DAB 60231855

Pukapuka Tohutohu mō te Papu Porowhita DAB Evosta 2 40-70/130

Model: 60231855 | Brand: DAB

1. Kupu Whakataki me Nekeview

The DAB Evosta 2 is an electronic, low-energy consumption circulator pump designed for water circulation in various domestic heating and air conditioning systems. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Evosta 2 pump.

The Evosta 2 series combines the robustness of mechanical circulators with the advantages of electronic control. It features a synchronous permanent magnet motor, a frequency converter, and an efficiency index (EEI) of ≤ 0.18, ensuring high efficiency and reliability. Its compact design and comprehensive performance make it suitable for replacing older three-speed circulators.

DAB Evosta 2 Circulator Pump
Figure 1: DAB Evosta 2 Circulator Pump. This image shows the main unit with its green and black housing, control panel, and threaded connections.

2. Nga korero haumaru

Hiranga: Pānuihia ngā tohutohu haumaru katoa i mua i te tāutanga, i te whakahaerenga rānei. Ki te kore e whai i ēnei tohutohu, ka pāngia pea koe e te ru hiko, te ahi, te whara kino rānei.

  • Ko te whakaurunga me te tiaki me mahi e nga kaimahi whai mana anake.
  • Ensure the power supply is disconnected before performing any work on the pump.
  • The pump operates with hot liquids; allow it to cool before handling to prevent burns.
  • Protect the pump from moisture and direct water spray.
  • Do not operate the pump if it is damaged or if the electrical cable is frayed.
  • The pump is designed for clean, non-viscous, chemically neutral liquids. Do not use with flammable or corrosive liquids.

3. Whakaahuatanga Hua me nga ahuatanga

The Evosta 2 circulator pump is engineered for optimal performance and durability. Key features include:

  • Pūngao Pūngao: Equipped with a synchronous permanent magnet motor and frequency converter, achieving an EEI ≤ 0.18.
  • Hanganga pakari: Cast iron pump body with cataphoresis treatment, wet rotor motor, and ceramic shaft mounted on ceramic bushings lubricated by the pumped liquid.
  • Parenga Whakauru: Internal motor protection eliminates the need for external overload protection.
  • Mana hoa-kaiwhakamahi: A single sequential adjustment button on the control panel simplifies settings.
  • Urunga Tiaki: Direct access to the crankshaft for potential unlocking.
  • High Protection Rating: IPX5 tohu tiaki.
DAB Evosta 2 Features and Benefits
Whakaatu 2: Neke Atuview of Evosta 2 features, highlighting its energy efficiency (EEI ≤ 0.18) and 5-year warranty. The image also shows different models in the Evosta series.

Te papu casing is made of steel, with a technopolymer impeller. The rotor sleeve, stator sleeve, and closing flange are stainless steel. The thrust ring is graphite, and the sealing rings are EPDM. An air bleed plug made of brass is integrated.

DAB Evosta 2 Exploded View and Materials List
Whakaahua 3: Pahū view of the Evosta 2 pump with a corresponding list of materials for each component, illustrating the internal construction.

4. Tāutanga

Proper installation is crucial for the pump's performance and longevity. Follow these guidelines:

  • Tūnga Whakapuru: Install the pump with the motor axis horizontal.
  • Hononga Paipa: The Evosta 2 40-70/130 is equipped with 1" (G 1") threaded connections. The 1/2" designation refers to the thread intended for connection to 1" to 1/2" reduced female fittings. Verify compatibility with your existing pipes or fittings.
  • Tuku Hiko: Connect the pump to a single-phase 1 x 230 V ~ 50/60 Hz power supply. Ensure the electrical installation complies with local regulations.
  • Pūnaha Flushing: Before starting the pump, ensure the system is thoroughly flushed to remove any debris that could damage the pump.
  • Puring hau: The pump includes an integrated air bleed plug. After filling the system, open the plug to release any trapped air.

Refer to the dimensional drawings for precise measurements and connection details to ensure proper fitment within your system.

DAB Evosta 2 Dimensional Drawing
Figure 4: Dimensional drawing of the Evosta 2 40-70/130 pump, showing key measurements (in mm) and pump connection details (1" G thread).

5. Mahi

The Evosta 2 pump features a control panel on the electronic control device cover, allowing for easy adjustment of its functions. The pump offers nine setting options, selectable via the MODE button.

  • Kōwhiringa Tautuhinga: Press the MODE button to cycle through the available settings. The selected setting is indicated by six illuminated segments on the display.
  • Aratau Mahi: The pump supports various operating modes, typically including proportional pressure, constant pressure, and constant curve modes, to adapt to different system requirements.
DAB Evosta 2 Operating Modes and Settings
Figure 5: Diagram illustrating the different operating modes (Proportional Pressure, Constant Pressure, Constant Curve) and an example of model designation for the Evosta series.

Consult the specific icons or indicators on your pump's control panel to identify the active operating mode and adjust as needed for your heating or cooling system.

6. Tiaki

Regular maintenance ensures the long-term reliability and efficiency of your Evosta 2 pump.

  • Puring hau: Periodically check and, if necessary, open the integrated brass air bleed plug to release any air trapped in the pump. This prevents cavitation and ensures smooth operation.
  • Crankshaft Unlocking: In case of a blockage, the pump provides direct access to the crankshaft for manual unlocking. Refer to the technical diagrams for the exact location.
  • Te horoi: Keep the exterior of the pump clean and free from dust and debris. Do not use abrasive cleaners.
  • System Fluid: Ensure the pumped liquid remains clean and free of solid substances and mineral oils. Glycol content should not exceed 30%.
  • No Overload Protection Needed: Due to internal motor protection, no external overload protection is required.

7. Te Raru

If you encounter issues with your Evosta 2 pump, consider the following common problems and solutions:

  • Puma Kaore i te timata:
    • Tirohia te tuku hiko me te ara iahiko.
    • Ensure the pump is properly connected to the electrical mains.
    • Verify that the motor is not seized. Use the direct access to the crankshaft to attempt manual unlocking if necessary.
  • No Flow or Reduced Flow:
    • Check for air in the system. Bleed air using the integrated plug.
    • Inspect for blockages in the pipes or pump impeller.
    • Ensure valves in the system are open.
    • Verify the selected operating mode and setting are appropriate for the system's requirements.
  • Haruru rereke:
    • Noise can indicate air in the system. Purge air.
    • Check for foreign objects in the pump.
    • Ensure the pump is securely mounted and not vibrating excessively.

If problems persist after attempting these solutions, contact qualified service personnel or DAB customer support.

8. Whakatakotoranga Hangarau

TawhāUara
TauiraEvosta 2 40-70/130
Tau Waahanga Kaihanga60231855
Awhe Mahi0.4 – 3.6 m³/h with head up to 6.9 meters
Awhe Temperature Wai0 °C ki +110 °C
Te Mahi Mahi10 pae (1000 kPa)
Taurangi TiakiIPX5
Karaehe WehengaF
TāutatangaMotor axis horizontal
Tuku Hiko1 x 230 V ~ 50/60 Hz
Pumped LiquidClean, free of solids/mineral oils, non-viscous, chemically neutral, water-like (max 30% glycol)
Mahinga Tiana PumaMaka rino ki te maimoatanga cataphoresis
Motini Casing RauemiTe maitai
Rauemi ImpellerHangarau
Rauemi ShaftKarakia
Taumaha1.86 kg
Ahu mōkihi15 x 14 x 10 cm
DAB Evosta 2 Performance Curves and Data Table
Figure 6: Performance curves and detailed technical data table for various Evosta 2 models, including flow rate (Q) and head (H) values.

9. Pūtāhui me te Tautoko

The DAB Evosta 2 circulator pump comes with a 5-tau pūtāhui, ensuring peace of mind regarding its quality and durability. This warranty covers manufacturing defects under normal use conditions.

For technical assistance, warranty claims, or spare parts inquiries, please contact your authorized DAB dealer or customer support. When contacting support, please have your model number (60231855) and purchase date available.

Information regarding the availability of spare parts is not provided in the product data. Please consult your dealer for specific spare part availability.

Tuhinga e pa ana - 60231855

Preview Ngā Pūrere Hiko DAB Evosta Series: Ngā Whakatakotoranga Hangarau me ngā Raraunga
Ngā whakatakotoranga hangarau whānui, ngā āhuatanga, me ngā raraunga mō ngā porowhita hiko DAB Evosta 2, Evosta 3, Evosta 2 SAN, me Evosta 2 SOL mō te whakamahana whare, te whakamatao, me ngā pūnaha pūngao rā.
Preview Ngā Pūrere Hurihuri Makuku DAB BPH/BMH/DPH/DMH: Ngā Whakatakotoranga Hangarau me ngā Raraunga Mahi
Ngā whakatakotoranga hangarau taipitopito, ngā ānau mahi, ngā raraunga hiko, me ngā mōhiohio rauemi mō ngā papu porohita rotor mākū raupapa BPH, BMH, DPH, me DMH a DAB, i hangaia mō ngā pūnaha whakamahana me te hauhautanga.
Preview Ngā Papu Porowhita Raupapa DAB EVOSTA: Aratohu Tāutanga me te Tiaki
He aratohu whānui mō te tāuta me te tiaki i ngā papu porowhita DAB EVOSTA2, EVOSTA3, me EVOSTA2 SOL. Akohia ngā āhuatanga, ngā raraunga hangarau, te haumaru, me ngā momo whakahaere mō ngā pūnaha whakamahana me te whakatikatika whai hua.
Preview Rārangi Whānui o te DAB 2019: Ngā Otinga Hangarau Wai
Explore the comprehensive DAB General Catalogue 2019, featuring a wide range of water technology solutions including pumps for boosting, heating, waste water, swimming pools, and irrigation. Discover the innovative D.Connect system for remote control and smart building management.
Preview He Aratohu Tere mō te Papu Porowhita DAB EVOSTA2 SOL - Te Tāutanga me te Haumaru
He aratohu poto mō ngā papu porowhita DAB EVOSTA2 SOL raupapa, e whakaatu ana i ngā whakatūpato haumaru nui, te tāutangaview, ngā whakatakotoranga hua, me ngā mōhiohio whakapā mō ngā whakamahinga whakamahana whare me te pūngao rā.
Preview Pukapuka Tāutanga me te Tiaki mō te Pūwae Whakawhanui Maha-mahi DAB EVOPLUS SMALL
Kei roto i tēnei pukapuka ngā tohutohu taipitopito mō te tāutanga, te whakamahi, me te tiaki i te DAB EVOPLUS SMALL Multifunction Expansion Module, i hangaia hei whakarei ake i te mahi a ngā pūhiko hiko EVOPLUS SMALL.