1. Kupu Whakataki
This manual provides comprehensive instructions for the installation, operation, and maintenance of your MARSTEK Smart Circuit Breaker HF-00095. This device offers adjustable overvoltage, whakahekeheketage, and overcurrent protection, along with energy monitoring capabilities, to safeguard your electrical equipment.
2. Nga Korero Haumaru Nui
Please read and understand all safety instructions before installing or operating the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ko te whakaurunga me mahi e tetahi tohunga hiko anake.
- Ensure all power to the circuit is disconnected at the main breaker before installation or maintenance.
- Kaua e whakahaeretia te taputapu ki te ahua kua pakaru.
- Kia mau ki nga waehere hiko katoa o te rohe me nga ture.
- This device is designed for AC circuits within specified voltage me nga awhe o naianei.
3. Hua Neke Atuview me nga ahuatanga
The MARSTEK Smart Circuit Breaker HF-00095 is designed to provide intelligent protection and monitoring for your electrical circuits. It features a digital display for real-time voltage and current, and allows for customizable protection settings.

- Wā-tūturu Voltage Whakaatu: Ka whakaatu i te voltage.
- Real-Time Current Display: Ka whakaatu i te o naianei ampwhakatipu
- Work Indicator Lights: Indicate operational status and protection events.
- PATU Whakatakotoria: Long press to enter settings mode.
- Kī Runga me Raro: Used to adjust overvoltage, whakahekeheketage, and overcurrent values.
- Manual Power Off Button: Allows for manual disconnection of the circuit.
Ko nga ahuatanga matua ko:
- Tailored Protection: Customize overvoltage, whakahekeheketage, and overcurrent values to suit specific requirements.
- Tautuhinga Taunoa: Pre-set values for convenience - Overvoltage Trip at 140V, Undervoltage Trip at 90V, and Overcurrent Trip at 63A.
- Intelligent Recovery: After power events, the circuit automatically restores itself within 30 seconds, ensuring continuous power supply.
- Tatūnga ratarata-kaiwhakamahi: Clear setting instructions are provided on the product's side for quick adjustments.
4. Whakatakotoranga Hangarau

| Tawhā | Uara |
|---|---|
| Supply Terminals | N, L |
| Whakatauria Voltage | AC 110V; DC 85-300V |
| Auautanga Whakatau | 40/50/60 / 70Hz |
| >U Setting Range (Overvoltage) | AC130-300V; DC130-300V |
| <U Setting Range (Undervoltage) | AC80-210V; DC85-210V |
| Voltage Hīterei | 5V |
| Whakawhanatage Roa Haerenga | 0.5s |
| Voltage Tika | <1% |
| Max. Operating Phase Voltage | 350V |
| Max. Te Mahi o Naianei | 40A/63A |
| Te teitei | ≤2000m |
| Mahi | Tiaki Uira |
| Te Haumaama Paanga Whakaaetia | ≤50% at 40°C (Without Condensation) |
| Te Paemahana Ambient | -25°C ~ +55°C |
| Taumaha Kupenga | 159g |
| Rahi | 81*36*66mm |
5. Tāuta me te Waea
Proper installation is crucial for the safe and effective operation of the MARSTEK Smart Circuit Breaker. Refer to the wiring diagram below and follow all safety precautions.

Hipanga Tāuta:
- Momotu Hiko: Before starting any electrical work, ensure all power to the circuit is completely disconnected at the main service panel. Verify with a voltage Kaiwhakamatautau.
- Whakapiki: Mount the circuit breaker securely in a suitable electrical enclosure or panel. The device is designed for DIN rail mounting or screw mounting.
- Waea Whakauru: Connect the incoming Neutral (N) wire to the terminal marked 'N IN' and the incoming Live (L) wire to the terminal marked 'L IN'.
- Waea Putanga: Connect the outgoing Neutral (N) wire from the terminal marked 'N OUT' and the outgoing Live (L) wire from the terminal marked 'L OUT' to the load you wish to protect.
- Hononga Haumaru: Ensure all terminal screws are tightened securely to prevent loose connections, which can cause overheating or intermittent operation.
- Whakaora Hiko: Once all connections are verified and secure, restore power to the circuit at the main service panel.
6. Operation and Parameter Settings
Upon power-up, the device will display real-time voltage and current. You can adjust the protection parameters to suit your specific needs.
Adjusting Protection Parameters:
- Whakauruhia nga Tautuhinga: Pehia roa te SET button until the display changes, indicating entry into the settings menu.
- Navigate Parameters: Whakamahia te Up (▲) me Ki raro (▼) buttons to cycle through the available parameters (e.g., overvoltage trip value, undervoltage trip value, overcurrent trip value, recovery delay time).
- Tīpakohia te Tawhā: Pehia te SET button briefly to select the currently displayed parameter for adjustment.
- Whakatika Uara: Whakamahia te Up (▲) me Ki raro (▼) buttons to change the parameter's value.
- Whakaū me te Puta: Perehi SET again to confirm the new value and move to the next parameter. To exit the settings menu at any time, long press the SET pātene.
Default Protection Settings:
- Whakawhanatage Haerenga: 140V
- Whakaurutage Haerenga: 90V
- Overcurrent Trip: 63A
- Automatic Recovery Delay: 30 seconds
Automatic Reset Function:
In the event of an overvoltage, whakahekeheketage, or overcurrent condition, the circuit breaker will automatically cut off power to protect the connected load. After a default delay of 30 seconds, the device will attempt to restore power. If the fault condition persists, it will remain disconnected and attempt to reset again after another delay.

- Upon detection of overvoltage, whakahekeheketage, or overcurrent, the circuit is cut off.
- A default delay of 30 seconds begins.
- After 30 seconds, the circuit attempts to reset automatically. If the abnormality is resolved, power is restored. If the abnormality persists, the device continues to wait before another reset attempt.
7. Tiaki
The MARSTEK Smart Circuit Breaker HF-00095 requires minimal maintenance to ensure optimal performance and longevity.
- Tirotiro auau: Periodically inspect the device for any visible damage, discoloration, or loose wiring connections. Address any issues promptly.
- Te horoi: Ensure the ventilation openings are clear of dust and debris to prevent overheating. Clean the display and exterior with a soft, dry cloth. Do not use abrasive cleaners, solvents, or liquids directly on the device.
- Nga Tikanga Taiao: Ensure the device operates within the specified ambient temperature and humidity ranges to prevent malfunction.
8. Te Raru
If you encounter issues with your MARSTEK Smart Circuit Breaker, refer to the following troubleshooting guide:
- Kaore te taputapu i te hiko:
- Check if the main circuit breaker supplying power to the device is in the ON position.
- Verify that the input (IN) wiring connections are secure and correctly wired.
- Me whakarite te tuku voltage is within the rated range (AC 110V; DC 85-300V).
- Circuit trips frequently:
- Review your set overvoltage, whakahekeheketage, and overcurrent parameters. Ensure they are appropriate for your connected load and typical operating conditions.
- Check for actual electrical faults (e.g., short circuits, overloads) in the connected circuit or appliance.
- Ensure the load current does not exceed the maximum operating current (63A).
- Display not showing correct values or is blank:
- Manatokohia he haumaru, he tika hoki nga hononga waea.
- If the issue persists after checking connections and power, the device may require service.
- Device does not reset automatically:
- Ensure the fault condition (overvoltage, whakahekeheketage, overcurrent) has been resolved. The device will not reset if the fault persists.
- Check the automatic recovery delay setting.
9. Pūtāhui me te Tautoko
For detailed warranty information regarding your MARSTEK Smart Circuit Breaker HF-00095, please refer to the product packaging or visit the official MARSTEK webpae.
For technical support, troubleshooting assistance, or any other inquiries, please contact MARSTEK customer service through their official contact channels, which can typically be found on their webpae, tuhinga hua ranei.