GODIYMODULES BMS-6S-13S-25A-4.2V

GODIYMODULES Multi-Cell Li-ion Battery Management System (BMS) Module Instruction Manual

Model: BMS-6S-13S-25A-4.2V | Brand: GODIYMODULES

1. Kupu Whakataki

This instruction manual provides essential information for the safe and effective use of the GODIYMODULES Multi-Cell Lithium-ion Battery Management System (BMS) Module. This module is designed to protect lithium-ion battery packs ranging from 6 series (6S) to 13 series (13S) configurations, ensuring their longevity and safe operation by managing charging, discharging, and various protection functions.

The BMS module integrates features such as overcharge, over-discharge, overcurrent, and temperature protection, which are crucial for the stability and safety of high-energy density lithium-ion battery packs.

2. Nga korero haumaru

WARNING: Working with lithium-ion batteries and high-current circuits can be dangerous. Incorrect wiring or handling can lead to fire, explosion, or severe injury. Always exercise extreme caution.

  • Me whakarite kia tika, kia mau hoki ngā hononga katoa i mua i te whakamahi i te hiko.
  • Verify battery cell voltages and polarities before connecting to the BMS.
  • Do not short-circuit the battery pack or the BMS terminals.
  • Use appropriate personal protective equipment (PPE) such as safety glasses and insulated tools.
  • If you are unsure about any step, seek assistance from a qualified professional.
  • Keep the BMS module away from moisture and extreme temperatures.

3. Hua Neke Atuview

The GODIYMODULES BMS module is a compact circuit board designed for robust battery protection. It features multiple MOSFETs for power handling and a dedicated IC for cell voltage monitoring. The board supports a wide range of series configurations, making it versatile for various battery projects.

GODIYMODULES BMS Module with wiring harness

Whakaahua 3.1: Runga view of the GODIYMODULES BMS module with its included wiring harness.

Kati-ake runga view of the BMS circuit board

Whakaahua 3.2: Whakatata view of the BMS circuit board, showing components and connection points.

Āhuatanga matua:

  • Supports 6S to 13S Li-ion battery configurations.
  • Overcharge protection with a detection voltage of approximately 3.75V per cell.
  • Over-discharge protection with a detection voltage of approximately 2.1V per cell.
  • Overcurrent protection for both discharge (up to 66A peak) and charge (18A continuous).
  • Temperature protection with a control interface.
  • Low quiescent current (25µA).

4. Whakatakotoranga

Below are the detailed technical specifications for the GODIYMODULES BMS module. Please note that typical values are provided, and slight variations may occur.

Table of BMS protection item specifications

Figure 4.1: Detailed specifications for protection items, including voltage me nga paepae o naianei.

Table of BMS current and quiescent current specifications

Figure 4.2: Detailed specifications for continuous discharge/charge current and quiescent current.

Table 4.1: GODIYMODULES BMS Module Specifications
TawhāMinTikangaMaxWaeine
Over-charge Detection Voltage3.7253.753.775V
Neke atu i te utu Whakaora Voltage3.553.63.65V
Over-charge Protection Delay Time70010001300ms
Te Kitenga Tukunga-Nui Rawatage2.052.12.15V
Neke-tuku Whakaora Voltage2.252.32.35V
Over-discharge Protection Delay Time105140175ms
Over-discharge Protection Current546066A
Common-port Discharge Current (Continuous)18A
Over-discharge Current Protection Delay Time182430ms
Tiaki o naianei i runga i te utu324048A
Charging Current (Continuous)18A
Over-charge Current Protection Delay Time121620ms
Ko te Naianei Ataahua25µA
Parenga PaweraYes, with Temperature Control Interface
Parenga OrereCut off the load
Parenga iahiko-potoDisconnect Load to Release
Balancing FunctionKarekau
Ahu tinana55.13 x 31.57 x 6 mm (tata.)
Putanga Voltage (Nominal per cell)4.2 Volts (Charging termination voltage)
Te Tukunga Haere tonu o Naianei18 Amps
Tonu Tonu Whakatau Naianei18 Amps
Momo TuhonoXT60 (for main power, general recommendation)

Note on Voltage Discrepancy: The product title mentions "4.2V Lithium Li-ion Battery". This typically refers to the nominal maximum charging voltage per cell for standard Li-ion batteries. The "Over-charge Detection Voltage" of 3.75V (typical) refers to the voltage threshold at which the BMS initiates overcharge protection for an individual cell. The BMS is designed for 4.2V cells.

Note on Current Rating: The product title mentions "25A", while specifications list "Common-port Discharge Current (Continuous): 18A" and "Over-discharge Protection Current: 60A (peak)". The continuous discharge and charge current is 18A. The 25A likely refers to a maximum instantaneous or burst current, or a different model variant. For sustained operation, adhere to the 18A continuous rating.

Dimensional drawing of the BMS module

Figure 4.3: Dimensional drawing of the BMS module, showing key measurements in millimeters.

5. Tatūnga me te Tāuta

Careful wiring is critical for the correct and safe operation of the BMS. Follow these instructions precisely.

Wiring diagram for a 7S BMS configuration

Whakaahua 5.1: Example wiring diagram for a 7S battery pack. The principle applies to 6S-13S configurations.

Nga Waea Waea:

  1. Whakaritea te Pūhiko: Ensure all individual cells in your battery pack are balanced (have similar voltages) before connecting to the BMS. This is crucial for optimal performance and safety, especially since this BMS does not have an active balancing function.
  2. Connect Main Negative (B-): Connect the thickest negative wire from the BMS (labeled B-) to the main negative terminal of your entire battery pack (the negative terminal of the first cell).
  3. Ngā Arataki Taurite Hononga:
    • The BMS comes with a multi-pin connector and thin wires (balance leads). These wires must be connected to the positive terminals of each individual cell, starting from the first cell's positive terminal (which is also the negative of the second cell).
    • Connect the first balance lead (often labeled B1 or the lowest numbered wire) to the positive terminal of the first cell (Cell 1+).
    • Connect the second balance lead (B2) to the positive terminal of the second cell (Cell 2+), and so on.
    • The highest numbered balance lead (e.g., B13 for a 13S pack) connects to the main positive terminal of the entire battery pack (Cell 13+).
    • Hiranga: Connect the balance leads in ascending order of cell voltage. Incorrect order can damage the BMS.
    • For fewer than 13S: If your battery pack has fewer than 13 cells (e.g., 7S), connect the unused higher-numbered balance leads (e.g., B8 through B13 for a 7S pack) to the same point as the highest active balance lead (B7+ in a 7S example). This effectively bridges them to the pack's positive terminal.
  4. Connect Load Negative (P-): Connect the negative terminal of your load (e.g., motor controller, inverter) to the P- terminal on the BMS.
  5. Connect Charger Negative (C-): Connect the negative terminal of your battery charger to the C- terminal on the BMS.
  6. Main Positive Connection: The main positive terminal of the battery pack (Cell N+, where N is your series count) is typically connected directly to the positive terminals of both the load and the charger, bypassing the BMS for the positive path. This is a common-port BMS design.

Always double-check all connections with a multimeter before applying power. Verify that the voltage across each balance lead corresponds to the correct cell voltage.

6. Nga Tikanga Whakahaere

The GODIYMODULES BMS continuously monitors the voltage of each individual cell within the battery pack, as well as the overall current flowing in and out of the pack. When any monitored parameter exceeds or falls below its predefined safe threshold, the BMS will activate its protection mechanisms.

  • Tiaki Taumaha: Mena tetahi putau voltage rises above the overcharge detection voltage (e.g., 3.75V), the BMS will cut off the charging current to prevent cell damage. Charging will resume once the cell voltage drops to the recovery voltage.
  • Parenga-whakarerenga ake: Mena tetahi putau voltage drops below the over-discharge detection voltage (e.g., 2.1V), the BMS will cut off the discharge current to prevent irreversible cell damage. Discharge will resume once the cell voltage rises to the recovery voltage (typically by applying a charge).
  • Parenga Awa Tuwera: If the discharge or charge current exceeds the specified limits (e.g., 18A continuous, 60A peak discharge protection), the BMS will temporarily cut off the current to protect the battery and the BMS itself. This protection typically recovers automatically once the overload is removed.
  • Parenga Paemahana: The BMS monitors its own temperature or an external thermistor (if connected). If the temperature exceeds safe operating limits, it will cut off charge/discharge to prevent thermal runaway.

7. Te Raru

If you encounter issues with your BMS module, consider the following troubleshooting steps:

  • No Output Power / BMS Not Functioning:
    • Verify all wiring connections, especially the main B-, P-, C- terminals, and all balance leads. A single incorrect balance lead connection can prevent the BMS from operating.
    • Tirohia te voltage of each individual cell. If any cell is significantly overcharged or under-discharged, the BMS may be in a protected state.
    • Ensure the main battery pack voltage is within the operational range for your series configuration.
  • BMS Cuts Off Power Prematurely:
    • Awa nui: The load might be drawing more current than the BMS's continuous or peak rating. Reduce the load or ensure your application's current draw is within limits.
    • Runga-tuku: One or more cells might be reaching their low voltage threshold faster than others, indicating an unbalanced pack or a faulty cell. Check individual cell voltages.
    • Te pāmahana: The BMS or battery pack might be overheating. Ensure adequate ventilation.
  • Karekau te pākahiko i te utu:
    • Verify the charger is connected correctly to C- and the main positive.
    • Check if any cells are in an overcharged state, triggering overcharge protection.
    • Me whakarite kia tika te rōrahi o te rihitage and current output are compatible with your battery pack and BMS.

If issues persist after troubleshooting, contact the manufacturer for further assistance.

8. Tiaki

The GODIYMODULES BMS module is designed for reliable operation with minimal maintenance. However, following these guidelines can help ensure its longevity:

  • Kia ma me te maroke: Protect the BMS from dust, dirt, and moisture. Do not expose it to water or corrosive substances.
  • Tirotiro Hononga: Periodically check all wiring connections for tightness and signs of corrosion or damage. Loose connections can lead to poor performance or safety hazards.
  • Whakahau: Ensure the BMS and battery pack have adequate ventilation, especially during high-current operation, to prevent overheating.
  • Aukati i te kino o te tinana: Handle the board carefully to prevent physical damage to components or solder joints.

9. Pūtāhui me te Tautoko

For warranty information, technical support, or inquiries regarding the GODIYMODULES BMS module, please refer to the product's purchase platform or contact GODIYMODULES directly through their official channels. Please have your product model and purchase details ready when contacting support.

Tuhinga e pa ana - BMS-6S-13S-25A-4.2V

Preview Dyness PowerStone User Manual - 76.8kWh/100Ah Battery System
Comprehensive user manual for the Dyness PowerStone battery energy storage system, detailing product specifications, installation, configuration, and maintenance for the 76.8kWh/100Ah model.
Preview Mivvy ENERGY JBD BMS Wiring Diagrams for 7S to 21S Batteries
Detailed wiring diagrams and instructions for connecting Mivvy ENERGY JBD Battery Management Systems (BMS) to 7S, 8S, 9S, 10S, 11S, 12S, 13S, 14S, 15S, 16S, 17S, 18S, 19S, 20S, and 21S battery configurations. Includes steps for connecting battery terminals, balance leads, and charger/load.
Preview Dyness STACK100 User Manual: High-Voltage Pūnaha Rokiroki Pūhiko
Comprehensive user manual for the Dyness STACK100 high-voltage battery storage system, detailing product specifications, installation, maintenance, and safety guidelines for LiFePO4 battery modules.
Preview Pukapuka Kaiwhakamahi mō te Poari Tiaki Taurite Hohe o te Pūhiko Ritiumu JK-B2A8S-30P
He pukapuka kaiwhakamahi whānui mō te Poari Tiaki Taurite Hohe o te Pūhiko Ritiumu JIKONG JK-B2A8S-30P, e whakaatu ana i ngā āhuatanga, ngā whakatakotoranga, ngā mahi, ngā whakamāramatanga atanga, te tāutanga, me te whakahaere o te TAUIRA.
Preview Papa Tiaki Taurite Hohe Pūhiko Rikiora JIKONG JK-B2A24S-30P
He pukapuka tiaki whānui me te pukapuka kaiwhakamahi mō te Poari Tiaki Taurite Hohe Pūhiko Ritiumu JIKONG JK-B2A24S-30P. Ngā taipitopito o te hua kei runga ake neiview, ngā āhuatanga mahi, ngā aratohu kōwhiringa, ngā whakaahuatanga mahi taipitopito, ngā tawhā matua, ngā whakamāramatanga atanga, ngā tikanga tāutanga, me ngā tohutohu whakahaere APP. Tautokohia ngā matū me ngā whirihoranga pākahiko lithium.
Preview JK-BD4A24S-4P Lithium Battery Active Balancing Protection Board Manual Kaiwhakamahi
Kaiwhakamahi taipitopito me te pukapuka tiaki mo te JK-BD4A24S-4P Lithium Battery Active Balancing Protection Board na Chengdu Jikong Technology Co., LTD. Ka kapi te huaview, nga ahuatanga, te aratohu whiriwhiri, nga mahi, nga tawhā, te whakamaramatanga atanga, te whakaurunga, me te mahi APP.