Thank you for choosing the Elitech LDM-50D Laser Measure and MOT-270W Moisture Meter bundle. This comprehensive instruction manual provides detailed guidance on the safe and effective use of both devices. The LDM-50D offers precise distance, area, and volume measurements, while the MOT-270W accurately detects moisture levels in wood and building materials. Together, these tools enhance accuracy and efficiency for various home improvement, construction, and woodworking projects.
2. Nga korero haumaru
Please read and understand all safety instructions before operating these devices. Failure to follow these instructions may result in laser radiation exposure, electric shock, fire, or serious injury.
2.1 Whakatupato Haumaru Whanui
- Keep the devices away from children and unauthorized personnel.
- Do not operate the devices in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust.
- Store the devices in a dry, cool place when not in use.
- Do not attempt to modify or disassemble the devices. Repairs should only be performed by qualified service personnel.
- Use only specified batteries. Remove batteries if the device will not be used for an extended period.
2.2 Laser Safety (LDM-50D)
The Elitech LDM-50D is a Class 2 laser product. Observe the following precautions:
- Kaua e titiro tika ki te kurupae laser.
- Kaua e anga te kurupae laser ki nga tangata, kararehe ranei.
- A ape i te toronga kanohi tika ki te kurupae laser.
- Kaua e whakamahi i nga taputapu whatu (hei tauira, te karu, te telescope) ki view te kurupae laser.
- Ensure the laser is not accidentally activated.
2.3 Moisture Meter Safety (MOT-270W)
- The probes are sharp. Handle with care to avoid injury.
- Do not use the moisture meter on live electrical circuits or materials.
- Keep the probe cover on when not in use to protect the probes and prevent injury.
3. LDM-50D Laser Measure Overview
The Elitech LDM-50D is a compact and precise laser distance meter designed for quick and accurate measurements.
3.1 Nga waahanga matua
- Measurement Range: Up to 165 feet (50 meters)
- Accuracy: ±2mm (±1/16 inch)
- Measurement Functions: Single, Continuous, Area, Volume, Pythagorean (indirect)
- Whakaaturanga: Backlight LCD
- Data Storage: 99 measurements
- Durability: Dustproof & Drop-Resistant (IP54, 1m drop)
- Additional: Dual bubble levels for stability, Key sound feedback
3.2 Tahora Pūrere



4. MOT-270W Moisture Meter Overview
The Elitech MOT-270W is a pin-type moisture meter designed for quick and accurate moisture content detection in various materials.
4.1 Nga waahanga matua
- Measurement Principle: Electrical Resistance
- Accuracy: ±2% (Wood gear)
- Material Modes: 4 selectable wood types + building materials
- Functions: HOLD, Max/Min value tracking, Automatic calibration
- Display: Large anti-parallax display
- Power: Automatic shutdown after 10 minutes of inactivity
- Additional: Protective probe cover, Battery alert
4.2 Tahora Pūrere



5. Tatūnga
5.1 LDM-50D Laser Measure Battery Installation
- Kimihia te uhi o te wahanga pākahiko kei muri o te taputapu.
- Kiriata te uhi kia tuwhera.
- Insert two AAA batteries (not included) according to the polarity markings (+/-).
- Katia kia mau te uhi o te wahanga pākahiko.
5.2 MOT-270W Moisture Meter Battery Installation and Probe Preparation
- Kimihia te uhi o te wahanga pākahiko kei muri o te taputapu.
- Kiriata te uhi kia tuwhera.
- Insert two AAA batteries (not included) according to the polarity markings (+/-).
- Katia kia mau te uhi o te wahanga pākahiko.
- Remove the protective probe cover before use. Replace it after each use to prevent damage and ensure safety.
6. Operating Instructions: LDM-50D Laser Measure
6.1 Hiko / Whakaweto
- Hei whakakaha: Patohia te PĀNUI pātene. Ka whakahohe te laser.
- Hei whakaweto: Pēhi me te pupuri i te MATE/MAMA button for a few seconds. The device will also auto-power off after 180 seconds of inactivity.
6.2 Whiringa Unit
Pehia te UNIT button to cycle through measurement units: meters (m), feet (ft), and inches (in).
6.3 Measurement Reference Point
Pehia te Tohutoro button to switch the measurement reference point between the front edge and the rear edge of the device. An icon on the display will indicate the current reference point.
6.4 Te Ine i te Tawhiti Kotahi
- Whakatakotoria te rēseri ki te ūnga.
- Pehia te PĀNUI kotahi te paatene hei whakahohe i te laser.
- Pehia te PĀNUI button again to take the measurement. The result will be displayed.
6.5 Te Ine Tonu (Aroturuki)
- Pehia te Mahi button until the continuous measurement icon appears.
- Pehia te PĀNUI button. The device will continuously measure and display the current distance, as well as the maximum and minimum distances detected during the session.
- Perehi PĀNUI ano ranei MATE/MAMA kia mutu te inenga tonu.
6.6 Te Ine Rohe
- Pehia te Mahi button until the area measurement icon appears.
- Measure the first side (e.g., length) by pressing PĀNUI.
- Measure the second side (e.g., width) by pressing PĀNUIKa tatau aunoa te pūrere, ka whakaatu hoki i te horahanga.
6.7 Ine Rōrahi
- Pehia te Mahi button until the volume measurement icon appears.
- Measure the length, width, and height sequentially by pressing PĀNUI after each measurement. The device will automatically calculate and display the volume.
6.8 Pythagorean Measurement (Indirect Measurement)
This function allows indirect measurement of height or distance using the Pythagorean theorem.
- Pehia te Mahi button until the desired Pythagorean measurement icon appears (e.g., for height from two measurements, or height from three measurements).
- Follow the on-screen prompts to take the required measurements (e.g., hypotenuse, base). Ensure the device is held stable and level for accurate results.
- The calculated indirect measurement will be displayed.
6.9 Te Rokiroki me te Whakamau Raraunga
The LDM-50D can store up to 99 measurements.
- Ka tiakina aunoatia ngā inenga.
- Pehia te Maharahara button to enter memory mode. Use the arrow buttons (if available, or repeated presses of Memory/Function) to scroll through stored data.
- Perehi MATE/MAMA to exit memory mode.
7. Operating Instructions: MOT-270W Moisture Meter
7.1 Hiko / Whakaweto
- Hei whakakaha: Patohia te Mana pātene.
- Hei whakaweto: Pēhi me te pupuri i te Mana button. The device will also auto-power off after 10 minutes of inactivity.
7.2 Kōwhiringa Rawa
The MOT-270W has different modes for various materials to ensure accurate readings.
- Pehia te M (Aratau) button to cycle through the material groups (e.g., Wood Group A, B, C, D, Building Materials). Refer to the device's internal guide or a separate material chart for specific wood types corresponding to each group.
- Select the appropriate group for the material you are testing.
7.3 Te Whanganga
- Ensure the correct material group is selected.
- Carefully push the two measurement probes into the material surface. Ensure both probes penetrate the material for a stable reading.
- Te ōrau o te ihirangi makukutage ka whakaaturia ki te mata.
- Remove the probes from the material.
7.4 Mahi HOLD
Pehia te KAUPAPA button to freeze the current reading on the display. Press KAUPAPA again to release it and resume live readings.
7.5 Max/Min Value Tracking
The MOT-270W can track the maximum and minimum moisture values detected during a measurement session.
- I a koe e ine ana, pehia te SET button to cycle through normal reading, MAX, and MIN display modes.
- In MAX mode, the highest moisture reading recorded will be shown. In MIN mode, the lowest reading will be shown.
7.6 Whakariterite Aunoa
The MOT-270W features automatic calibration for reliable readings. To perform a quick check:
- Ensure the probes are not touching any material.
- Power on the device. It should display a low, stable reading (e.g., 0.0%). If not, ensure the probes are clean and undamaged.
8. Tiaki
8.1 Te horoi
- Wipe the device surfaces with a soft, damp kakahu. Kaua e whakamahi i nga kai horoi me nga whakarewa.
- For the MOT-270W, ensure the probes are clean and free of debris after each use.
8.2 Whakakapinga Pūhiko
- Ina puta te tohu o te pākahiko iti ki te whakaaturanga, whakakapi wawe i nga pākahiko.
- Refer to the "Setup" section for battery installation instructions.
- Whakakorehia nga pākahiko tawhito i runga i nga ture o te rohe.
8.3 Rokiroki
- Store both devices in a dry, cool environment, away from direct sunlight and extreme temperatures.
- For the MOT-270W, always replace the protective probe cover before storage.
- If storing for an extended period, remove the batteries from both devices to prevent leakage.
9. Te Raru
| Raruraru | Take pea | Rongoā |
|---|---|---|
| LDM-50D: Kaore te taputapu i te hiko. | Nga pākahiko kua mate, kua he ranei te whakaurunga. | Whakakapihia nga pākahiko, kia tika te polarity. |
| LDM-50D: Ko nga panui kaore i te tika, kaore ranei i te rite. | Unstable measurement, obstructed laser, incorrect reference point, reflective surface. | Ensure stable positioning, clear laser path, verify reference point, use a target plate for reflective surfaces. |
| LDM-50D: Ko te karere "Hapa" kei te whakaatu. | Measurement out of range, strong interference. | Measure within specified range, avoid strong light sources or electromagnetic interference. |
| MOT-270W: Kaore te taputapu i te hiko. | Nga pākahiko kua mate, kua he ranei te whakaurunga. | Whakakapihia nga pākahiko, kia tika te polarity. |
| MOT-270W: Inconsistent or zero readings. | Probes not fully inserted, damaged probes, incorrect material mode, probes touching metal. | Ensure probes are fully inserted, check probes for damage, select correct material mode, avoid metal objects. |
| MOT-270W: Display shows "Lo" or "Hi". | Moisture content is outside the measurable range. | The material is either extremely dry or extremely wet, beyond the device's limits. |
10. Whakatakotoranga
10.1 Elitech LDM-50D Laser Measure
| Tawhā | Uara |
|---|---|
| Awhe Ine | 0.05m - 50m (0.16ft - 165ft) |
| Tikanga ine | ±2mm (±1/16 inch) |
| Waeine ine | m / ft / in |
| Karaehe Taiaho | Te akomanga 2, <1mW |
| Momo Taiaho | 635nm |
| Rokiroki Raraunga | 99 roopu |
| Auto Laser Off | 30 hēkona |
| Auto Instrument Off | 180 hēkona |
| Te Waahi Mahi | 0°C ki te 40°C (32°F ki te 104°F) |
| Paemahana Rokiroki | -20°C ki te 60°C (-4°F ki te 140°F) |
| Tuku Hiko | 2 x AAA pākahiko (1.5V) |
| Ahu | (Refer to product for exact dimensions, typically compact) |
| Taumaha | (Refer to product for exact weight, typically lightweight) |
10.2 Elitech MOT-270W Moisture Meter
| Tawhā | Uara |
|---|---|
| Tikanga Ine | Ātete Hiko |
| Tikanga ine | ±2% (Wood gear) |
| Te Waahi Mahi | 0°C ki te 40°C (32°F ki te 104°F) |
| Te haumākū whakahaere | 20% RH ki te 90% RH |
| Auto Instrument Off | meneti 10 |
| Tuku Hiko | 2 x AAA pākahiko (1.5V) |
| Rōpū Rauemi | 4 Wood Groups + Building Materials |
11. Pūtāhui me te Tautoko
11.1 Nga Korero Whakaputanga
Elitech products are designed and manufactured to high-quality standards. For detailed warranty information, including coverage period and terms, please refer to the warranty card included with your product or visit the official Elitech webpae. Puritia to riirii hoko hei tohu mo te hoko mo nga kereme whakamana.
11.2 Tautoko Kiritaki
If you encounter any issues or have questions regarding the Elitech LDM-50D Laser Measure or MOT-270W Moisture Meter, please contact Elitech customer support. You can typically find contact information (phone, email, or support portal) on the official Elitech webte waahi kei roto ranei i te kohinga hua.