Elitech DMG-2SE

He Pukapuka Tohutohu mō te Huinga Ine Mamati Elitech DMG-2SE

Model: DMG-2SE | Brand: Elitech

Kupu Whakataki

This manual provides comprehensive instructions for the safe and efficient operation, setup, and maintenance of the Elitech Digital Manifold Gauge Set, model DMG-2SE. This device is designed for precise measurement of pressure and temperature in HVAC, refrigeration, and air conditioning systems. Please read this manual thoroughly before use to ensure proper functionality and safety.

Nga korero haumaru

Ka mutu te huaview me nga Waehanga

The Elitech DMG-2SE is a digital manifold gauge designed for HVAC/R professionals, offering accurate pressure and temperature measurements. It features a high-definition LCD screen, intuitive controls, and robust construction for reliable performance.

Elitech Digital Manifold Gauge Set DMG-2SE with refrigerant hoses
Figure 1: Elitech Digital Manifold Gauge Set DMG-2SE with included refrigerant charging hoses.
Key features of Elitech DMG-2SE including 88 refrigerant types, real-time pressure, multi-unit toggle, observation window, refrigerant charge/recovery, 1% accuracy, rugged design, and 200H battery life.
Whakaatu 2: Neke Atuview of key features including support for 88 refrigerant types, real-time pressure and saturation temperature display, multi-unit toggle, observation window, refrigerant charge/recovery functions, ±1% accuracy, rugged design, and 200-hour battery life.
Diagram of Elitech DMG-2SE showing LCD display, control buttons, valve knobs, refrigerant hose connection ports, sight glass, battery compartment, information label, and hanging mount.
Figure 3: Labeled diagram of the DMG-2SE showing the LCD display, control buttons, valve knobs, refrigerant hose connection ports (1/4" SAE), sight glass, battery compartment, information label, and hanging mount.

Nga ngongo Refrigerant

The included refrigerant charging hoses are color-coded for easy identification and proper connection.

Three refrigerant charging hoses in red, yellow, and blue, each 59 inches long with 1/4 inch SAE screw threads.
Figure 4: The included 59-inch (1.5m) refrigerant charging hoses with 1/4" SAE screw threads.
Close-up of refrigerant hose connections, indicating red for high pressure, blue for low pressure, and yellow for refrigerant.
Figure 5: Color coding for refrigerant hoses: Red for high pressure, Blue for low pressure, and Yellow for refrigerant.

Whakatakotoranga

Tatūnga

  1. Tāuta Pūhiko: Open the battery compartment located on the back of the unit. Insert two AAA batteries, ensuring correct polarity (+/-). Close the compartment securely.
  2. Hiko Tuatahi: Patohia te mana hiko (U symbol) to turn on the device. The LCD screen will illuminate.
  3. Kōwhiringa Waeine: Use the "MODE" button to cycle through available measurement units (psi, kg/cm², kPa, MPa, bar, inHg for pressure; °C/°F for temperature). Select your preferred units by stopping on the desired option.
  4. Refrigerant Selection: Press the "MODE" button repeatedly until the refrigerant type (e.g., R134a) flashes on the display. Use the up/down arrow buttons to scroll through the list of supported refrigerants. Confirm your selection by pressing "MODE" again or by waiting a few seconds for the selection to auto-confirm.
  5. Zeroing the Pressure: Before connecting the gauge to any system, ensure it is at atmospheric pressure (not connected to any pressure source). Press the "ZERO" button to calibrate the pressure reading to zero. This ensures accurate measurements.

Nga Tohutohu Whakahaere

Te hono i nga ngongo

  1. Honoa te blue hose to the low-pressure service port of the HVAC/R system.
  2. Honoa te red hose to the high-pressure service port of the HVAC/R system.
  3. Honoa te yellow hose to the service port of your vacuum pump, refrigerant tank, or recovery machine.
  4. Ensure all connections are hand-tightened, then slightly snugged with a wrench to prevent refrigerant leaks.

Measuring Pressure and Temperature

  1. With the hoses connected to the system, slowly open the appropriate valve knobs on the manifold gauge to allow system pressure to reach the internal sensors.
  2. The LCD will display real-time pressure readings for both the high and low sides of the system.
  3. Simultaneously, the display will show the corresponding saturation temperatures (evaporation and condensation temperatures) for the currently selected refrigerant.
  4. The "PT" (Pressure-Temperature) mode shows pressure and saturation temperature. "Ev" (Evaporation) and "Co" (Condensation) indicate the saturation temperatures, while "PL" (Low Pressure) and "PH" (High Pressure) indicate the actual system pressures.
Close-up of the Elitech DMG-2SE digital display showing pressure and temperature readings for R134a refrigerant.
Whakaahua 6: Example of the digital display showing pressure and saturation temperature readings.

Refrigerant Charging/Recovery

The DMG-2SE provides accurate pressure readings essential for refrigerant charging and recovery processes. Always follow industry best practices and local regulations for these operations.

Te tiaki

Raparongoā

RaruraruTake peaRongoā
Kaore te taputapu i te hikoNga pākahiko kua mate, kua he ranei te whakaurungaWhakakapihia nga pākahiko, kia tika te polarity.
Ko nga panui pehanga kinoGauge not zeroed; Leaking connections; Incorrect refrigerant selectedZero the gauge before use. Check all hose connections for leaks. Verify the correct refrigerant type is selected.
Whakaatu whakaaturanga "Err"Sensor error or measurement out of rangePower off and restart the device. If the error persists, contact customer support.

Pūtāhui me te Tautoko

For detailed warranty information, technical support, or service inquiries regarding your Elitech Digital Manifold Gauge Set DMG-2SE, please contact Elitech customer service. Refer to the product packaging or the official Elitech webpae mo nga taipitopito whakapā me nga rauemi tautoko.

Elitech Webpae: www.elitech.com

Tuhinga e pa ana - DMG-2SE

Preview Pukapuka Kaiwhakamahi mō te Ine Mamati Atamai Elitech MS-100 PLUS
He pukapuka kaiwhakamahi whānui mō te Elitech MS-100 PLUS Smart Digital Manifold Gauge, e kapi ana i te whakaurunga hua, ngā tohutohu haumaru, me ētahi atuview, ngā mahi pātene, ngā tawhā hangarau, me ngā aratohu whakahaere tere mō ngā pūnaha whakamatao me te HVAC.
Preview Ine Mamati Elitech MS-100: Ngā Āhuatanga, te Mahi, me ngā Whakatakotoranga
He aratohu whānui mō te Elitech MS-100 Digital Manifold Gauge, e kapi ana i ōna āhuatanga, te tere o te whakahaere, ngā whakaritenga hangarau, ngā whakatūpato, me ngā taipitopito hua mō ngā pūnaha HVAC me te pouaka whakamātao.
Preview Pukapuka Kaiwhakamahi me ngā Whakatakotoranga mō te Ine Mamati a Elitech MS-800 Series
He pukapuka kaiwhakamahi whānui mō te taputapu manifold mamati Elitech MS-800 Series, e kapi ana i te whakaurunga hua, ngā aratohu haumaru, te tiaki taiao, ngā whakatakotoranga taipitopito, me ngā aratohu whakahaere tere mō ngā inenga pēhanga me te pāmahana, ngā whakamātautau pēhanga pupuri, me te utu hauhautanga mō ngā pūnaha HVAC me te pouaka whakamātao.
Preview Pukapuka Kaiwhakamahi mō te Ine Mamati a Elitech MS Series
Pukapuka kaiwhakamahi mō te ine ine matihiko Elitech MS Series, e kapi ana i te whakaahuatanga hua, whānui atu i teview, ngā mahi pātene, ngā whakatakotoranga, te aratohu tīmatanga tere, ngā mahi whakahaere, ngā tono atamai, me te tiaki.
Preview Elitech MS-100 Digital Manifold Gauge Manual
Te pukapuka a te kaiwhakamahi mo te Elitech MS-100 Digital Manifold Gauge, e whakaatu ana i ona ahuatanga, mahi, whakaritenga, me te tiaki.
Preview Elitech MS-100 Digital Manifold: Manual Kaiwhakamahi me nga Whakatakotoranga
Aratohu matawhānui ki te momo matihiko Elitech MS-100, e kapi ana i ona ahuatanga, i nga whakaritenga hangarau, i te mahi, i nga tohutohu haumaru, me te rapu raruraru. Akohia me pehea te whakamahi i te taputapu mo te inenga pehanga me te pāmahana, nga whakamatautau turuturu, nga tukanga korehau, me te takiuru raraunga me te taupānga Elitech Tools.