sinocare GoldAQ100

SINOCARE GOLD AQ PLUS Blood Glucose Monitor User Manual

Model: GoldAQ100

1. Kupu Whakataki

The SINOCARE GOLD AQ PLUS Blood Glucose Monitor is a state-of-the-art system designed for fast, accurate, and reliable blood glucose measurements. This device utilizes unique gold electrode test strips for enhanced precision and offers a convenient, no-coding operation. With its rapid 5-second result time and extensive 999-test memory, it provides an efficient way to monitor blood sugar levels.

Sinocare Gold AQ Plus Blood Glucose Monitoring System kit including meter, test strips, lancets, lancing device, and case.

Whakaahuatanga: This image displays the complete Sinocare Gold AQ Plus Blood Glucose Monitoring System kit. It includes the main glucose meter, boxes of test strips, a lancing device, lancets, and a carrying case, providing a comprehensive view o nga waahanga katoa.

2. Ihirangi mokete

Manatokona kei roto katoa nga mea kei roto i te kete:

  • Sinocare Gold AQ Plus Glucometer Device
  • Gold AQ Plus Test Strips (quantity as per kit)
  • Lancets (quantity as per kit)
  • Pūrere Taurewa
  • Te Kawe i te Keehi
  • Pukapuka Kaiwhakamahi (tenei tuhinga)

3. Tatūnga

3.1. Tāuta Pūhiko

The Sinocare Gold AQ Plus meter requires batteries (not included in all kits). Open the battery compartment on the back of the device and insert the specified battery type, ensuring correct polarity. Close the compartment securely.

3.2. Preparing the Lancing Device

  1. Unscrew the cap of the lancing device.
  2. Whakauruhia he toho hou ki roto i te pupuri taohi.
  3. Wetekina te taupoki tiaki mai i te raneti.
  4. Whakakapia te taupoki o te taputapu wero.
  5. Adjust the penetration depth by rotating the cap. Start with a shallower setting and adjust as needed for sufficient blood sample.
  6. Pull back the cocking barrel until it clicks, indicating it is ready for use.

3.3. Inserting a Test Strip

The Sinocare Gold AQ Plus meter requires no coding. Simply insert a Gold AQ Plus test strip into the test strip port of the meter. The meter will automatically turn on and display a symbol indicating it is ready for a blood sample.

Sinocare Gold AQ Plus meter with icons indicating no coding, 0.8uL blood volume, 59g weight, and LCD display.

Whakaahuatanga: This image illustrates key features of the Sinocare Gold AQ Plus meter, including its no-coding requirement, minimal blood sample volume (0.8uL), lightweight design (59g), and clear LCD display screen.

4. Operating the Device (Blood Glucose Testing)

4.1. Obtaining a Blood Sample

  1. Horoia pai ō ringaringa ki te hopi me te wai māhana, kātahi ka whakamaroke rawatia.
  2. Choose a fingertip for the blood sample.
  3. Place the lancing device firmly against the chosen fingertip and press the release button.
  4. Gently squeeze the finger until a small drop of blood forms. The lancing device is designed for painless collection, supporting 180-degree blood collection for ease of use.

4.2. Applying Blood to the Test Strip

  1. Touch the absorbent tip of the test strip to the blood drop. The strip will draw the blood into the reaction area. Do not apply blood to the top of the strip.
  2. Ensure the blood sample completely fills the confirmation window on the test strip.

4.3. Reading the Result

I muri i te toto sample is applied, the meter will begin a countdown. The blood glucose result will appear on the display in just 5 seconds. The meter also features a voice reminder function for convenience.

Sinocare Gold AQ Plus meter displaying a rapid result in 5 seconds.

Whakaahuatanga: The image highlights the rapid testing capability of the Sinocare Gold AQ Plus meter, showing the device with a digital display indicating a blood glucose reading obtained in just 5 seconds.

4.4. Mahi Mahara

The Sinocare Gold AQ Plus meter automatically stores up to 999 blood glucose test results. You can review past results by pressing the memory button on the device. This feature helps you track your blood sugar levels and identify trends over time.

Sinocare Gold AQ Plus meter showing 999 test results memory capacity.

Whakaahuatanga: The image emphasizes the extensive memory capacity of the Sinocare Gold AQ Plus meter, capable of storing up to 999 blood glucose test results, aiding in long-term monitoring.

Diagram of Lunula Nano technology in Sinocare test strip supporting 180-degree blood collection.

Whakaahuatanga: This diagram explains the Lunula Nano technology used in the test strips, demonstrating its ability to support 180-degree blood collection for easier and more flexible sampling, along with features like wide HCT range, strong anti-interference, and accurate results.

5. Tiaki

5.1. Te Horoi i te Mita

Wipe the meter exterior with a soft, damp cloth. Do not immerse the meter in water or use harsh cleaning agents. Ensure no liquid enters the test strip port.

5.2. Rokiroki

  • Store the meter and test strips in their original carrying case in a cool, dry place.
  • Keep away from direct sunlight, heat, and moisture.
  • Do not store test strips in a refrigerator.
  • Ensure test strip vials are tightly closed immediately after removing a strip to prevent exposure to air and moisture.
  • Dispose of used lancets and test strips properly in a sharps container or according to local regulations.

6. Te Raru

If you encounter issues with your Sinocare Gold AQ Plus Blood Glucose Monitor, refer to the following common problems and solutions:

  • Meter does not turn on: Check if batteries are correctly installed. Replace batteries if necessary.
  • Karere hapa kei te whakaatu: Tirohia te waehere hapa motuhake i roto i te pukapuka kaiwhakamahi katoa mō ngā tohutohu taipitopito. Ko ngā take noa ko te korenga o te toto.ampte rīpene whakamātautau kua pau te wā, te rīpene whakamātautau kua pakaru rānei.
  • Inaccurate results: Ensure test strips are not expired and stored correctly. Verify proper blood sample application. Consult a healthcare professional if results consistently seem incorrect.
  • Karekau he toto sample drawn: Adjust the lancing device's penetration depth. Ensure the lancing device is cocked before use.

Mo nga take e mau tonu ana, me waea atu ki te tautoko a nga kaihoko.

7. Whakatakotoranga

Waitohusinocare
Tau tauiraGoldAQ100
Taumaha Tūemi200 g
Rahi Hua (LxWxH)18.5 x 6 x 16.5 cm
Te Maharahara999 Nga Hua Whakamatau
Toto Sampte Volume0.8 µL
Te Wa Whakamatau5 hēkona
Coding RequiredKao
Nga Waahanga kei rotoGlucometer Device, Strips, Lancets and Lancet Device

8. Pūtāhui me te Tautoko

8.1. Nga Korero Whakaputanga

For specific warranty terms and conditions, please refer to the warranty card included with your product or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.

8.2. Tautoko Kiritaki

If you have any questions, require technical assistance, or need to report an issue with your Sinocare Gold AQ Plus Blood Glucose Monitor, please contact:

  • Kaihanga: Changsha Sinocare Inc.
  • Kai kawemai (Inia): Pts Diagnostics India Pvt. Ltd

Please visit the official Sinocare website or contact your local distributor for the most up-to-date contact information and support resources.

Tuhinga e pa ana - GoldAQ100

Preview Sinocare Safe AQ pro I Blood Glucose Test Strip Package Insert
Official package insert for Sinocare Safe AQ pro I Blood Glucose Test Strips, providing detailed information on intended use, testing procedures, results interpretation, storage, and performance characteristics for diabetes management.
Preview Sinocare Safe AQ Voice Quick Guide: Easy Blood Glucose Monitoring
A concise guide to using the Sinocare Safe AQ Voice blood glucose meter for quick and accurate blood sugar testing. Learn how to prepare materials, perform the test, and interpret results.
Preview Sinocare Safe AQ Smart Blood Glucose Meter - Operation Manual
Concise operation manual for the Sinocare Safe AQ Smart blood glucose meter, detailing preparation, usage steps, and important notes for accurate blood sugar testing.
Preview Safe AQ Smart, Safe AQ Voice, Safe AQ Air Blood Glucose Meter User Manual
Comprehensive user manual for the Sinocare Safe AQ Smart, Safe AQ Voice, and Safe AQ Air blood glucose monitoring systems. Learn about intended use, safety information, test principles, operation, troubleshooting, and maintenance.
Preview Sinocare Safe AQ Pro Series Toto Glucose Monitoring System Manual
Ko tenei pukapuka kaiwhakamahi e whakarato ana i nga tohutohu matawhānui mo te Sinocare Safe AQ Pro Series Blood Glucose Monitoring System, e hipoki ana i te tatūnga, te mahi, te tiaki, te rapu raruraru, me nga korero haumaru nui mo te aroturuki tika i te taumata huka toto.
Preview Sinocare Safe AQ Pro Series Toto Glucose Monitoring System Manual
Comprehensive user manual for the Sinocare Safe AQ Pro Series blood glucose monitoring system, covering setup, operation, safety guidelines, troubleshooting, and specifications for accurate diabetes management.