ERICKHILL ROOK800P

ERICKHILL Infrared Thermometer Gun ROOK800P User Manual

Model: ROOK800P | Brand: ERICKHILL

1. Kupu Whakataki

The ERICKHILL Infrared Thermometer Gun ROOK800P is a versatile dual-mode temperature measurement device, combining a non-contact infrared sensor with a detachable stainless-steel probe. It is designed for accurate and rapid temperature readings across a wide range of applications, from cooking and BBQ to industrial and home use. This manual provides essential information for safe and effective operation.

2. Nga korero haumaru

WHAKATŪPATO: This device uses a Class II laser. Do not aim the laser directly at eyes or reflective surfaces. Avoid direct exposure to the laser beam. This product is not a medical device and should not be used for measuring human body temperature.

3. Hua Neke Atuview

The ERICKHILL ROOK800P features a robust design with an easy-to-read backlit LCD display. It includes both non-contact infrared measurement and a contact probe for internal temperatures.

ERICKHILL Infrared Thermometer Gun ROOK800P with probe and carrying case

Figure 1: ERICKHILL Infrared Thermometer Gun ROOK800P with its detachable probe and protective carrying case.

4. Tatūnga

4.1 Tāuta Pūhiko

  1. Kimihia te wahanga pākahiko i runga i te kakau.
  2. Whakatuwheratia te uhi o te wahanga.
  3. Kōkuhu 2 pākahiko AAA, kia tika te polarity (+/-).
  4. Katia kia mau te uhi o te wahanga pākahiko.

4.2 Attaching the Temperature Probe

The detachable meat probe connects to a port on the side of the thermometer gun. Simply insert the probe's jack into the designated port until it clicks into place.

Video: Official ERICKHILL STORE video demonstrating the product features, including probe attachment and usage.

5. Nga Tohutohu Whakahaere

5.1 Hiko / Whakaweto

To power on the device, pull the trigger. The device will automatically power off after 15 seconds of inactivity to conserve battery life.

5.2 Switching Measurement Modes (IR / Probe)

Pehia te IR/PR button to toggle between Infrared (non-contact) and Probe (contact) measurement modes. The display will indicate the active mode.

5.3 Temperature Units (°C / °F)

Pehia te ° C / ° F. pātene hei huri i waenga i nga wae pāmahana Celsius me Fahrenheit.

5.4 Laser Aiming

In IR mode, the laser pointer can be activated or deactivated by pressing the laser button. The laser helps pinpoint the measurement area for non-contact readings.

5.5 Te Whakatikatika i te Tukunga

The emissivity setting (0.10-0.99) allows for precise temperature measurements across various materials. Refer to the manual's emissivity chart for common materials. Press the MODE button to access emissivity settings.

Infrared thermometer displaying adjustable emissivity setting from 0.10 to 0.99

Figure 2: The thermometer's display showing the adjustable emissivity setting, crucial for accurate readings on different surfaces.

5.6 Max/Min/Avg Modes

Pehia te MODE button repeatedly to cycle through Max, Min, and Average temperature display modes during continuous measurement.

5.7 Using IR Mode (Non-Contact)

Point the infrared sensor at the target object and pull the trigger. The laser will indicate the measurement spot. The display will show the surface temperature. Maintain an optimal distance for accuracy (refer to the device's spot ratio diagram, typically around 360mm for a 30mm spot).

Person using the infrared thermometer to measure the surface temperature of a cooking steak on a griddle.

Figure 3: Measuring the surface temperature of food on a griddle using the non-contact infrared function.

5.8 Using Probe Mode (Contact)

Ensure the probe is securely attached and the device is in Probe mode. Insert the stainless-steel probe into the object (e.g., meat, liquid) to measure its internal temperature. Allow a few seconds for the reading to stabilize.

Person using the detachable probe of the ERICKHILL thermometer to measure the internal temperature of a steak.

Figure 4: Using the detachable probe to accurately measure the internal temperature of food.

6. Nga tono

The ERICKHILL ROOK800P is suitable for a wide array of temperature measurement tasks:

Collage showing various applications of the ERICKHILL thermometer, including cooking, automotive checks, and general temperature measurement.

Figure 5: Versatile applications of the thermometer, from kitchen to automotive and industrial settings.

7. Whakatakotoranga

ĀhuahiraUara
Te Awhe Pawera IR-50°C ki te 800°C (-58°F ki te 1472°F)
Te Awhe Paemahana Probe-50°C ki te 300°C (-58°F ki te 572°F)
Tika±2°C
Wā Whakautu0.5 hēkona
Tawhiti-ki-Spot Ratio12:1
HarikiriAdjustable (0.10-0.99)
Puna Mana2 x AAA Battery (kei roto)
Hiko-Aunoa15 hēkona (approx.)
Momo WhakaatuMamati, LCD Whakamuri
RauemiABS Body, Stainless-Steel Probe

8. Tiaki

9. Te Raru

RaruraruTe Take Taea / Rongoa
No display / Device won't turn onCheck battery installation and replace if necessary. Ensure the trigger is fully pressed.
Inaccurate IR readingsVerify emissivity setting for the target material. Ensure proper distance-to-spot ratio. Avoid measuring through glass or highly reflective surfaces. Allow device to acclimate to ambient temperature if moved from extreme conditions.
Inaccurate Probe readingsEnsure the probe is fully inserted into the object and has sufficient time to stabilize. Check for proper connection of the probe to the device.
Taiaho kore e kiteaEnsure the laser aiming function is activated (check display icon).

10. Pūtāhui me te Tautoko

ERICKHILL products typically come with a manufacturer's warranty. Please refer to the product packaging or the official ERICKHILL webpae mo nga taipitopito whakamana motuhake.

For technical support or customer service, please contact ERICKHILL support at: support@erick-hill.com

Tuhinga e pa ana - ROOK800P

Preview ERICKHILL ROOK 400/600 SP IR Thermometer Manual Kaiwhakamahi
He pukapuka whakamahi mo te ERICKHILL ROOK 400 SP me te ROOK 600 SP nga inemahota infrared. Ka whakarato i nga tohutohu mo te mahi, nga ahuatanga, te haumaru, me nga whakaritenga hangarau.
Preview ERICKHILL ER02 EMF Meter Manual Kaiwhakamahi
Tirohia nga kaha o te ERICKHILL ER02 EMF Meter me tenei pukapuka kaiwhakamahi matawhānui. Akohia mo tana mahinga 3-i-1 mo te ine i nga mara hiko, autō, me te reo irirangi, tae atu ki te mahi, nga whakaritenga, me nga aratohu haumaru.
Preview Erickhill RT-100S EMF Meter Manual Kaiwhakamahi
Te pukapuka a te kaiwhakamahi mo te Erickhill RT-100S EMF Meter, e whakaatu ana i ona ahuatanga, mahi, tohu hangarau, me nga tono mo te ine i nga mara hiko, hiko, me te RF.