Kupu Whakataki
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Reznor UDXC-45 Natural Gas Unit Heater. Please read this manual thoroughly before installation or use and retain it for future reference. This unit is designed for indoor use in commercial, industrial, or residential spaces such as garages, workshops, and warehouses.
Nga korero haumaru
WHAKATŪPATO: Ko te whakaurunga, te whakatikatika, te whakarereketanga, te ratonga, te tiaki ranei ka taea te kino o nga rawa, te whara, te mate ranei. Pānuihia nga tohutohu whakaurunga, whakahaere me te tiaki i mua i te whakauru, te mahi ranei i enei taputapu.
- Installation must comply with local and state codes. It is highly recommended that installation and service be performed by a qualified installer, service agency, or gas supplier.
- Me whakarite kia pai te hau i roto i te waahi whakauru.
- Kaua e penapena, e whakamahi ranei i te penehīni, i etahi atu kohu me nga wai e mura ana ki te taha tata o tenei taputapu ranei.
- Ka taea e tenei hua te whakaatu ki a koe i nga matū tae atu ki te tima me te raima mata, e mohiotia ana e te Kawanatanga o California kia pa mai te mate pukupuku me nga whanautanga whanau, me etahi atu mea kino ki te whanau ranei. Mo etahi atu korero haere ki www.P65Warnings.ca.gov.
Nga waahanga hua
- Raukaha Whakawera: 45,000 BTU with two heating output levels (low fire 26,145 BTU / high fire 37,350 BTU).
- Putanga Weariki: E 83% te whakatauranga pai o te whakamahinga wera.
- Te Kaitohu Panui: TCORE2 titanium-stabilized aluminized steel heat exchanger for durability.
- Te tahunga: Patented single-burner combustion system.
- Pūnaha Mana: Integrated circuit board with a 7-segment display for simple troubleshooting, built-in disconnect, and status-indicating LED.
- Fan System: Quiet operation with a vibration/noise isolated low static pressure axial propeller fan and power venting system.
- Whakapiki: He pupuri nati miro kei ngā pūwāhi whakatārewatanga e whā mō te whakairi i te tuanui, i te pakitara rānei (ka hokona motuhake ngā taputapu whakairi).
- Hoahoa: Improved cabinet design with a removable front face and a hinged access door panel with a quarter-turn latch.
- Tiwhikete: ETL Approved. All UDXC sizes are certified for Commercial/Industrial Use. 30K-120K BTU units also approved for Residential Garages & Workshops.

Figure 1: Key features of the Reznor UDXC-45 Unit Heater, highlighting 83% AFUE Efficiency, Multi-Try Direct Spark Ignition, TCORE2 Heat Exchanger, and Low Noise Operation.

Figure 2: Additional standard features including Status-Indicating LED Light, 7-Segment Display Board for Troubleshooting, 2- and 4-Point Suspension Options, External Gas Connection, and ETL Approval.
Tatūnga me te Tāuta
Proper installation is crucial for the safe and efficient operation of your Reznor UDXC-45 heater. It is strongly recommended that installation be performed by a certified HVAC professional or gas technician.
Whakaeke
- The unit is designed for ceiling or wall mounting. It includes threaded-nut retainers at four suspension points.
- Mounting brackets and hardware are sold separately and must be appropriate for the unit's weight and the structural integrity of the mounting surface.
- Ensure the unit is installed in a location that allows for proper air circulation and access for maintenance.
Te hoko
- The unit is compatible with Category 1 double wall B-vent when venting vertically out of a roof.
- Alternatively, it can be vented horizontally through a sidewall using Category 3 single wall vent pipe.
- Me tutuki ngā whakaurunga hau katoa i ngā ture hanga ā-rohe me ngā whakaritenga a te kaihanga.

Whakaatu 3: Neke Atuview of simplified installation features, including updated cabinet structure, hinged access panel, and suspension points for mounting.
Nga Tohutohu Whakahaere
The Reznor UDXC-45 heater is designed for user-friendly operation. Ensure all gas and electrical connections are securely made and checked by a professional before initial startup.
Tīmatahia te Whakawera
- Verify that the gas supply valve to the unit is open.
- Ensure the electrical power to the unit is turned on.
- Set your thermostat to the desired temperature. The unit will automatically cycle on and off to maintain the set temperature.
Heating Output Levels
The UDXC-45 features two heating output levels for optimal efficiency:
- Low Fire (26,145 BTU): Suitable for milder cool days, providing efficient heating without excessive energy consumption.
- High Fire (37,350 BTU): Engages for colder temperatures, ensuring rapid and effective heating of the space.
Mahi Ata
The unit operates quietly due to its vibration/noise isolated low static pressure axial propeller fan and power venting system. This design minimizes operational noise, making it suitable for environments where sound levels are a consideration.

Figure 4: The Reznor UDXC shop heater's single-burner design offers two BTU outputs for efficient heating in any weather.

Figure 5: The low static pressure axial fan and power venting system ensure optimal air circulation and reduce heat loss.
Video Demonstration: Quiet Operation
This video demonstrates the quiet operation of the Reznor UDXC-45 heater, showcasing the minimal noise produced by the fan during operation. This is particularly useful for environments like workshops or garages where noise levels are a concern.
Video: Hear the quiet operation of the Reznor UDXC-45 heater.
Te tiaki
Regular maintenance ensures the longevity and optimal performance of your Reznor UDXC-45 heater. It is recommended that all maintenance be performed by a qualified service technician.
- Tirohanga Tau: Have the unit inspected annually by a qualified technician to check for proper operation, gas connections, venting, and overall condition.
- Te horoi: Keep the area around the heater clear of obstructions and debris. Periodically clean the exterior of the unit.
- Te Kaitohu Panui: The TCORE2 titanium-stabilized aluminized steel heat exchanger is built for durability, but regular checks for any signs of wear or damage are advisable during professional inspections.
- Uru: The improved cabinet design with a removable front face and a hinged access door panel with a quarter-turn latch simplifies access for maintenance.
Raparongoā
If your Reznor UDXC-45 heater is not operating as expected, refer to the following general troubleshooting steps. For complex issues, always contact a qualified service technician.
- Kāore he Wera/Kāore te Wāhanga e Tīmata:
- Check if the gas supply valve is open.
- Verify that the electrical power to the unit is on.
- Ensure the thermostat is set to a temperature higher than the ambient room temperature.
- Check the status-indicating LED and the 7-segment display board for error codes, which can assist in diagnosing the issue.
- Haruru rerekee:
- Me whakarite kia mau te whakaurunga o te waeine me te kore e wiri.
- Contact a technician if unusual noises persist, as it may indicate an issue with the fan or other internal components.
- He iti rawa te whakawera:
- Confirm the unit is operating on the appropriate fire level for the ambient temperature.
- Tirohia mēnā he ārai kei roto i ngā pūhau whakauru hau, ngā pūhau whakaputa hau rānei.
Whakatakotoranga
| Huanga | Uara |
|---|---|
| Waitohu | Reznor (1HVAC) |
| Tau tauira | UDXC-45 |
| Momo wahie | Hau Maori |
| Heat Output (High Fire) | 37,350 Nga Waahanga Ngawha o Ingarangi |
| Heat Output (Low Fire) | 26,145 Nga Waahanga Ngawha o Ingarangi |
| Te Manawaariki | 83% |
| Mahinga o roto/waho | Roo-roto |
| Momo Whakaeke | Ceiling Mount / Wall Mount (with separate brackets) |
| Hunga Hua | 29.75"D x 27"W x 13.75"H |
| Taumaha Tūemi | 60.9 pauna |
| Te maha o nga tere | 2 |
| Āhuahira Motuhake | Fast Heating, Quiet Operation |

Figure 6: Physical dimensions of the 45,000 BTU Reznor unit heater.
Pūtāhui me te Tautoko
Te Rarangi Rarangi
The Reznor UDXC-45 heater comes with the following warranty coverage:
- 9 Tau Pūtāhui: Heat Exchanger, Burner, and Flue Collection Box Assembly.
- 4 Tau Pūtāhui: All Electrical and Mechanical Components.
To ensure a valid warranty, installation must comply with all local and state codes.
Tautoko Kiritaki
For technical assistance, warranty claims, or service inquiries, please contact the manufacturer's authorized service center or your original point of purchase. Always provide your model number (UDXC-45) and serial number when contacting support.