ACiQ B0DHFF2DKL

Pukapuka Kaiwhakamahi mō te Pūnaha Papu Wera Inverter Waenga ACiQ 2.5 Tana 17 SEER2

Model: B0DHFF2DKL

1. Kupu Whakataki

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. Nga korero haumaru

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • Haumaru Hiko: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • Te Whakahaere Whakataonga: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • Tāutatanga: Installation must be performed by a licensed HVAC professional.
  • Taputapu Tiaki Whaiaro: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. Nga waahanga matua

  • Hangarau Inverter: Provides precise temperature control, reduced energy consumption, and quieter operation.
  • Tino Tino: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • Awhe Mahi Whanui: Reliable performance from -13°F to 122°F.
  • Mahi Ataahua: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • Wae Roa: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • Refrigerant Hoa-Raro: Utilizes R-454B refrigerant.
  • Tāuta Hangore: Supports horizontal and vertical air handler installation.
  • Mana Ataata: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. Nga Waahanga Nekeview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Indoor Air Handler Unit
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • WiFi Wereweti
  • Kaiwhiwhi i te Kaiuru
  • Pūurutau Utu CPS
  • Ngaru Tu
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

Whakaahua 1: Ka mutuview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. Tatūnga me te Tāuta

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 Nga Tirohanga i mua i te whakaurunga

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • Ensure adequate space for both indoor and outdoor units, allowing for proper airflow and maintenance access.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

Whakaahua 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Te Whakatakotoranga o ngā Wāhanga o Waho

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

Whakaahua 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. Nga Tohutohu Whakahaere

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 Tikanga Mahi Taketake

  • Aratau whakamatao: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • Aratau Whakawera: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • Aratau Fan: Ka huri i te hau me te kore whakamahana, whakamatao ranei.
  • Aratau Auto: Ka huri aunoa i waenga i te whakamahana me te whakamatao hei pupuri i te pāmahana kua whakaritea.
ACiQ outdoor unit operating in extreme heat

Whakaahua 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

Whakaahua 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Smart Controls

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

Whakaahua 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. Tiaki

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • Whakakapinga Tātari Hau: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • Whakapai Waehe o waho: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • Pūnaha Whakawai: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • Tirotiro Ngaio: Schedule annual inspections and maintenance by a qualified HVAC technician.

8. Te Raru

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • Kore Mana: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • He iti rawa te whakawera/te whakamatao: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • Haruru rerekee: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • Nga Rire Wai: Check condensate drain line for blockages.

9. Whakatakotoranga

Dimensions of ACiQ indoor and outdoor units

Whakaahua 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

Whakaahua 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

Whakaahua 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

ĀhuahiraTaipitopito
Te Whakamaoho31,000 BTU/haora
Te Raukaha Whakawera30,000 BTU/hr (at 47°F)
SEER2 Whakatauranga18.8
HSPF2 Whakatauranga9.7
Momo TereR-454B
Whakawhiwhi Hiko Wae Roto115/208/230V, 60Hz, 1Ph
Whakawhiwhi Hiko Waehe o waho208/230V, 60Hz, 1Ph
Te Roa Paipa Max164 ft (50m)
Max Height Difference82 ft (25m)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
Taumaha Kupenga o Roto128.97 lbs
Taumaha Kupenga Wae o waho164.02 lbs

10. Pūtāhui me te Tautoko

ACiQ offers a comprehensive warranty for this heat pump system:

  • Wāhanga Pūtāhui: 7 tau
  • Pūtāhui Kōpeke: 12 tau

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ webpae.

Tuhinga e pa ana - B0DHFF2DKL

Preview ACiQ 9K-24K Paerewa Wera Pūnaha Rohe-kotahi: Tāuta me te pukapuka a te Kaipupuri
ACiQ 9K-24K Paerewa Wera Takitahi-kotahi Pūnaha Whakaritenga me te pukapuka a te Kaipupuri. Ko tenei aratohu e whakaatu ana i te whakaurunga, te mahi, te haumaru, me te tiaki mo nga hau hau ACiQ, tae atu ki nga tauira motuhake me nga korero whakamahana R454B.
Preview ACiQ Central Inverter Systems Tāuta Manual
He pukapuka whakaurunga matawhānui mo te ACiQ Central Inverter Air Conditioning me nga Pūnaha Puma Wea, e whakaatu ana i nga whakatupatotanga mo te haumaru, te paipa whakamahana, te whakaurunga o waho, te waea, nga tohu hiko, te rerenga hau, me nga tikanga whakahaere whakamatautau.
Preview ACiQ Te Kaihautu Rererangi me te Wera Tino Takiwa-kotahi te whakaurunga me te pukapuka a te rangatira.
Ko tenei pukapuka e whakarato ana i nga korero mo te whakaurunga, te mahi, me nga aratohu haumaru mo nga kaikawe hau e whakairihia ana e te pakitara ACiQ me te wera nui o te rohe kotahi, ka hipoki i nga tauira ACIQ-06W-HH-MD ma te ACIQ-24ZPL-HP230C.
Preview ACiQ Central Inverter Systems Pukapuka-a-Wai-Wae-Tautanga
Ko te pukapuka whakaurunga matawhānui mo nga ACiQ Central Inverter Systems nga waahanga o waho, e hipoki ana i nga waahi haumaru, te paipa whakamahana, te waea, te whakaurunga, me nga tikanga whakamatautau mo nga tauira penei i te ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB, me etahi atu.
Preview ACiQ Next Gen Ducted Heat Pump System: Aratohu Timata Tere mo te Waea Weawera
Ko tenei aratohu e whakarato ana i nga korero tino nui mo te hono me te waea hiko ki te ACiQ Next Gen Ducted Heat Pump System. Ka whakamohiohia nga whiringa hononga e taunaki ana me etahi atu hononga, tae atu ki nga tautuhinga whakahuri DIP me nga whirihoranga paraka aukati mo nga momo momo whakamaarama.
Preview ACiQ Essentials Mini-Split Air Handler & Condenser Tāuta me te pukapuka a te Kaipupuri
He pukapuka ā-ringa whānui mō te tāutanga me te whakamahi i te pukapuka ā-ringa mō ngā pūnaha ACiQ Essentials Mini-Split Air Handler me Condenser, e kapi ana i ngā mahi whakatūpato haumaru, te tautuhi i ngā wāhanga, te whakahaere mana mamao, ngā tikanga tāutanga, ngā whakamātautau, te tiaki, me te rapurongoā mō ngā tauira rerekē. Kei roto hoki i te pukapuka ā-ringa ngā mōhiohio nui e pā ana ki te mahi tiaki i ngā pūnaha e whakamahi ana i te hauhautanga mura R454B, e aro nui ana ki ngā kawa haumaru me te tutuki i ngā ture. Kua hangaia mō ngā kaiwhakauru ngaio me ngā kaiwhakamahi mutunga kia pai ai te whakahaere o ngā pūnaha papu wera ACiQ mini-split.