ZEBRONICS U735

ZEBRONICS U735 600VA/360W UPS User Manual

Tauira: U735

1. Kupu Whakataki

This manual provides essential information for the proper installation, operation, and maintenance of your ZEBRONICS U735 600VA/360W Uninterruptible Power Supply (UPS). Please read this manual thoroughly before using the product to ensure safe and efficient operation.

The ZEBRONICS U735 is a microcontroller-based line-interactive UPS designed to provide reliable power backup and protection for office computers and home PCs. It features automatic voltage regulation (AVR), auto-restart functionality, and built-in protection mechanisms.

2. Nga Tohutohu Haumaru

  • Kaua e whakatuwheratia te UPS casing. Kaore he waahanga e taea ana e te kaiwhakamahi ki roto. Tukuna nga ratonga katoa ki nga kaimahi ratonga whai tohu.
  • Do not connect appliances that draw high current, such as laser printers, vacuum cleaners, or heaters, to the UPS.
  • Me whakarite kia whakanohoia te UPS ki tētahi wāhi e pai ana te hau, kia matara atu i te rā tika, i ngā pūtake wera, me te makuku.
  • Connect the UPS to a properly grounded power outlet.
  • Do not use the UPS for medical equipment or life-support systems.
  • This UPS is not designed for routers or other micro-load devices that draw very low power, as it may lead to premature shutdown.

3. Ihirangi mokete

Manatokona kei roto katoa nga mea kei roto i te kete:

  • ZEBRONICS U735 UPS Unit
  • Pukapuka Kaiwhakamahi (tenei tuhinga)
  • Waea Hiko

4. Hua Neke Atuview

ZEBRONICS U735 UPS Front View

Whakaahua 1: Mua view of the ZEBRONICS U735 UPS, showing the power button and LED indicators.

The ZEBRONICS U735 UPS is equipped with the following key features:

  • Line Interactive UPS: Provides power conditioning and battery backup.
  • Microcontroller Based Design: Ensures efficient and reliable operation.
  • Aunoa Voltage Ture (AVR): Stabilizes incoming AC power to protect connected devices from voltage huringa.
  • Auto Restart while AC is Recovering: Automatically restarts connected equipment when mains power returns after an outage.
  • Generator Compatible: Can operate with generator power sources.
  • Whakanuia me te Buck AVR: Corrects both undervoltage me te overvoltage conditions without using battery power.
  • Parenga-roto: Includes overload protection.
  • No Load Auto Shutdown: Automatically shuts down in battery mode if no load is detected, conserving battery life.
  • Taumahi Tīmata Matao: Allows the UPS to be powered on using battery power without an AC input.
ZEBRONICS U735 UPS Features Overview

Figure 2: Visual representation of key features including Overload Protection, Microcontroller Based, Sleep Mode Charging, Cold Start, Generator Compatible, Boost & Buck AVR, LED & Audible Alarms, Auto Restart, and Simulated Sine Wave.

5. Tatūnga me te Tāuta

5.1 Whakanoho

Place the UPS on a flat, stable surface in a clean, dry, and well-ventilated indoor environment. Avoid areas with excessive dust, humidity, or extreme temperatures. Ensure there is adequate clearance around the UPS for proper airflow.

5.2 Hononga Pūrere

ZEBRONICS U735 UPS Rear Panel with Sockets

Whakaahua 3: Whakamuri view of the ZEBRONICS U735 UPS, showing the three output sockets for connecting devices.

  1. Connect the UPS power cable to a grounded wall outlet.
  2. Connect your computer, monitor, and other essential peripherals (up to 3 devices) to the output sockets on the rear panel of the UPS.
  3. Me whakarite kia mau nga hononga katoa.

Tuhipoka: The UPS is designed for typical computer setups. Avoid connecting devices with high power consumption or those that require a pure sine wave output, as this UPS provides a simulated sine wave.

6. Nga Tohutohu Whakahaere

6.1 Kei te Hiko / Weto

  • Hei Whakahiko: Press and hold the power button on the front panel until the LED indicators illuminate.
  • Hei Whakaweto: Press and hold the power button until the LED indicators turn off.

6.2 LED Indicators and Audible Alarms

Kei te papa o mua ngā tohu LED hei whakaatu i te tūnga o te UPS:

  • LED Kakariki: Indicates normal AC mode operation.
  • LED kōwhai: Indicates battery mode operation (during a power outagme).
  • LED Whero: E tohu ana i tētahi hapa, i tētahi taumaha rawa rānei.

Audible alarms will sound to indicate specific conditions, such as battery mode, low battery, or overload. Refer to the troubleshooting section for alarm interpretations.

6.3 Mahi Tīmatanga Matao

The UPS supports a cold start function, allowing you to power on the UPS and connected devices using battery power even when there is no AC input. To perform a cold start, ensure the UPS is off, then press and hold the power button for a few seconds until the UPS powers on.

ZEBRONICS U735 UPS with Cold Start feature

Figure 4: The UPS unit highlighting the Cold Start capability.

7. Tiaki

7.1 Tiaki Pūhiko

  • For optimal battery life, ensure the UPS is connected to AC power and charging for at least 8 hours before initial use.
  • Avoid frequent deep discharges of the battery.
  • If the UPS is stored for an extended period, recharge it every three months to prevent battery degradation.

7.2 Te horoi

Clean the exterior of the UPS with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust and obstructions.

8. Te Raru

This section provides solutions to common issues you might encounter with your UPS. If the problem persists, contact customer support.

RaruraruTake peaRongoā
Kaore te UPS e huri.Battery discharged; Power cable not connected; UPS fault.Connect to AC power and allow to charge; Check power cable connection; Contact support.
UPS beeps continuously in battery mode.Whakatupato pākahiko iti.Save your work and shut down connected equipment immediately.
Ka huri te UPS ki te aratau pākahiko.Unstable AC input voltage; Overload.Check AC power quality; Reduce connected load.
Kei te ka te LED Whero.Overload; Internal fault.Disconnect some devices; Contact support.
Short battery backup time.Battery not fully charged; Battery aging; Overload.Ensure full charge; Consider battery replacement (by qualified personnel); Reduce load.

9. Whakatakotoranga

ĀhuahiraTaipitopito
WaitohuWAIATA
Tau tauiraU735
Te kaha600VA / 360W
MomoRaina Interactive UPS
Whakauru Voltage240 Volts (Wide Input Range)
Wā Utu Pūhiko8 Hāora (ki te 90% te kaha)
Toharite Pūhiko OraApproximately 1.45 Hours (depending on load)
Rahi Hua (LxWxH)14.2 x 32.6 x 21.3 cm
Taumaha Tūemi3.82 kg
Tauwehe PukaWhatanga
Whenua TaketakeHaina

Tuhipoka: Ko nga korero ka huri ki te kore korero i mua.

10. Hua Ataata Nekeview

Ataata 1: Kua mutuview of the ZEBRONICS U735 UPS features, including auto-restart, automatic voltage regulation, wide input range, microcontroller-based operation, and no-load auto shutdown.

11. Pūtāhui me te Tautoko

For warranty information, service, or technical support, please refer to the warranty card included with your product or visit the official ZEBRONICS webpae. Puritia to riirii hoko hei tohu mo te hoko mo nga kereme whakamana.

Kaihanga: ZEBRONICS INDIA PRIVATE LIMITED

Tuhinga e pa ana - U735

Preview Zebronics ZEB-U735 Uninterruptible Power Supply User Manual
User manual for the Zebronics ZEB-U735 Uninterruptible Power Supply (UPS), detailing safety instructions, installation, operation, features, specifications, and troubleshooting for reliable power backup.
Preview Zebronics ZEB-MLS750 UPS User Manual - Installation, Features, and Specifications
Comprehensive user manual for the Zebronics ZEB-MLS750 Uninterruptible Power Supply (UPS). Learn about safety instructions, installation, product features, specifications, and troubleshooting for reliable backup power.
Preview Zebronics ZEB-U725 UPS User Manual: Safety, Installation, Features, and Specifications
Comprehensive user manual for the Zebronics ZEB-U725 Uninterruptible Power Supply (UPS). Provides detailed information on important safety instructions, installation procedures, product features, technical specifications, and troubleshooting.
Preview Zebronics ZEB-Delight Pro Mini Soundbar Pukapuka Kaiwhakamahi - Nga waahanga, Whakatakotoranga, me te Aratohu Mahi
Ko tenei pukapuka kaiwhakamahi he korero matawhānui mo te Zebronics ZEB-Delight Pro Mini Soundbar. Kei roto i nga ahuatanga o te hua, nga whakaritenga hangarau, nga ihirangi kete, nga whakaahuatanga paatene, me nga tohutohu taahiraa-i-te-taahiraa mo nga momo momo tae atu ki te Nihokikorangi, USB, mSD, AUX, me te Irirangi FM. Akohia me pehea te utu i te taputapu, te whakamahi i nga mahi waea, me te whakarite i te aratau TWS.
Preview Zebronics ZEB-MLS755 UPS User Manual: Features, Specifications, and Troubleshooting
Comprehensive user manual for the Zebronics ZEB-MLS755 Uninterruptible Power Supply (UPS). Learn about safety instructions, installation, product features, specifications, LED indicators, alarms, and troubleshooting tips.
Preview Zebronics ZEB-VITA Tukuoro Nihokikorangi Mahinga Kaiwhakamahi
He pukapuka whakamahi matawhānui mo te Zebronics ZEB-VITA Portable BT Speaker. Akohia nga ahuatanga, nga korero, nga mahi paatene, te utu, te takirua Nihokikorangi, Micro SD/USB, AUX, reo irirangi FM, me nga momo TWS.