GENMAX GM-PUMP

Pukapuka Tohutohu mō te GMEFP mō te Papu Wahie Hiko GENMAX 12V DC

Model: GM-PUMP

1. Kupu Whakataki

The GENMAX GMEFP is a 12V DC electric fuel pump designed to automatically transfer gasoline from an external fuel tank to your GENMAX small inverter generator. This system ensures continuous operation of your generator without manual refueling, enhancing convenience and efficiency.

This manual provides essential information for the safe and effective installation, operation, and maintenance of your GENMAX GMEFP fuel pump. Please read it thoroughly before use and retain it for future reference.

GENMAX GMEFP Electric Fuel Pump
Image 1.1: The GENMAX GMEFP 12V DC Electric Fuel Pump, designed for automatic fuel transfer.

2. Nga korero haumaru

WARNING: Gasoline is highly flammable and its vapors are explosive. Always handle fuel with extreme caution.

3. Nga Hua o te Hua

4. Ihirangi mokete

Manatokohia ko nga mea katoa kei raro nei kei roto i to kete:

GENMAX GMEFP Fuel Pump and Accessories
Image 4.1: The GENMAX GMEFP fuel pump shown with its included accessories: 12V DC power plugs (crocodile clips and cigarette lighter type) and a fuel hose with a primer bulb. These components facilitate connection to various power sources and external fuel tanks.

5. Tatūnga me te Tāuta

Proper installation is crucial for the safe and efficient operation of the fuel pump. Follow these steps carefully:

5.1 Tirohanga i mua i te whakaurunga

GENMAX GMEFP Fuel Pump Dimensions and Thread Size
Image 5.1: Detailed dimensions of the GENMAX GMEFP fuel pump, including thread size (1.95 inches diameter, 0.18 inches pitch) and overall height (7.3 inches), crucial for compatibility with external fuel tanks.

5.2 Connecting the Fuel Pump

  1. Install the Fuel Pump: Securely screw the GENMAX GMEFP fuel pump into the fuel tank opening of your generator. Ensure a tight seal to prevent leaks.
  2. Connect Fuel Hose to External Tank: Connect one end of the provided fuel hose (with the primer bulb) to the outflow port of your external fuel tank. Ensure this connection is secure.
  3. Connect Fuel Hose to Pump: Connect the other end of the fuel hose to the tubing connection port on the GENMAX GMEFP fuel pump. This port indicates fuel flow to the generator.
  4. Hono Hono: Choose the appropriate 12V DC power plug (crocodile clips or cigarette lighter) and connect it to the 12V DC power cable of the fuel pump. Then, connect the power plug to your generator's 12V DC output or another suitable 12V DC power source.
  5. Turanga: Place the external fuel tank on a stable surface, ensuring it is below the generator's fuel tank for optimal gravity feed assistance during priming. Ensure the fuel hose is not kinked and is clear of hot engine components, especially the muffler.
GENMAX GMEFP Fuel Pump Connection Diagram
Image 5.2: Diagram illustrating the connection of the GENMAX GMEFP fuel pump to a generator and an external fuel tank. It shows the 12V DC power cable connection and the fuel hose routing, emphasizing to keep the hose away from the muffler.
GENMAX GMEFP Fuel Pump in operation with generator
Image 5.3: The GENMAX GMEFP fuel pump installed on a GENMAX generator, connected to an external red fuel tank. This setup demonstrates the automatic fuel replenishment system in use.

6. Nga Tohutohu Whakahaere

Once the fuel pump is correctly installed and connected, follow these steps for operation:

  1. Prime te Pūnaha wahie: Before starting the generator, use the primer bulb on the fuel hose to manually draw gasoline from the external tank towards the pump. Squeeze the bulb until it feels firm, indicating fuel has reached the pump.
  2. Tīmatahia te Kaihanga: Start your GENMAX inverter generator according to its own instruction manual.
  3. Activate the Fuel Pump: Locate the switch on the GENMAX GMEFP fuel pump and turn it to the "ON" position. The pump will begin to monitor the fuel level in the generator's tank.
  4. Automatic Refueling: When the generator's fuel level drops to a predetermined low point, the GMEFP pump will automatically activate and transfer fuel from the external tank to the generator's tank.
  5. Overfill Protection: The pump's internal fault detection system will automatically stop the fuel transfer once the generator's tank is full, preventing overfilling and ensuring safe operation.
  6. Mahi Tonu: The pump will cycle on and off as needed to maintain the fuel level, allowing for extended, unattended generator operation.

Tuhipoka: If the generator is not a GENMAX model, ensure its fuel tank depth and fuel cap thread are compatible with the pump before use.

7. Tiaki

Regular maintenance ensures the longevity and reliable performance of your GENMAX GMEFP fuel pump.

8. Te Raru

If you encounter issues with your GENMAX GMEFP fuel pump, refer to the following common troubleshooting steps:

If these steps do not resolve the issue, please contact GENMAX customer support for assistance.

9. Whakatakotoranga

WhakatakotorangaTaipitopito
TauiraGM-PUMP
WaitohuGENMAX
Puna Mana12V DC
Aratau MahiAunoa
Momo haupenehīni
Rauemi tinanaKirihou
Taumaha Tūemi3.65 pauna (1.66 Kirokaramu)
Momo WhakaekeMaunga Tane
Applicable Generator Power2kW to 5kW (GENMAX inverter generators)
Compatible External Tank Capacity5-17 Gallons (tank not included)
Required Tank Port Depth> 3.74 inihi
Required Tank Port Diameter2.17 inihi
Required Tank Port Thread Pitch~ 0.18 inches

10. Pūtāhui me te Tautoko

The GENMAX GMEFP fuel pump comes with a 1-tau pūtāhui mai i te ra o te hokonga.

GENMAX also provides Tautoko hangarau kore utu mō te wa katoa from experienced experts. If you have any questions, require assistance with installation, operation, or troubleshooting, please do not hesitate to contact GENMAX customer support.

For warranty claims or technical support, please refer to the contact information provided on the GENMAX official webpaetukutuku, ngā rauemi rēhitatanga hua rānei.

Tuhinga e pa ana - GM-PUMP

Preview Pukapuka Kaiwhakamahi mō te Pūkaha Hurihuri Wahie-Tokotoru Genmax GM17000iETC
He pukapuka ā-ringa whānui mō te Genmax GM17000iETC Tri-Fuel Inverter Generator, e kapi ana i te whakahaere, te haumaru, te tiaki, te rapurongoā, me ngā whakaritenga hangarau. Akohia me pēhea te whakahaere me te tiaki haumaru i tō generator mō te penehīni, te LPG, me ngā wahie hau māori.
Preview Pukapuka Kaiwhakamahi mō te Pūkaha Hurihuri Wahie-Toru GENMAX GM17000iETC
He pukapuka kaiwhakamahi whānui mō te GENMAX GM17000iETC Tri-Fuel Inverter Generator, e kapi ana i te haumaru, te whakahaere, te tiaki, te rapurongoā, me ngā whakaritenga hangarau. Akohia me pēhea te whakahaere me te tiaki haumaru i tō generator mō te penehīni, te LPG, me te hau māori.
Preview Pukapuka Kaiwhakamahi mō te Pūhiko Kawe GENMAX GM12000E/GM12000ED
He pukapuka kaiwhakamahi whānui mō ngā miihini whakaputa penehīni kawe GENMAX GM12000E me GM12000ED, e kapi ana i te whakahaere, te haumaru, te tiaki, te rapurongoā, me ngā whakatakotoranga hangarau. Kei roto ko te āheinga wahie-rua mō te tauira GM12000ED.
Preview Genmax GM7250iEDC Inverter Generator Manual a te Kaiwhakamahi
Ko te pukapuka a te kaiwhakamahi mo te Genmax GM7250iEDC te kawe i te kaihuri hinu e rua. Ka hipoki i nga whakatupatotanga mo te haumaru, nga tohutohu whakahaere, nga raarangi tiaki, te rapu raru, me nga whakaritenga hangarau mo te whakamahi penehi me te LPG.
Preview Genmax GM15000ET Tri-Fuel Portable Generator Manual a te Kaiwhakamahi
He pukapuka kaiwhakamahi whānui mō te Genmax GM15000ET Tri-Fuel Portable Generator, e kapi ana i te haumaru, te whakahaere, te huihuinga, te tiaki, me ngā whakaritenga hangarau mō te penehīni, te LPG, me te hau māori.
Preview GENMAX GM7500iAED Inverter Generator Manual Kaiwhakamahi: Haumarutanga, Mahi, me te Tiaki
He pukapuka ā-ringa whaimana mō te Pūkaha Whakahuri Wahie Takirua Kawe GENMAX GM7500iAED. Kei roto ko te whakatūnga, te whakahaere, ngā whakatūpato haumaru, te maramataka tiaki, te rapurongoā, ngā whakaritenga hangarau, me te whiriwhiri i te pūkaha tika. Kei roto ko ngā taipitopito mō te whakamahinga penehīni me te LPG.