1. Kupu Whakataki
This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of the EJWFASCV Pneumatic Solenoid Valve, including the AG-3021-24VDC model and other valves in the series. Please read this manual thoroughly before using the product to ensure proper function and to prevent damage or injury. Keep this manual for future reference.
2. Nga korero haumaru
Always observe the following safety precautions to prevent personal injury and damage to the equipment.
- Ensure all power sources are disconnected before installation, maintenance, or troubleshooting.
- Verify that the operating pressure and voltage are within the specified limits for the valve.
- Mau taputapu whakamarumaru whaiaro (PPE) e tika ana penei i nga karaehe haumaru me nga karapu.
- Do not attempt to modify the valve. Unauthorized modifications can lead to malfunction and void the warranty.
- Install the valve in a clean, dry environment, free from excessive vibration or corrosive substances.
- Ensure proper grounding for electrical connections.
3. Hua Neke Atuview
The EJWFASCV Pneumatic Solenoid Valve is designed for controlling the flow of compressed air in various industrial and household applications. It features a robust construction for durability and ease of installation. The valve operates by an electrical signal, which actuates a solenoid to open or close the air path.

Whakaahua 1: A typical EJWFASCV Pneumatic Solenoid Valve, featuring a manual override lever for direct control. This image illustrates the general design of the valve series.

Whakaahua 2: Ki raro view of an EJWFASCV Pneumatic Solenoid Valve (model AC-7120 shown), displaying the various port connections and product labeling. Note that specific port configurations may vary by model.
Āhuatanga matua:
- Product durability: Sturdy valve body ensures a long service life.
- Te whānuitanga o nga tono: Suitable for household appliances, industrial equipment, and more.
- Convenient installation: Designed for easy installation and maintenance, offering reliable accuracy in various environments.
4. Tatūnga me te Tāuta
Follow these steps for proper installation of your pneumatic solenoid valve:
- Whakaritenga: Ensure the air supply is turned off and depressurized. Gather all necessary tools and fittings.
- Whakapiki: Securely mount the valve to a stable surface using appropriate fasteners. Ensure the valve is oriented correctly according to the desired flow direction.
- Pneumatic Connections: Connect the air supply lines to the designated inlet and outlet ports. Use thread sealant on all threaded connections to prevent leaks. Refer to the markings on the valve body for port identification (e.g., P for pressure, A/B for output, R/S for exhaust).
- Hononga Hiko: Connect the electrical wiring to the solenoid coil terminals. Ensure the voltage matches the valve's specifications (e.g., 24VDC for AG-3021-24VDC). Consult a qualified electrician if unsure.
- Whakamātautau: Once all connections are secure, slowly restore the air supply and electrical power. Test the valve's operation by applying the control signal. Check for any air leaks or electrical issues.
5. Nga Tohutohu Whakahaere
The EJWFASCV Pneumatic Solenoid Valve operates by receiving an electrical signal to control the flow of compressed air.
- Mahi Pūnoa: When the appropriate electrical voltage is applied to the solenoid coil, the valve will shift its internal mechanism, allowing air to flow through the designated ports. When the voltage is removed, the valve will return to its default position (typically closed or exhausting).
- Whakakore a-ringa: Many models, like the one shown in Figure 1, include a manual override lever or button. This allows for manual actuation of the valve for testing or emergency situations without electrical power. Use the manual override carefully and ensure the system is depressurized if necessary.
- Control System Integration: Integrate the valve into your control system (e.g., PLC, relay circuit) by connecting the solenoid's electrical terminals to the appropriate output. Ensure the control signal duration and frequency are compatible with the valve's specifications.
6. Tiaki
Regular maintenance helps ensure the longevity and reliable performance of your solenoid valve.
- Tirotiro: Periodically inspect the valve for any signs of wear, damage, or leaks. Check pneumatic connections for tightness and electrical wiring for integrity.
- Te horoi: Keep the valve and its surroundings clean. Dust and debris can affect performance. Use a soft, dry cloth for cleaning. Do not use harsh chemicals or solvents.
- Kounga rangi: Ensure the compressed air supply is clean and dry. Contaminants in the air can cause internal damage to the valve. Consider installing air filters and dryers upstream of the valve if not already present.
- Whakahinuhinu: Most modern pneumatic valves are designed for non-lubricated air or are pre-lubricated for life. Consult the manufacturer if lubrication is required for your specific model.
7. Te Raru
Tirohia te ripanga i raro nei mo nga take noa me o raatau otinga ka taea.
| Raruraru | Take pea | Rongoā |
|---|---|---|
| Valve does not actuate | No electrical power to solenoid; Incorrect voltage; Damaged solenoid coil; Low air pressure | Check power supply and connections; Verify voltage matches specifications; Replace solenoid coil; Check air supply and regulator |
| Air leak from valve | Loose pneumatic fittings; Damaged seals/gaskets; Internal contamination | Tighten fittings; Replace seals/gaskets; Clean valve internals (if serviceable) |
| Valve actuates slowly or weakly | Low air pressure; Contamination; Incorrect pilot pressure (if applicable) | Check air supply; Clean valve; Verify pilot pressure settings |
| Valve sticks in one position | Contamination; Mechanical obstruction; Damaged spring | Clean valve internals; Remove obstruction; Replace valve or internal components |
8. Whakatakotoranga
The following specifications apply to the EJWFASCV Pneumatic Solenoid Valve (Model AG-3021-24VDC). Specifications for other models in the series may vary.
| Huanga | Uara |
|---|---|
| Tau tauira | AG-3021-24VDC |
| Waitohu | EJWFASCV |
| Ahu mōkihi | 1.18 x 0.79 x 0.39 inihi |
| Taumaha Tūemi | 3.31 pauna |
| Huihuinga e hiahiatia ana | Kao |
| Te maha o nga wahi | 1 |
| Kaihanga | EJWFASCV |
9. Pūtāhui me te Tautoko
For warranty information and technical support, please refer to the product packaging or contact your point of purchase. Keep your purchase receipt as proof of purchase. For further assistance, you may also visit the official EJWFASCV webpaetukutuku, whakapā atu ranei ki ta raatau tari ratonga kaihoko.