tika te polarity (+/-).
- Katia kia mau te uhi o te wahanga pākahiko.

Pikitia 4.1: Te tāutanga pākahiko.
5. Nga Tohutohu Whakahaere
5.1 Ine Taketake
Hei tango i te panui pāmahana:
- Whakatakotoria te inemahana ki te mata o te ūnga.
- Press and hold the measurement trigger. The laser pointer will activate (if enabled) to indicate the measurement spot.
- The temperature reading will appear on the LCD display within 0.5 seconds.
- Release the trigger to hold the reading on the display. The device will automatically shut off after 12 seconds of inactivity.


Figure 5.1: Fast response and data hold features.
5.2 Adjustable Emissivity
Emissivity is the ability of a material to emit thermal energy. Different materials have different emissivity values. Adjusting the emissivity setting (EMS) on the thermometer ensures more accurate readings for various surfaces. The default value is 0.95, suitable for most organic materials and painted surfaces. You can adjust it from 0.1 to 1.0.
- With the device on, press the 'MODE' button. The 'EMS' indicator will appear on the display.
- Use the Up/Down buttons to adjust the emissivity value.
- Press the 'MODE' button again to confirm the setting or wait for the device to return to measurement mode automatically.

Figure 5.2: Emissivity Table for common materials.
5.3 Unit Switching (°C/°F)
Hei whakawhiti i waenga i te Celsius (°C) me te Fahrenheit (°F):
- Press the '°C/°F' button located below the display. The unit will change instantly.

Figure 5.3: °C/°F unit switch button.
5.4 Backlight and Laser Control
The device features a backlight for visibility in low-light conditions and a laser pointer for precise targeting.
- To toggle the backlight, press the button with the light bulb icon.
- To toggle the laser pointer, press the button with the laser icon.

Figure 5.4: Backlight and Laser control buttons.
5.5 Whakaweto Aunoa
To conserve battery life, the thermometer will automatically shut down after 12 seconds of inactivity.
6. Nga tono
The ERICKHILL Infrared Thermometer Gun is suitable for a wide range of non-contact temperature measurement tasks, including but not limited to:
- Te tunu me te tunu: Checking temperatures of ovens, grills, griddles, pizza stones, and cooking surfaces.
- HVAC: Monitoring air conditioning vents, heating systems, and insulation efficiency.
- Automotive: Measuring engine components, tires, and brake temperatures.
- Home Maintenance: Identifying hot or cold spots in walls, windows, and pipes.
- Pool and Spa: Checking water temperatures.
- Whakamahi Ahumahi: Monitoring machinery, electrical panels, and manufacturing processes.

Figure 6.1: Wide range of applications for the thermometer.
7. Tiaki
To ensure the longevity and accuracy of your ERICKHILL Infrared Thermometer:
- Te horoi: Horoia te taputapu ki te ngohengohe, damp kakahu. Kaua e whakamahi i nga taputapu horoi, kaua e rukuhia te taputapu ki te wai.
- Rokiroki: Store the device in a cool, dry place when not in use. Remove batteries if storing for extended periods to prevent leakage.
- Tiaki Mata: The infrared lens is the most delicate part. Clean it gently with a soft cloth or cotton swab and rubbing alcohol if necessary.
8. Te Raru
- Kaore te taputapu e ka ana:
- Tirohia mehemea kei te tika te whakauru o nga pākahiko me te polarity tika.
- Whakakapihia ki nga pākahiko AAA hou.
- Ko nga panui kore tika:
- Ensure the emissivity setting is appropriate for the material being measured (refer to Section 5.2).
- Check that the lens is clean and free from dust or debris.
- Ensure the distance-to-spot ratio is respected; avoid measuring objects too close or too far.
- Avoid measuring through transparent surfaces like glass, as they can lead to inaccurate readings.
- Kaore e mahi ana a Laser:
- Ensure the laser function is enabled (refer to Section 5.4).
- Tirohia te taumata pākahiko.
9. Whakatakotoranga
| Āhuahira | Whakatakotoranga |
|---|---|
| Awhe Pawera | -58 ° F ~ 1112 ° F (-50 ° C ~ 600 ° C) |
| Tika | ±1.5% |
| Wā Whakautu | 0.5 hēkona |
| Ōwehenga Tawhiti-ki-Wāhi (D:S) | 12:1 |
| Harikiri | Adjustable (0.1-1.0), default 0.95 |
| Puna Mana | 2 x AAA Battery (kei roto) |
| Whakaweto Aunoa | 12 hēkona o te kore mahi |
| Momo Whakaatu | LCD Mamati me te Marama Whakamuri |
| Āhuahira Motuhake | Non-Contact Measurement, Laser Pointer |
| Hunga Hua | 8.11 x 7.76 x 1.81 inihi |
| Taumaha Tūemi | 6 hekere |
| Tau tauira | ROOK600C |
10. Pūtāhui me te Tautoko
ERICKHILL provides a 3-year warranty and lifetime technical support for each product. If you have any questions or require assistance with your ERICKHILL Infrared Thermometer Gun, please do not hesitate to contact ERICKHILL customer service.


