1. Kupu Whakataki
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your TOSOT 34,000 BTU Cosmo Series Ducted Mini Split Air Conditioner. Please read this manual thoroughly before installation and use, and retain it for future reference. This system is designed for both cooling and heating, offering versatile climate control for various spaces.
2. Nga korero haumaru
Hiranga: Installation must be performed by certified technicians to ensure safety and system optimization. The ceiling structure must have adequate load-bearing capacity for the indoor unit.
- Momotuhia te hiko i mua i te mahi, te horoi ranei i te waahanga.
- Kaua e araia nga urunga hau, nga putanga ranei.
- Me whakarite te turanga tika kia kore ai e ru te hiko.
- Use only the specified refrigerant (R32) and follow all handling guidelines.
- Keep children away from the unit during operation and maintenance.
The unit is equipped with an R32 sensor for safety. Refer to the diagram below for visual reference.

3. Hua Neke Atuview
The TOSOT Cosmo Series Ducted Mini Split Air Conditioner provides efficient and discreet climate control. It features a concealed indoor unit designed for integration into ceiling structures and an outdoor condenser unit.

3.1 Nga waahanga matua
- Powerful Cooling & Heating: Delivers up to 1,324 CFM airflow with 6 fan speeds, including Turbo mode. Operates efficiently from -13°F to 122°F.
- Tiaki Pungao: Equipped with an inverter compressor and R32 refrigerant for optimized energy use. Features an energy-saving mode.
- High Static Pressure Design: Suitable for long-distance ducting and high-ceiling spaces, with adjustable external static pressure (0-1.106 inch WC).
- Tāuta Hangore: Default side return air can be converted to bottom return. Versatile placement of supply and return vents.
- Te Wai Whakaheke Aunoa: Built-in pump actively discharges condensation, reducing clogging risks and preventing ceiling leaks.
- Mana atamai: Includes a wired controller and supports app control for remote adjustments, timer, dehumidification, and sleep mode.
3.2 He aha kei roto i te Pouaka
Ensure all items are received before scheduling professional installation.

4. Tatūnga
Professional installation is required for this system. The following information provides an overview of key installation aspects.
4.1 Nga whakaaro mo te whakaurunga
- The indoor unit is designed for concealed installation within ceiling structures, saving wall and floor space.
- The unit supports flexible air return options (side or bottom) and multi-duct configurations.
- Ensure the ceiling has sufficient load-bearing capacity.



4.2 Waea Hiko
All electrical connections must comply with local and national electrical codes and be performed by a qualified electrician.
- Ensure all power sources are turned off before connecting any wires.
- Connect numbered wires from the indoor unit to the corresponding numbers in the outdoor unit's compartment.
- Connect the grounding wire (green to green).
- Connect power cables: black wire to letter N and red wire to letter L.
For a general understanding of wiring a mini-split unit, refer to the video below. Note that specific wiring diagrams for your TOSOT model should always be followed.
4.3 Pūnaha Whakawai
The built-in water pump enables upward pipe routing, saving ceiling space and actively discharging condensation. A float switch monitors water levels and triggers an alarm if too high, preventing leaks.

5. Nga Tohutohu Whakahaere
Your TOSOT Ducted Mini Split system offers multiple control options for optimal comfort.

5.1 Kaiwhakahaere Waea
The intuitive wired controller allows direct adjustment of settings such as temperature, mode, and fan speed.
5.2 Smart Control (App Control)
Utilize the dedicated app for remote adjustments and advanced features. This includes setting timers, activating dehumidification, and sleep mode. The app also supports Geo Location functions.
5.3 Aratau Mahi
- Matao: Provides powerful cooling with up to 1,324 CFM airflow.
- Whakawera: Delivers warmth efficiently, operating in conditions down to -13°F.
- Aratau Tiaki Pungao: Automatically adjusts cooling to maintain comfort while reducing power consumption.
- Whakakahoretanga: Reduces humidity levels in the space.
- Aratau Moe: Adjusts temperature for comfortable sleep and reduced energy use.
- Aratau Turbo: He tere te whakamatao, te whakamahana rānei ina hiahiatia he huringa pāmahana tere.


6. Tiaki
Ko te tiaki i nga wa katoa ka tino pai te mahi me te roa o to waahanga.
6.1 Tātari Tātari
Regularly clean or replace air filters as per the instructions in the full user manual to maintain air quality and system efficiency.
6.2 Whakapai Whanui
Wipe down the exterior of the indoor and outdoor units with a soft, damp kakahu. Kaua e whakamahi i nga matū kino me nga horoi horoi.
6.3 Drainage System Check
Periodically inspect the drainage system for any blockages or leaks. The built-in pump helps prevent issues, but regular checks are recommended.
7. Te Raru
If you encounter issues, refer to the following common troubleshooting tips. For complex problems, contact a certified technician.
| Raruraru | Take pea | Rongoā |
|---|---|---|
| Kāore te waeine e kā ana | Kāore he hiko, kua motu te kaiwawao hiko, kua iti te pākahiko o te mana mamao | Tirohia te pūtake hiko, tautuhi anō i te pūwehe, whakakapia ngā pākahiko mamao |
| He iti rawa te whakamahana/whakawera | Dirty air filters, blocked outdoor unit, incorrect mode setting, low refrigerant | Clean filters, clear obstructions, select correct mode, contact technician for refrigerant check |
| Haruru ohorere | Loose parts, fan obstruction, refrigerant flow noise (normal) | Check for loose parts or obstructions, if persistent or loud, contact technician |
| Te rerenga wai | Blocked drain pipe, improper installation | Check and clear drain pipe, ensure proper slope, contact technician for installation review |
8. Whakatakotoranga
| Āhuahira | Taipitopito |
|---|---|
| Waitohu | TOSOT |
| Momo Tauira | SU-COSMO36D/I;SU-COSMO36-230/O |
| Te Mana Matao | 34,000 Nga Waahanga Ngawha o Ingarangi |
| Te kaha | 3 Toni |
| Voltage | 230.0 V |
| Wattage | 9965 W |
| Taumata Haruru | 36 Decibels |
| Hunga Hua | 39.37 x 29.37 x 16.81 inihi |
| Taumaha Tūemi | 248 pauna |
| Momo Tāuta | Ritua Pūnaha |
| Nga waahanga motuhake | Fast Cooling, Heating & Cooling Function, Remote Controlled, WiFi Enabled |
| Tauwehenga Pungao o te Kaupeka (SEER) | 14 |
9. Pūtāhui
Warranty information is typically provided with your product documentation. Please ensure that installation is carried out by certified technicians, as improper installation may void the warranty. Keep your purchase receipt and installation records for warranty claims.
10. Tautoko
For technical assistance, troubleshooting beyond this manual, or to inquire about service, please contact TOSOT customer support. Refer to the contact information provided in your product packaging or visit the official TOSOT webpae.