1. Kupu Whakataki
The EARU Electric Single Phase Energy Meter (Model EARU-1006) is designed for accurate monitoring of electrical parameters in single-phase 220V, 80A systems. It provides real-time data for voltage (V), current (A), power (W), power factor (PF), frequency (Hz), and kilowatt-hour (kWh) consumption. This device assists in understanding energy usage and identifying potential inefficiencies in your electrical system.
2. Nga korero haumaru
- Ko te whakaurunga me mahi e tetahi tohunga hiko i runga i nga tikanga me nga ture hiko o te rohe.
- Ensure the main power supply is disconnected before installation or maintenance to prevent electric shock.
- Kaua e whakahaeretia te taputapu ki te ahua kua pakaru.
- This device is designed for indoor use in a dry environment. Avoid exposure to moisture or extreme temperatures.
- The maximum current rating is 80A. Do not exceed this limit.
3. Hua Neke Atuview
The EARU-1006 energy meter features a clear LCD display that shows various electrical parameters simultaneously. It is designed for DIN rail mounting, allowing for easy integration into standard electrical distribution boards.

Whakaahua 1: Mua view of the EARU Electric Single Phase Energy Meter, showing the LCD display with various electrical readings.

Whakaatu 2: Taipitopito view of the LCD display, illustrating the layout of voltage, current, power, frequency, power factor, and kWh readings.
4. Ihirangi mokete
Kei roto i te kete:
- 1 x EARU Electric Single Phase Energy Meter (Model EARU-1006)
5. Whakatakotoranga

Figure 3: Technical data table providing detailed specifications of the energy meter.
| Tawhā | Uara |
|---|---|
| Waitohu | EARU |
| Tauira | EARU-1006 |
| Whakatauhia Voltage | AC110V/220V (230 Volts) |
| Whakatauhia o naianei | 80A |
| Auautanga | 50/60Hz |
| Tikanga ine | ±1% / Class 1 |
| Whakamahi Hiko | <2W |
| Tāutatanga | 35mm DIN Rerewe |
| Te Mahana Mahi | -10°C ki te +55°C |
| Paemahana Rokiroki | -40°C ki te +70°C |
| Haumākū Mahi | 5% ki te 95% RH |
| Momo Whakaatu | LCD |
| Max kWh Record | 999999kWh |
| Hunga Hua | 10 x 5 x 10 cm |
| Taumaha Tūemi | 450 g |

Figure 4: Dimensional drawing of the energy meter, showing measurements in both millimeters and inches.
6. Tatūnga me te Tāuta
Hiranga: Me mohio kua momotuhia nga hiko katoa i mua i te whakaurunga.
- Whakapiki: The EARU-1006 is designed for 35mm DIN rail mounting. Snap the meter onto the DIN rail securely within your electrical panel.
- Waea waea: Refer to the wiring diagram below for correct connection. This is a single-phase, 2-wire direct connection meter.
- Connect the Live (L) input wire to the designated 'L In' terminal.
- Connect the Neutral (N) input wire to the designated 'N In' terminal.
- Connect the Live (L) output wire to the designated 'L Out' terminal.
- Connect the Neutral (N) output wire to the designated 'N Out' terminal.
- Whakahiko: Once all connections are secure and verified, restore power to the circuit. The LCD display should illuminate and begin showing readings.

Figure 5: Wiring diagram illustrating the correct connections for the single-phase energy meter.
7. Nga Tohutohu Whakahaere
The energy meter operates automatically once powered on. The LCD display continuously cycles through or shows multiple parameters simultaneously.
- Reading Parameters: The display shows Voltage (V), Current (A), Power (W), Power Factor (PF), Frequency (Hz), and Kilowatt-hour (kWh).
- kWh Reading: The meter records total kWh consumption. This reading is permanent and accumulates over time.
- kWh Reset: The meter features a manual reset function for the kWh reading. Consult the device's physical buttons or specific instructions on the meter itself for the reset procedure. Typically, a long press on a designated button (if present) will reset the temporary kWh value. The total kWh value is usually non-resettable.
8. Tiaki
- Te horoi: Whakamahia he kakahu ngohengohe, maroke hei horoi i te taha waho o te mita. Kaua e whakamahi i ngā kaihoroi whakakoi, i ngā whakarewa rānei.
- Tirotiro: Periodically inspect the wiring connections to ensure they are tight and free from corrosion.
- Taiao: Me whakarite kia noho tonu te taiao whakahaere i roto i nga awhe pāmahana me te haumākū kua tohua.
9. Te Raru
| Raruraru | Take pea | Rongoā |
|---|---|---|
| He waatea te whakaaturanga | Kāore he pūtake hiko; He hē te waea | Check power connections and ensure power is supplied. Verify wiring against the diagram. |
| Ko nga korero e he ana | Incorrect wiring; Faulty connection | Double-check all wiring connections. Ensure wires are securely fastened. |
| kWh not accumulating | No load connected; Meter malfunction | Ensure there is an active electrical load connected through the meter. If problem persists, contact support. |
10. Pūtāhui me te Tautoko
The EARU Electric Single Phase Energy Meter (Model EARU-1006) typically comes with a 1-year warranty from the date of purchase. Please retain your purchase receipt for warranty claims.
For technical support, troubleshooting assistance, or warranty inquiries, please contact your retailer or the manufacturer directly. Refer to the product packaging or manufacturer's webpae mo nga korero whakapiri.