1. Kupu Whakataki
This manual provides essential information for the safe installation, operation, and maintenance of your PowMr Hybrid Solar Inverter 12000W. Please read this manual thoroughly before installation and operation to ensure optimal performance and safety. Keep this manual for future reference.
2. Nga korero haumaru
WARNING: This inverter generates high voltage. Installation and maintenance must be performed by qualified personnel only. Failure to follow these instructions may result in serious injury or death.
- Do not attempt to disassemble or repair the inverter yourself. Contact qualified service personnel.
- Ensure all wiring is correctly sized and installed according to local and national electrical codes.
- Disconnect all power sources (PV, battery, AC input) before performing any maintenance or wiring.
- Install the inverter in a well-ventilated, dry, and cool environment, away from flammable materials.
- Me whakarite tika te turanga o te inverter.

Figure 2.1: The inverter features comprehensive protection against over/under voltage, overload, short circuit, over-temperature, and anti-backfeed.
3. Hua Neke Atuview
3.1 Nga waahanga matua
- Putanga: 12000W continuous (24000W peak), 120/240Vac split-phase output.
- Tāuru PV: Maximum 6600W PV input power, 500V DC maximum, 22A. PV starting voltage: ≥150V.
- MPPT Charger: Dual 100A MPPT chargers, max 200A charge current.
- Hototahitanga Pūhiko: Supports 48V Li-ion, Lead-Acid, and user-defined battery types.
- Battery-Less Mode: Capable of powering loads directly from PV/AC without a battery connected.
- Mahi Whakarara: Supports up to 6 units in parallel for increased power output.
- Aroturuki: Large LCD display, dynamic flow diagrams, and optional WiFi for remote monitoring via mobile app.
- Tauranga Whakawhitiwhiti: RS485, CAN, USB interfaces for integration with battery BMS, generator ATS, and smart home systems.

Whakaatu 3.1: Neke Atuview of the 12KW Split-Phase Hybrid Solar Inverter's main features and capabilities.
3.2 Product Appearance and Components

Whakaahua 3.2: Mua me te taha view of the inverter with labeled components.
- Whakaaturanga LCD
- Tohu LED
- Touchable Key
- ON / WIKI Whakawhiti Rocker
- PV INPUT (1/1)
- WHAKATOKANGA PAPA (+)
- WHAKATOKANGA PAPA (-)
- Whakapā maroke
- CAN/RS485 Port
- Tauranga WIFI
- Tauranga USB-B
- Tiwiri Whenua
- AC OUT (L1+L2+N)
- AC IN (L1+L2+N)
- AC INPUT Breaker
- Tauranga Whakawhitiwhiti Whakarara
4. Tatūnga me te Tāuta
4.1 Te Wetewete me te Tirotiro
Upon receiving the inverter, carefully unpack it and inspect for any shipping damage. Ensure all components listed in the package contents are present:
- Solar inverter unit
- Taura korero whakarara
- 2 × battery terminal lugs
- 2 × M5 tīwiri
- pukapuka kaiwhakamahi
Note: WiFi module, batteries, adapters, solar/battery wires/cables are excluded and require additional purchase if needed.
4.2 Whakapiki i te Inverter
The inverter is designed for indoor (IP20) installation. Choose a mounting location that is:
- Vertical, on a solid surface capable of supporting the inverter's weight (approximately 27kg / 59.5lbs).
- He pai te hauhautanga kia taea ai te marara te wera.
- Protected from direct sunlight, moisture, and dust.
- He waatea mo te waea me te tiaki.
4.3 Hononga Waea
All wiring must comply with local electrical codes. Use appropriate wire gauges for all connections.
- Whakapapa: Connect the grounding screw (12) to a reliable earth ground.
- Hononga Pūhiko: Connect the 48V battery bank to the BAT INPUT (+) (6) and BAT INPUT (-) (7) terminals. Ensure correct polarity.
- Tāuru PV: Connect the solar panel array to the PV INPUT (1/1) (5) terminals. Observe correct polarity and ensure PV voltage is within specified limits (Max 500V DC, starting voltage ≥150V). Use 10AWG PV wire.
- Tāuru AC: Connect the utility grid or generator AC input to the AC IN (L1+L2+N) (14) terminals.
- Huaputa AC: Connect your loads to the AC OUT (L1+L2+N) (13) terminals. The inverter provides 120/240Vac split-phase output.
- Parallel Communication (Optional): If installing multiple inverters in parallel, connect the Parallel Communication Port (16) between units using the provided cable.
- Ētahi atu Hononga: Utilize RS485, CAN, USB, and dry contact ports (8, 9, 10, 11) for external communication and control as needed.

Whakaahua 4.1: Example of multiple inverters connected in parallel. Professional guidance is required for actual connections.

Figure 4.2: The inverter supports various 48V battery systems, including battery-less operation.
5. Nga Tohutohu Whakahaere
5.1 Kei te Hiko / Weto
- Me whakarite kia mau, kia tika hoki nga hononga waea katoa.
- Switch on the battery breaker, then the PV breaker.
- Flip the ON/OFF Rocker Switch (4) to the 'ON' position.
- Switch on the AC INPUT Breaker (15).
- To power off, reverse the sequence: AC INPUT Breaker off, ON/OFF Rocker Switch off, PV breaker off, battery breaker off.
5.2 Whakaaturanga LCD me nga Tautuhinga
The large LCD display (1) provides real-time energy visualization and system status. Use the touchable keys (3) to navigate menus and adjust settings. Refer to the detailed settings section in the full user manual for specific parameter configurations, including:
- Battery charging parameters (voltage, nāianei)
- Putanga voltage me te auau
- Operating modes (e.g., Solar First, Utility First, Battery First)
- Time-of-Use (TOU) control for smart charging/discharging
5.3 Battery-Less Mode
The inverter supports battery-less operation, allowing it to power loads directly from solar PV and/or AC input without a connected battery. This mode is useful for specific applications or during battery maintenance. Ensure proper configuration through the LCD settings.
6. Tiaki
Ko te tiaki i nga wa katoa ka mau te roa me te mahi tino pai o to kaihurihuri.
- Te horoi: Periodically clean the inverter's exterior and ventilation openings to prevent dust buildup, which can impede cooling. Use a dry, soft cloth.
- Hononga: Tirohia ngā hononga hiko katoa i ia tau mō te piripono me ngā tohu o te waikura. Whakapiritia anō mēnā e tika ana.
- Taiao: Me whakarite kia noho tonu te taiao whakaurunga i roto i nga awhe pāmahana me te makuku.
- Pūmanawa: Tirohia te kaihanga website for any available firmware updates. Firmware updates can improve performance and address known issues.
WARNING: Always disconnect all power sources before performing any cleaning or inspection.
7. Te Raru
Kei roto i tēnei wāhanga ngā otinga mō ngā take noa. Mō ngā raruraru kāore i te rārangihia i konei, whakapā atu ki te tautoko kiritaki.
| Raruraru | Take pea | Rongoā |
|---|---|---|
| Inverter does not power on | Kāore he hononga pākahiko, he iti rānei te kaha o te pākahikotage; DC breaker off; ON/OFF switch off. | Tirohia nga hononga pākahiko me te voltage; ensure DC breaker is on; turn ON/OFF switch to 'ON'. |
| Kaore he putanga AC | Overload; short circuit; AC output breaker tripped; inverter fault. | Reduce load; check for short circuits; reset AC output breaker; check LCD for error codes. |
| PV input not charging batteries | PV voltage too low or too high; PV polarity reversed; PV breaker off; MPPT fault. | Tirohia te PV voltage and polarity; ensure PV breaker is on; check LCD for PV error codes. |
| Unstable output in parallel mode | Incorrect parallel communication wiring; mismatched firmware versions; incompatible settings. | Ensure only one parallel communication cable is used between units. Verify all inverters have the same, latest firmware version. Check parallel settings on each inverter. Contact support if issues persist. |
| Inverter displays error code | Internal fault; external condition (e.g., over-temperature, over-voltagme). | Refer to the full manual's error code section for specific meanings and solutions. Address environmental conditions if applicable. |
8. Whakatakotoranga
| Tawhā | Uara |
|---|---|
| Ingoa Tauira | BI-POW-SunSmart 12KP |
| Ko te Mana Whakaputa I Whakatauria | 12000W (12KW) |
| Te Mana Puke | 24000W |
| Whakatauranga Putanga Voltage | 120/240Vac (Split-Phase/Single-Phase) |
| Pūhiko Voltage | 48V |
| Te Mana Whakauru PV Morahi | 6600W |
| Morahi PV Whakauru Voltage | 500V DC |
| Morahi PV Whakauru Naianei | 22A |
| PV Starting Voltage | ≥150V |
| Iahiko Utu MPPT | Dual 100A (Max 200A total) |
| Max. Mains/Generator Charging Current | 120A |
| Tauranga Whakawhitiwhiti | RS485, CAN, USB |
| Ahu (L×W×H) | 24.41 × 17.52 × 5.12 inihi (62 × 44.5 × 13 cm) |
| Taumaha | 59.5 lbs (27 kg) |
| Whakatauranga Tiaki | IP20 (Whakamahinga o roto) |
9. Pūtāhui me te Tautoko
For warranty information, please refer to the documentation provided with your purchase or contact PowMr customer service. For technical support, troubleshooting assistance, or inquiries regarding parts and service, please visit the official PowMr webpaetukutuku, whakapā atu ranei ki o raatau hongere tautoko kaihoko.
Rauemi ipurangi:
- PowMr Store on Amazon: Visit PowMr Store





